MadgeTech VFC2000 without Glycol Bottle Vaccine Temperature Monitoring System

Model: VFC2000 without Glycol Bottle | Order No: 902311-00

MadgeTech VFC2000 without Glycol Bottle Vaccine Temperature Monitoring System

Model: VFC2000 without Glycol Bottle | Order No: 902311-00

Designed to satisfy all CDC and VFC requirements and provides precise, continuous temperature monitoring and validation for temperatures as low as -148°F (-100°C).

Designed to satisfy all CDC and VFC requirements and provides precise, continuous temperature monitoring and validation for temperatures as low as -148°F (-100°C).

Your Price $199.00 USD
Availability 2 to 3 Weeks
Quantity

MadgeTech VFC2000 without Glycol Bottle Specifications

Specifications
Memory 16,128 readings (all channels enabled)
Reading Rate 1 reading every second up to 1 reading every 24 hours
Cold Junction Compensation Automatic based on internal channel
Battery Life 3 years typical at 1 minute reading rate
Material ABS Plastic
Dimensions 3.0 x 3.5 x 0.95" (76.2 x 88.9 x 24.1 mm) - Data logger only
Operating Environment -4 to +140°F (-20 to +60°C), 0% RH to 95% RH non-condensing
Required Interface Package USB to Mini USB Cable
Weight 1.1250 lbs
Baud Rate 250,000
Internal Channel Temperature Sensor Semiconductor
Internal Channel Temperature Range -4 to +140°F (-20 to 60°C)
Internal Channel Temperature Resolution 0.18°F (0.01°C)
Internal Channel Temperature Calibrated Accuracy ±0.5°C (0 to +50°C)
Remote Channel Temperature Sensor Type K Thermocouple (Included)
Remote Channel (Thermocouple) Temperature Range -148 to +176°F (-100 to +80°C)
Remote Channel (Glycol Bottle) Temperature Range -58 to +176°F (-50 to +80°C)
Remote Channel Temperature Resolution 0.18°F (0.1°C)
Remote Channel Temperature Calibrated Accuracy ±0.5°C
Click here for complete specifications on the MadgeTech VFC2000 without Glycol Bottle

What's included with the MadgeTech VFC2000 without Glycol Bottle

  • MadgeTech VFC2000 without Glycol Bottle Vaccine Temperature Monitoring System

MadgeTech VFC2000 without Glycol Bottle Specifications

Specifications
Memory 16,128 readings (all channels enabled)
Reading Rate 1 reading every second up to 1 reading every 24 hours
Cold Junction Compensation Automatic based on internal channel
Battery Life 3 years typical at 1 minute reading rate
Material ABS Plastic
Dimensions 3.0 x 3.5 x 0.95" (76.2 x 88.9 x 24.1 mm) - Data logger only
Operating Environment -4 to +140°F (-20 to +60°C), 0% RH to 95% RH non-condensing
Required Interface Package USB to Mini USB Cable
Weight 1.1250 lbs
Baud Rate 250,000
Internal Channel Temperature Sensor Semiconductor
Internal Channel Temperature Range -4 to +140°F (-20 to 60°C)
Internal Channel Temperature Resolution 0.18°F (0.01°C)
Internal Channel Temperature Calibrated Accuracy ±0.5°C (0 to +50°C)
Remote Channel Temperature Sensor Type K Thermocouple (Included)
Remote Channel (Thermocouple) Temperature Range -148 to +176°F (-100 to +80°C)
Remote Channel (Glycol Bottle) Temperature Range -58 to +176°F (-50 to +80°C)
Remote Channel Temperature Resolution 0.18°F (0.1°C)
Remote Channel Temperature Calibrated Accuracy ±0.5°C
Click here for complete specifications on the MadgeTech VFC2000 without Glycol Bottle

What's included with the MadgeTech VFC2000 without Glycol Bottle

  • MadgeTech VFC2000 without Glycol Bottle Vaccine Temperature Monitoring System