The Light101A is a compact, light data logger equipped with a built-in light sensor that monitors and records the occurrence and duration of light exposure.
The Light101A is a compact, light data logger equipped with a built-in light sensor that monitors and records the occurrence and duration of light exposure.
With a user-programmable reading rate of up to 1 reading per second, a 3-year battery life, and the ability to store over 400,000 readings, the Light101A is perfectly suited for long-term monitoring. This self-contained device does not require connection to a relay or switch, making it easy to deploy and retrieve without disrupting its setup.
The Light101A is fully compatible with the latest MadgeTech 4 Software, which simplifies starting, stopping, and downloading data. The software provides graphical, tabular, and summary data for detailed analysis and can display results in customizable engineering units.
Features
Applications
The Light101A data logger is equipped with an integrated light sensor designed to monitor and record the occurrence and duration of light availability, capturing detailed photoperiod data. This standalone unit simplifies deployment and data gathering by autonomously detecting light changes without the need for external connections to switches or relays.
This data logger is particularly useful in a variety of industries and applications, such as agricultural studies for optimizing plant growth cycles and environmental monitoring to study the effects of natural light on ecosystems. The Light101A also excels in building management, helping to analyze and enhance energy efficiency through controlled lighting studies. Additionally, it is valuable in zoological research, where understanding the impact of light on animal behaviors is crucial. This device replaces traditional manual monitoring methods, providing reliable and automatic documentation of light patterns.
MadgeTech 4 Software Features
Sensor Type | Digital |
Start Modes | Immediate start Delay start up to 18 months Multiple pushbutton start/stop |
Stop Modes | Manual through software Timed (specific date and time) |
Multiple Start/Stop Mode | Start and stop the device multiple times without having to download data or communicate with a PC. |
Real Time Recording | May be used with PC to monitor and record data in real time |
Password Protection | An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password |
Memory | 465,578 readings; software configurable memory wrap |
Wrap Around | Yes |
Reading Rate | 1 reading every 1 second up to 1 reading every 24 hours |
Engineering Units | Native measurement units can be scaled to display measurement units of another type such as on/off, open/closed and more |
LED Functionality | Green LED Blinks: 10 seconds to indicate logging and 15 seconds to indicate Delay or Manual Start Mode - Standby (waiting to start) Red LED Blinks: 10 seconds to indicate low battery and/or full memory |
LEDs | 2 status LEDs |
Calibration | Digital calibration through software |
Calibration Date | Automatically recorded within device |
Battery Type | 3.6 V lithium battery included; user replaceable |
Battery Life | 3 years typical, dependent upon frequency and duty cycle |
Time Accuracy | ±1 minute/month at 25°C (77°F) (Stand alone mode) |
Computer Interface | USB (interface cable required); 115,200 baud |
Operating System Compatibility | Windows XP SP3 or later |
Software Compatibility | Standard Software version 4.2.25.16 or later Secure Software version 4.2.24.16 or later |
Operating Environment | -40°C to +80°C (-40°F to +176°F) 0% RH to 95% RH non-condensing |
Dimensions | 1.4 in x 2.1 in x 0.6 in (35 mm x 54 mm x 15 mm) |
Weight | 0.8 oz (24 g) |
Material | Polycarbonate |
Approvals | CE |
Click on a category to view a selection of compatible accessories with the MadgeTech Light101A Ambient Light Data Logger.
Sensor Type | Digital |
Start Modes | Immediate start Delay start up to 18 months Multiple pushbutton start/stop |
Stop Modes | Manual through software Timed (specific date and time) |
Multiple Start/Stop Mode | Start and stop the device multiple times without having to download data or communicate with a PC. |
Real Time Recording | May be used with PC to monitor and record data in real time |
Password Protection | An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password |
Memory | 465,578 readings; software configurable memory wrap |
Wrap Around | Yes |
Reading Rate | 1 reading every 1 second up to 1 reading every 24 hours |
Engineering Units | Native measurement units can be scaled to display measurement units of another type such as on/off, open/closed and more |
LED Functionality | Green LED Blinks: 10 seconds to indicate logging and 15 seconds to indicate Delay or Manual Start Mode - Standby (waiting to start) Red LED Blinks: 10 seconds to indicate low battery and/or full memory |
LEDs | 2 status LEDs |
Calibration | Digital calibration through software |
Calibration Date | Automatically recorded within device |
Battery Type | 3.6 V lithium battery included; user replaceable |
Battery Life | 3 years typical, dependent upon frequency and duty cycle |
Time Accuracy | ±1 minute/month at 25°C (77°F) (Stand alone mode) |
Computer Interface | USB (interface cable required); 115,200 baud |
Operating System Compatibility | Windows XP SP3 or later |
Software Compatibility | Standard Software version 4.2.25.16 or later Secure Software version 4.2.24.16 or later |
Operating Environment | -40°C to +80°C (-40°F to +176°F) 0% RH to 95% RH non-condensing |
Dimensions | 1.4 in x 2.1 in x 0.6 in (35 mm x 54 mm x 15 mm) |
Weight | 0.8 oz (24 g) |
Material | Polycarbonate |
Approvals | CE |
Click on a category to view a selection of compatible accessories with the MadgeTech Light101A Ambient Light Data Logger.