Measure and store up to 32,000 temperature readings with this vaccine kit, capable of taking measurements from -130 to 104°F (-90 to 40°C). This kit comes with a dual-channel temperature recorder, two external probes, two buffer bottles, a wall mount bracket, and a calibration certificate.
Measure and store up to 32,000 temperature readings with this vaccine kit, capable of taking measurements from -130 to 104°F (-90 to 40°C). This kit comes with a dual-channel temperature recorder, two external probes, two buffer bottles, a wall mount bracket, and a calibration certificate.
See if temperature excursions have occurred at a glance with this vaccine kit, designed to show the current day and up to the previous 29 days. Additionally, this kit features a built-in alarm if temperature readings are outside pre-set limits.
Features
Applications
External Temperature Sensor Measurement Range | -130 to 104°F (-90 to 40°C) |
Temperature | Operating: -22 to 140°F (-30 to 60°C ), 0 to 99% RH (Non-condensing) Storage: 32 to 104°F (0 to 40°C) |
Rated Temperature Reading Accuracy | Better than ±32.9°F (±0.5°C) for -4 to 50°F (-20 to 10°C) Better than ±33.26°F (±0.7°C) for -58 to -4°F (-50 to -20°C) and 50 to 86°F (10 to 30°C) Better than ±33.8°F (±1°C) for -112 to -58°F (-80 to -50°C) and 86 to 104°F (30 to 40°C) Better than ±35.24°F (±1.8°C) for -130 to -112°F (-90 to -80°C) |
Sensor Reaction Time | Typically less than 2 minutes (T90) in moving air (1 m/s) for ST10S type probe |
Rated Temperature Reading Resolution | Better than 0.2°F (0.1°C) for measurements -112 to 50°F (-80 to 10°C) Better than 0.4°F (0.2°C) for measurements 50 to 68°F (10 to 20°C) and -130 to -112°F (-90 to -80°C) Better than 0.5°F (0.3°C) for measurements 68 to 86°F (20 to 30°C) Better than 0.9°F (0.5°C) for measurements 86 to 104°F (30 to 40°C) LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
Probe | Connectivity: Up to 2 Compatibility: All ST10 precision thermistor external probes can be interchangeably connected to the UTREL30-16 |
Recording Capacity | 32,000 total log memory Provides 16,000 temperature readings per channel Day summary statistics memory (For display on LCD): Up to 30 days of minimum/maximum/duration and alarm trigger statistics |
Sampling Interval | Configurable from 30 seconds to 18 hours (Typically 5 minute logging) |
Logging Start Options | Push button start (With configurable start delay from 1 minute to 72 hours) or specific date and time |
Alarms | Up to 6 individually configurable alarms for each channel Possible to set alarms separately for Channel 1 and Channel 2 |
Download Time | Typically with full memory (32,000 readings) in less than 20 seconds |
Environmental | IP61 (When vertically mounted or hung with USB dust-cap in place) |
Real Time Clock | Built-in real time clock Rated accuracy ±25 ppm at 77°F (25°C), equivalent to 2.5 seconds/day ↵Rated temperature coefficient is -0.034 ±0.006 ppm/°C (I.e typically ± 0.00294 seconds/day/°C) |
Standard Remote Probe Cable Lengths | Standard: 1.5 m (4’11") Extended: 3 m (9’10"), recommended maximum |
Remote Probe Cable Type | PTFE (FDA food contact rated) coaxial |
Connection Interface | USB 2.0/micro USB socket |
Case Material | Polycarbonate |
Power | Source: 5 V via micro USB socket or two 1.5 V AAA batteries. CR2032 LiMnO2 coin cell (backup logging function only) Life: AAA battery up to 12 months - if unit is operated without power supply |
Dimensions | 0.7 x 2.83 x 5.55" (18 x 72 x 141 mm) |
Weight | 0.34 lbs (158 g) with AAA batteries, 0.29 lbs (132 g) excluding probe and AAA batteries |
Click on a category to view a selection of compatible accessories with the LogTag UTREL30-16 Kit-2 Vaccine Kit with two external probes, -130 to 104°F, dual-channel.
External Temperature Sensor Measurement Range | -130 to 104°F (-90 to 40°C) |
Temperature | Operating: -22 to 140°F (-30 to 60°C ), 0 to 99% RH (Non-condensing) Storage: 32 to 104°F (0 to 40°C) |
Rated Temperature Reading Accuracy | Better than ±32.9°F (±0.5°C) for -4 to 50°F (-20 to 10°C) Better than ±33.26°F (±0.7°C) for -58 to -4°F (-50 to -20°C) and 50 to 86°F (10 to 30°C) Better than ±33.8°F (±1°C) for -112 to -58°F (-80 to -50°C) and 86 to 104°F (30 to 40°C) Better than ±35.24°F (±1.8°C) for -130 to -112°F (-90 to -80°C) |
Sensor Reaction Time | Typically less than 2 minutes (T90) in moving air (1 m/s) for ST10S type probe |
Rated Temperature Reading Resolution | Better than 0.2°F (0.1°C) for measurements -112 to 50°F (-80 to 10°C) Better than 0.4°F (0.2°C) for measurements 50 to 68°F (10 to 20°C) and -130 to -112°F (-90 to -80°C) Better than 0.5°F (0.3°C) for measurements 68 to 86°F (20 to 30°C) Better than 0.9°F (0.5°C) for measurements 86 to 104°F (30 to 40°C) LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
Probe | Connectivity: Up to 2 Compatibility: All ST10 precision thermistor external probes can be interchangeably connected to the UTREL30-16 |
Recording Capacity | 32,000 total log memory Provides 16,000 temperature readings per channel Day summary statistics memory (For display on LCD): Up to 30 days of minimum/maximum/duration and alarm trigger statistics |
Sampling Interval | Configurable from 30 seconds to 18 hours (Typically 5 minute logging) |
Logging Start Options | Push button start (With configurable start delay from 1 minute to 72 hours) or specific date and time |
Alarms | Up to 6 individually configurable alarms for each channel Possible to set alarms separately for Channel 1 and Channel 2 |
Download Time | Typically with full memory (32,000 readings) in less than 20 seconds |
Environmental | IP61 (When vertically mounted or hung with USB dust-cap in place) |
Real Time Clock | Built-in real time clock Rated accuracy ±25 ppm at 77°F (25°C), equivalent to 2.5 seconds/day ↵Rated temperature coefficient is -0.034 ±0.006 ppm/°C (I.e typically ± 0.00294 seconds/day/°C) |
Standard Remote Probe Cable Lengths | Standard: 1.5 m (4’11") Extended: 3 m (9’10"), recommended maximum |
Remote Probe Cable Type | PTFE (FDA food contact rated) coaxial |
Connection Interface | USB 2.0/micro USB socket |
Case Material | Polycarbonate |
Power | Source: 5 V via micro USB socket or two 1.5 V AAA batteries. CR2032 LiMnO2 coin cell (backup logging function only) Life: AAA battery up to 12 months - if unit is operated without power supply |
Dimensions | 0.7 x 2.83 x 5.55" (18 x 72 x 141 mm) |
Weight | 0.34 lbs (158 g) with AAA batteries, 0.29 lbs (132 g) excluding probe and AAA batteries |
Click on a category to view a selection of compatible accessories with the LogTag UTREL30-16 Kit-2 Vaccine Kit with two external probes, -130 to 104°F, dual-channel.