Measure and store up to 16,000 temperature readings with this vaccine kit, capable of taking measurements from -40 to 210°F (-40 to 99°C) with an external probe. In addition, This kit comes with a USB temperature recorder, an external probe, a buffer bottle, a wall mount bracket, and a calibration certificate. This product includes a Traceable Calibration Certificate with full Data and Uncertainties.
Measure and store up to 16,000 temperature readings with this vaccine kit, capable of taking measurements from -40 to 210°F (-40 to 99°C) with an external probe. In addition, This kit comes with a USB temperature recorder, an external probe, a buffer bottle, a wall mount bracket, and a calibration certificate. This product includes a Traceable Calibration Certificate with full Data and Uncertainties.
View temperature and alarm status of up to 6 alarms with this vaccine kit, featuring a cost-effective multi-use format with two-year battery life. Additionally, when the logger is connected to a computer using the integrated USB plug, a detailed PDF report of the recorded temperature data and alarms can be automatically generated without extra accessories or software.
This product includes a Traceable Calibration Certificate with full Data and Uncertainties.
Features
Applications
Sensor Measurement Range | -40 to 210°F (-40 to 99°C) |
Temperature | Operating: -22 to 140°F (-30 to 60°C ) Storage: 32 to 104°F (-10 to 40°C) |
Rated Temperature Reading Resolution | 0.2°F (0.1°C) for -22 to 140°F (-30 to 60°C) 0.4°F (0.2°C) for -40 to -22°F (-40 to -30°C) 0.9°F (0.5°C) for 140 to 210°F (60 to 99°C) LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
Rated Temperature Reading Accuracy | Better than ±0.9°F (±0.5°C) for -4 to 104°F (-20 to 40°C), typically 0.6°F (±0.3°C) Better than ±1.4°F (±0.8°C) for -40 to -4°F (-40 to -20°C), typically ±0.9°F (0.5°C) Better than ±1.4°F (±0.8°C) for 104 to 158°F (40 to 70°C), typically 1.3°F (±0.7°C) Better than ±2.2°F (±1.2°C) for 158 to 210°F (70 to 99°C), typically ±1.8°F (1°C) |
Recording Capacity | 16,129 temperature readings 112 days at 10 minute logging, 168 days at 15 minute logging. Statistics memory (for display on LCD): Maximum/minimum values and alarm duration↵values. |
Sampling Interval | Configurable from 30 seconds to 18 hours |
Logging Start Options | Push button start or specific date and time |
Recording Indication | REC symbol on LCD |
Alarms | Three configurable upper and three configurable lower alarms |
Download Time | Typically with full memory (16,129 readings) in less than 30 seconds from time of insertion to availability of PDF report.↵Typically less than 10 seconds from time of insertion to availability of LTD file in LogTag® analyzer (if configured). |
Environmental | IP61 (when vertically mounted or hung with USB dust-cap in place) |
Real Time Clock | Built-in real time clock Rated accuracy ±25 ppm at 77°F (25°C) (equivalent to 2.5 seconds/day) Rated temperature coefficient is -0.034 ±0.006 ppm/°C (I.e typically ± 0.00294 seconds/day/°C) |
Standard External Probe Cable Lengths | Standard: 4’11" (1.5 m) Extended: 9’10" (3 m), recommended maximum |
Remote External Probe Type | PTFE (FDA food contact rated) coaxial |
Connection Interface | USB 2.0, A-type plug |
Software | PDF Reader, LogTag® analyzer 3.1.9 or higher |
PDF Report | One page report with trip and alarm summary. Multi-page report with list of readings, including date and time. |
Case Material | Polycarbonate |
Power | Source: 3 V CR2032 (LiMnO2), fixed battery Life: One year storage, two years of normal use (based on 15 minute logging, download data monthly). |
Dimensions | 0.33 x 2.14 x 3.66" (8.6 x 54.5 x 93 mm) |
Weight | 0.09 lbs (41 g) without external probe |
Click on a category to view a selection of compatible accessories with the LogTag UTRED-16-NIST USB Vaccine Kit with external probe, -40 to 210°F.
Sensor Measurement Range | -40 to 210°F (-40 to 99°C) |
Temperature | Operating: -22 to 140°F (-30 to 60°C ) Storage: 32 to 104°F (-10 to 40°C) |
Rated Temperature Reading Resolution | 0.2°F (0.1°C) for -22 to 140°F (-30 to 60°C) 0.4°F (0.2°C) for -40 to -22°F (-40 to -30°C) 0.9°F (0.5°C) for 140 to 210°F (60 to 99°C) LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
Rated Temperature Reading Accuracy | Better than ±0.9°F (±0.5°C) for -4 to 104°F (-20 to 40°C), typically 0.6°F (±0.3°C) Better than ±1.4°F (±0.8°C) for -40 to -4°F (-40 to -20°C), typically ±0.9°F (0.5°C) Better than ±1.4°F (±0.8°C) for 104 to 158°F (40 to 70°C), typically 1.3°F (±0.7°C) Better than ±2.2°F (±1.2°C) for 158 to 210°F (70 to 99°C), typically ±1.8°F (1°C) |
Recording Capacity | 16,129 temperature readings 112 days at 10 minute logging, 168 days at 15 minute logging. Statistics memory (for display on LCD): Maximum/minimum values and alarm duration↵values. |
Sampling Interval | Configurable from 30 seconds to 18 hours |
Logging Start Options | Push button start or specific date and time |
Recording Indication | REC symbol on LCD |
Alarms | Three configurable upper and three configurable lower alarms |
Download Time | Typically with full memory (16,129 readings) in less than 30 seconds from time of insertion to availability of PDF report.↵Typically less than 10 seconds from time of insertion to availability of LTD file in LogTag® analyzer (if configured). |
Environmental | IP61 (when vertically mounted or hung with USB dust-cap in place) |
Real Time Clock | Built-in real time clock Rated accuracy ±25 ppm at 77°F (25°C) (equivalent to 2.5 seconds/day) Rated temperature coefficient is -0.034 ±0.006 ppm/°C (I.e typically ± 0.00294 seconds/day/°C) |
Standard External Probe Cable Lengths | Standard: 4’11" (1.5 m) Extended: 9’10" (3 m), recommended maximum |
Remote External Probe Type | PTFE (FDA food contact rated) coaxial |
Connection Interface | USB 2.0, A-type plug |
Software | PDF Reader, LogTag® analyzer 3.1.9 or higher |
PDF Report | One page report with trip and alarm summary. Multi-page report with list of readings, including date and time. |
Case Material | Polycarbonate |
Power | Source: 3 V CR2032 (LiMnO2), fixed battery Life: One year storage, two years of normal use (based on 15 minute logging, download data monthly). |
Dimensions | 0.33 x 2.14 x 3.66" (8.6 x 54.5 x 93 mm) |
Weight | 0.09 lbs (41 g) without external probe |
Click on a category to view a selection of compatible accessories with the LogTag UTRED-16-NIST USB Vaccine Kit with external probe, -40 to 210°F.