WiFi-enabled data logger can remotely monitor an environment using an interchangeable J, K or T type thermocouple probe. Data is uploaded periodically using a standard WiFi network without the need to physically collect and connect the unit to a PC. Supplied with a K-type thermocouple probe.
WiFi-enabled data logger can remotely monitor an environment using an interchangeable J, K or T type thermocouple probe. Data is uploaded periodically using a standard WiFi network without the need to physically collect and connect the unit to a PC. Supplied with a K-type thermocouple probe.
The EL-WiFi-TC sensor measures the temperature of the environment in which the probe is situated. The accuracy of the K type probe supplied is ±1.5°C. Data is streamed wirelessly over any WiFi network and can be viewed on a PC using our free software package or on the EasyLog Cloud.
During configuration, the sensor will search for an existing wireless network while physically connected to the PC. It can then be placed anywhere within range of the network. If the sensor temporarily loses connectivity with the network, it will log readings until it is able to communicate again with the PC application or cloud service (max 30 days at 10 second sample interval). Logged data is retained if the battery goes flat. Although the EL-WiFi sensors have an impressive range this can be increased by using WiFi extenders.
The EL-WiFi-TC is suitable for a wide variety of applications, particularly where remote monitoring is important, these include:
Specification | Min. | Typ. | Max. | Unit |
---|---|---|---|---|
Battery life | 1* | Year | ||
USB supply voltage | 4.5 | 5 | 5.5 | Vd.c. |
Operating temperature range (sensor only) | -20 (-4) | +60 (+140) | °C (°F) | |
Logging period (user configurable) | 10 sec | 10 min | 12 hrs | |
Transmission period (user configurable) | 1 min | 1 hr | 24 hrs | |
Temperature measurement range (probe dependent) | -270 (-454) | +1300 (+2372) | °C (°F) | |
Temperature measurement resolution | 0.1 | °C | ||
Temperature display resolution (-99.9 to 999.9°C) | 0.1 | °C | ||
Temperature accuracy (probe dependent) | ±1.5 | °C |
Supplied Probe Specifications (K-type) | Min. | Typ. | Max. | Unit |
---|---|---|---|---|
Temperature accuracy | ±1.5 | °C | ||
Temperature range | 0 (+32) | +400 (+752) | °C (°F) | |
Probe length | 1500 | mm |
Specification | Min. | Typ. | Max. | Unit |
---|---|---|---|---|
Battery life | 1* | Year | ||
USB supply voltage | 4.5 | 5 | 5.5 | Vd.c. |
Operating temperature range (sensor only) | -20 (-4) | +60 (+140) | °C (°F) | |
Logging period (user configurable) | 10 sec | 10 min | 12 hrs | |
Transmission period (user configurable) | 1 min | 1 hr | 24 hrs | |
Temperature measurement range (probe dependent) | -270 (-454) | +1300 (+2372) | °C (°F) | |
Temperature measurement resolution | 0.1 | °C | ||
Temperature display resolution (-99.9 to 999.9°C) | 0.1 | °C | ||
Temperature accuracy (probe dependent) | ±1.5 | °C |
Supplied Probe Specifications (K-type) | Min. | Typ. | Max. | Unit |
---|---|---|---|---|
Temperature accuracy | ±1.5 | °C | ||
Temperature range | 0 (+32) | +400 (+752) | °C (°F) | |
Probe length | 1500 | mm |