Lascar EL-GFX-DTC EasyLog Dual Channel Thermocouple Data Logger with LCD

Model: EL-GFX-DTC | UPC: 7426042412466

Lascar EL-GFX-DTC EasyLog Dual Channel Thermocouple Data Logger with LCD

Model: EL-GFX-DTC | UPC: 7426042412466

Stand-alone data logger measures and stores more than 250,000 temperature readings per channel from two K, J or T-type thermocouple probes. Features user-programmable audible alarm thresholds with highly visible confidence/alarm LEDs and a graphic LCD that provides real-time analysis of data as a summary or as a graph. Includes two K-type thermocouple probes.

Stand-alone data logger measures and stores more than 250,000 temperature readings per channel from two K, J or T-type thermocouple probes. Features user-programmable audible alarm thresholds with highly visible confidence/alarm LEDs and a graphic LCD that provides real-time analysis of data as a summary or as a graph. Includes two K-type thermocouple probes.

Your Price $234.49 USD
Availability 3 to 4 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your EL-GFX-DTC EasyLog Dual Channel Thermocouple Data Logger with LCD

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your EL-GFX-DTC EasyLog Dual Channel Thermocouple Data Logger with LCD

Dual Channel Thermocouple Data Logger with Graphic Screen

The EL-GFX-DTC standalone USB data logger measures and stores over 250,000 temperature readings from two J, K, or T-type thermocouple inputs at a resolution of 0.1°C. Using the Windows control software (available as a free-download), users can quickly set up the data logger and view downloaded data by connecting the device to the PC's USB port using the supplied cable.

The data logger features a high-contrast graphic LCD and three-input buttons which allows users to start, stop and restart the data logger using on-screen menus. This menu also provides real-time analysis of data either as a data summary (showing highest & lowest readings and alarm conditions) or as a graph that updates as new data is added. Multiple data logging sessions can be stored on the device ready for upload to a PC at a later date.

The two replaceable ½AA batteries typically allow logging for up to four months.


Features:

  • Dual channel, compatible with K, J and T type Thermocouples
  • Logging rates between 1 second and 1 hour
  • Immediate, delayed, push-button or temperature triggered start mode
  • Graphic LCD shows real-time readings, graph and current status
  • Stores over 250,000 readings
  • Calibration certificate available

Applications:

The EL-GFX-DTC is suitable for a wide variety of applications, these include:

  • Pharmaceutical fridge monitoring
  • Transportation
  • Food & drink
  • Building & site monitoring
  • HVAC/R

Specifications:

Specification Min. Typ. Max. Unit
Probe measurement range K-type -200 (+328)   +1350 (+2462) °C (°F)
J-type -200 (+328)   +1190 (+2174) °C (°F)
T-type -200 (+328)   +390 (734) °C (°F)
Internal resolution   0.1 (0.1)*   °C (°F)
Accuracy (overall error)   ±0.5 (±0.9)**   °C (°F)
Logging rate Every 1 second   Every 1 hour Time
Operating temperature range* -10 (-14)   +40 (+104) °C (°F)
2 x ½AA 3.6V Lithium Battery Life   4†   Months

* Above 999.9°C/F display becomes 1°C. Internal resolution remains at 0.1°C/F.
** Quoted accuracy is for the data logger only when measuring within the specified operating temperature. Thermocouple error is not included and should also be taken into consideration.
*** Operating temperature applies to the data logger module only. Please consult the probe manufacturer for operating temperature of thermocouple.
† At 25°C and 10 minute logging rate with no alarm LEDs or sounder and minimal LCD use.

Click here for complete specifications on the Lascar EL-GFX-DTC

What's included with the Lascar EL-GFX-DTC

  • Lascar EL-GFX-DTC EasyLog Dual Channel Thermocouple Data Logger with LCD

Software:

Set up and data download of our EasyLog data loggers is enabled by our EL-WIN-USB software. It is compatible with 32-bit and 64-bit versions of Windows XP, Vista, 7 & 8.

Download the latest version of the software below. Please note, the software is not compatible with Mac or Linux.

Download Software

Dual Channel Thermocouple Data Logger with Graphic Screen

The EL-GFX-DTC standalone USB data logger measures and stores over 250,000 temperature readings from two J, K, or T-type thermocouple inputs at a resolution of 0.1°C. Using the Windows control software (available as a free-download), users can quickly set up the data logger and view downloaded data by connecting the device to the PC's USB port using the supplied cable.

The data logger features a high-contrast graphic LCD and three-input buttons which allows users to start, stop and restart the data logger using on-screen menus. This menu also provides real-time analysis of data either as a data summary (showing highest & lowest readings and alarm conditions) or as a graph that updates as new data is added. Multiple data logging sessions can be stored on the device ready for upload to a PC at a later date.

The two replaceable ½AA batteries typically allow logging for up to four months.


Features:

  • Dual channel, compatible with K, J and T type Thermocouples
  • Logging rates between 1 second and 1 hour
  • Immediate, delayed, push-button or temperature triggered start mode
  • Graphic LCD shows real-time readings, graph and current status
  • Stores over 250,000 readings
  • Calibration certificate available

Applications:

The EL-GFX-DTC is suitable for a wide variety of applications, these include:

  • Pharmaceutical fridge monitoring
  • Transportation
  • Food & drink
  • Building & site monitoring
  • HVAC/R

Specifications:

Specification Min. Typ. Max. Unit
Probe measurement range K-type -200 (+328)   +1350 (+2462) °C (°F)
J-type -200 (+328)   +1190 (+2174) °C (°F)
T-type -200 (+328)   +390 (734) °C (°F)
Internal resolution   0.1 (0.1)*   °C (°F)
Accuracy (overall error)   ±0.5 (±0.9)**   °C (°F)
Logging rate Every 1 second   Every 1 hour Time
Operating temperature range* -10 (-14)   +40 (+104) °C (°F)
2 x ½AA 3.6V Lithium Battery Life   4†   Months

* Above 999.9°C/F display becomes 1°C. Internal resolution remains at 0.1°C/F.
** Quoted accuracy is for the data logger only when measuring within the specified operating temperature. Thermocouple error is not included and should also be taken into consideration.
*** Operating temperature applies to the data logger module only. Please consult the probe manufacturer for operating temperature of thermocouple.
† At 25°C and 10 minute logging rate with no alarm LEDs or sounder and minimal LCD use.

Click here for complete specifications on the Lascar EL-GFX-DTC

What's included with the Lascar EL-GFX-DTC

  • Lascar EL-GFX-DTC EasyLog Dual Channel Thermocouple Data Logger with LCD

Software:

Set up and data download of our EasyLog data loggers is enabled by our EL-WIN-USB software. It is compatible with 32-bit and 64-bit versions of Windows XP, Vista, 7 & 8.

Download the latest version of the software below. Please note, the software is not compatible with Mac or Linux.

Download Software

More Lascar Products