Compliant with 21CFR Part 11, this ultra-low temperature cryogenic vaccine data logger is capable of monitoring vaccines in cryogenic dry ice storage and features a -148 to 212°F (-100 to 100°C) range with a probe. Additionally, this data logger records over 32,000 readings and is simple to set up using the 21CFR Part 11 software.

Compliant with 21CFR Part 11, this ultra-low temperature cryogenic vaccine data logger is capable of monitoring vaccines in cryogenic dry ice storage and features a -148 to 212°F (-100 to 100°C) range with a probe. Additionally, this data logger records over 32,000 readings and is simple to set up using the 21CFR Part 11 software.

Your Price $168.40 USD
Availability 2 to 3 Weeks
Quantity

Lascar EL-21CFR-ULT Offers

Comes with a software that allows users to set high and low alarm thresholds with alarm hold and delayed start features as well.

Features

  • T-type probe on 3.28084' (1 m) cable
  • Stores over 32,000 readings
  • Logging rates between 1 second and 12 hours
  • Immediate and delayed logging start
  • User-programmable alarm thresholds
  • Status indication via red and green LEDs
  • Use as part of a 21CFR Part 11 compliant system
  • EasyLog 21CFR software available as a free download

Applications

  • Ultra-low temperature vaccine storage
  • Vaccine storage
  • Pharmaceutical cold chain

Lascar EL-21CFR-ULT Specifications

Measurement Range -148 to 212°F (-100 to 100°C)
Internal Resolution 1°F (0.5°C)
Accuracy ±4.5°F (±2.5°C) typical
Readings 32,510
Logging Rate User selectable between 1 second and 12 hours
Operating Temperature (Logger Only) 14 to 104°F (-10 to 40°C)
Battery Life 2 Years (at 77°F or 25°C and 1 minute logging rate)
Dimensions Logger: 4.6 x 1.1 x 1.1" (118 x 27 x 27 mm)
Probe: 5.9 x θ0.05, 39.3" cable (150 x θ1.5 mm x 2 m cable)
Click here for complete specifications on the Lascar EL-21CFR-ULT

What's included with the Lascar EL-21CFR-ULT

  • Ultra Low Temperature Cryogenic Vaccine Data Logger
  • Thermocouple Probe
  • Mounting Bracket
  • Battery

Click on a category to view a selection of compatible accessories with the Lascar EL-21CFR-ULT Ultra Low Temperature Cryogenic Vaccine Data Logger, 21CFR-compliant, -148 to 212°F.

Lascar EL-P-TC-K-SPIKE K-Type Thermocouple Probe, 0.13" EL-P-TC-K-SPIKE
Ideal for use with temperature data loggers, this K-type thermocouple probe features a 0.13" (3.3 mm) diameter and is made from 316 stainless steel. In addition, this probe also features a Class 1 tolerance and is sealed to IP66 standard on a 3.28' (1 m) cable.




Lascar EL-P-TPX+ Calibratable Thermistor Probe for the EL-WiFi-TPX+ Data Loggers, 9.8' EL-P-TPX+
Intended for use with the EL-WiFi-TPX+ data loggers, this high accuracy and calibratable probe is 9.84' (3 m) long with a stainless steel tip.




Lascar FRIDGE INSTALL-TP Temperature Probe FRIDGE INSTALL-TP
For use with temperature data loggers, the temperature probe is ideal in measuring temperature.




Lascar THERMOCOUPLE-CS Thermocouple Probe THERMOCOUPLE-CS
Used as an accessory for temperature measurement.




Lascar EL-21CFR-ULT Offers

Comes with a software that allows users to set high and low alarm thresholds with alarm hold and delayed start features as well.

Features

  • T-type probe on 3.28084' (1 m) cable
  • Stores over 32,000 readings
  • Logging rates between 1 second and 12 hours
  • Immediate and delayed logging start
  • User-programmable alarm thresholds
  • Status indication via red and green LEDs
  • Use as part of a 21CFR Part 11 compliant system
  • EasyLog 21CFR software available as a free download

Applications

  • Ultra-low temperature vaccine storage
  • Vaccine storage
  • Pharmaceutical cold chain

Lascar EL-21CFR-ULT Specifications

Measurement Range -148 to 212°F (-100 to 100°C)
Internal Resolution 1°F (0.5°C)
Accuracy ±4.5°F (±2.5°C) typical
Readings 32,510
Logging Rate User selectable between 1 second and 12 hours
Operating Temperature (Logger Only) 14 to 104°F (-10 to 40°C)
Battery Life 2 Years (at 77°F or 25°C and 1 minute logging rate)
Dimensions Logger: 4.6 x 1.1 x 1.1" (118 x 27 x 27 mm)
Probe: 5.9 x θ0.05, 39.3" cable (150 x θ1.5 mm x 2 m cable)
Click here for complete specifications on the Lascar EL-21CFR-ULT

What's included with the Lascar EL-21CFR-ULT

  • Ultra Low Temperature Cryogenic Vaccine Data Logger
  • Thermocouple Probe
  • Mounting Bracket
  • Battery

Click on a category to view a selection of compatible accessories with the Lascar EL-21CFR-ULT Ultra Low Temperature Cryogenic Vaccine Data Logger, 21CFR-compliant, -148 to 212°F.

Lascar EL-P-TC-K-SPIKE K-Type Thermocouple Probe, 0.13" EL-P-TC-K-SPIKE
Ideal for use with temperature data loggers, this K-type thermocouple probe features a 0.13" (3.3 mm) diameter and is made from 316 stainless steel. In addition, this probe also features a Class 1 tolerance and is sealed to IP66 standard on a 3.28' (1 m) cable.




Lascar EL-P-TPX+ Calibratable Thermistor Probe for the EL-WiFi-TPX+ Data Loggers, 9.8' EL-P-TPX+
Intended for use with the EL-WiFi-TPX+ data loggers, this high accuracy and calibratable probe is 9.84' (3 m) long with a stainless steel tip.




Lascar FRIDGE INSTALL-TP Temperature Probe FRIDGE INSTALL-TP
For use with temperature data loggers, the temperature probe is ideal in measuring temperature.




Lascar THERMOCOUPLE-CS Thermocouple Probe THERMOCOUPLE-CS
Used as an accessory for temperature measurement.




More Lascar Products