Kyoritsu 6050 Combi Tester LOOP plus RCD

Model: 6050 | Order No: KEW6050

Kyoritsu 6050 Combi Tester LOOP plus RCD

Model: 6050 | Order No: KEW6050

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Single-Phase Power Quality Analyzers category for similar products.

Or let's do a search and help you find what you need:


Kyoritsu 6050 Offers

The Kyoritsu 6050 Combitester provides the ultimate in Microprocessor technology offering Loop and RCD tests with a comprehensive memory and downloading test results.

  • LOOP Impedance 200/2000Ω range measurement is carried out using a test current of 15mA. This current will not trip RCD’s rated at 30mA or greater.
  • High resolution for low Loop Impedance (resolution of 0.01Ω) on 20Ω range.
  • Direct reading of Prospective Short Circuit Current (PSC) and earth fault current.
  • RCD tests at 0 and 180 degree phase angle switch permit quick tests and consistent readings.
  • Test of a large kind of RCD's Standard, Selective, AC and A (DC sensitive breakers).
  • Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
  • RCD Ramp test in order to indicate the actual tripping current of RCD.
  • Contact Voltage Reading (UC). with two selectable contact voltage limits(50 and 25V).
  • Visual indication of correct wiring status and automatic lock-out if test resistors overheats.
  • Designed to IEC 61010-1, IEC 61557 and high protection degree IP54.
  • The stored data can be transferred to PC via Optical Adapter Model 8212-RS232C and 8212-USB.

Specifications:

Loop Impedance Ranges(Z reading) 20/200/2000Ω Loop Impedance Ranges without tripping RCDs 200 and 2000Ω with 15mA of test current Max test current on Loop ranges 3A (20Ω) / 15mA (200 and 2000Ω) PSC / Earth Fault Current Ranges 200/2000A/20kA RCD Test AC Type(Standard and Selective)

  • × 1/2 10, 30, 100, 300, 500, 1000mA
  • × 1 10, 30, 100, 300, 500, 1000mA
  • × 5 10, 30, 100mA
  • Auto Ramp 10, 30, 100, 300, 500mA

RCD Test A Type(Standard and Selective) 10, 30, 100, 300, 500mA RCD Test Currents multipliers

  • × 1/2, × 1, × 5
  • (max 1000mA type AC)
  • (max 500mA type A)

RCD Test Time Duration

  • 1000ms: × 1/2, × 1, DC
  • 200ms: × 5, DC (500mA), and × 1 (1000mA)

RCD Ramp Test From 20% to 110% of IΔn (AC type) Contact Voltage Block (RCD) 50V and 25V Contact Voltage Reading (RCD) 100.0V Phase and Earth(2 wires only) measurements

  • RCD (without DC)
  • LOOP

Working Voltage for Loop Tests

  • 20Ω: 230V+10%-15%
  • 200/2000Ω: 230V+10%-15% and 400V+10%-15%

Working Voltage for RCD Tests 230V+10%-15% Voltage Test

  • 100 ~ 260V
  • (LOOP 200/2000Ω, PSC 200A:100 ~ 440V)

Memory 300 memory locations PC Software, Connection Cable optional with 8212-USB, 8212-RS232C Safety Standards IEC 61010-1 CAT.III 300V, IEC 61557 Power Source 8 × 1.5V R6P(AA) Dimensions 186(L) × 167(W) × 89(D)mm Weight 980g

Accessories Included:

  • Molded Plug Test Lead 7125-EU
  • Pouch for Test Leads
  • Instruction Manual
  • Shoulder Strap
  • Batteries

Optional Accessories:

  • 7121B (Simplified measurement probe)
  • 8212-RS232C
  • (RS232C adaptor with KEW Report (Software))
  • 8212-USB
  • (USB adaptor with KEW Report (Software))

What's included with the Kyoritsu 6050

  • Kyoritsu 6050 Combi Tester LOOP plus RCD

Kyoritsu 6050 Offers

The Kyoritsu 6050 Combitester provides the ultimate in Microprocessor technology offering Loop and RCD tests with a comprehensive memory and downloading test results.

  • LOOP Impedance 200/2000Ω range measurement is carried out using a test current of 15mA. This current will not trip RCD’s rated at 30mA or greater.
  • High resolution for low Loop Impedance (resolution of 0.01Ω) on 20Ω range.
  • Direct reading of Prospective Short Circuit Current (PSC) and earth fault current.
  • RCD tests at 0 and 180 degree phase angle switch permit quick tests and consistent readings.
  • Test of a large kind of RCD's Standard, Selective, AC and A (DC sensitive breakers).
  • Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
  • RCD Ramp test in order to indicate the actual tripping current of RCD.
  • Contact Voltage Reading (UC). with two selectable contact voltage limits(50 and 25V).
  • Visual indication of correct wiring status and automatic lock-out if test resistors overheats.
  • Designed to IEC 61010-1, IEC 61557 and high protection degree IP54.
  • The stored data can be transferred to PC via Optical Adapter Model 8212-RS232C and 8212-USB.

Specifications:

Loop Impedance Ranges(Z reading) 20/200/2000Ω Loop Impedance Ranges without tripping RCDs 200 and 2000Ω with 15mA of test current Max test current on Loop ranges 3A (20Ω) / 15mA (200 and 2000Ω) PSC / Earth Fault Current Ranges 200/2000A/20kA RCD Test AC Type(Standard and Selective)

  • × 1/2 10, 30, 100, 300, 500, 1000mA
  • × 1 10, 30, 100, 300, 500, 1000mA
  • × 5 10, 30, 100mA
  • Auto Ramp 10, 30, 100, 300, 500mA

RCD Test A Type(Standard and Selective) 10, 30, 100, 300, 500mA RCD Test Currents multipliers

  • × 1/2, × 1, × 5
  • (max 1000mA type AC)
  • (max 500mA type A)

RCD Test Time Duration

  • 1000ms: × 1/2, × 1, DC
  • 200ms: × 5, DC (500mA), and × 1 (1000mA)

RCD Ramp Test From 20% to 110% of IΔn (AC type) Contact Voltage Block (RCD) 50V and 25V Contact Voltage Reading (RCD) 100.0V Phase and Earth(2 wires only) measurements

  • RCD (without DC)
  • LOOP

Working Voltage for Loop Tests

  • 20Ω: 230V+10%-15%
  • 200/2000Ω: 230V+10%-15% and 400V+10%-15%

Working Voltage for RCD Tests 230V+10%-15% Voltage Test

  • 100 ~ 260V
  • (LOOP 200/2000Ω, PSC 200A:100 ~ 440V)

Memory 300 memory locations PC Software, Connection Cable optional with 8212-USB, 8212-RS232C Safety Standards IEC 61010-1 CAT.III 300V, IEC 61557 Power Source 8 × 1.5V R6P(AA) Dimensions 186(L) × 167(W) × 89(D)mm Weight 980g

Accessories Included:

  • Molded Plug Test Lead 7125-EU
  • Pouch for Test Leads
  • Instruction Manual
  • Shoulder Strap
  • Batteries

Optional Accessories:

  • 7121B (Simplified measurement probe)
  • 8212-RS232C
  • (RS232C adaptor with KEW Report (Software))
  • 8212-USB
  • (USB adaptor with KEW Report (Software))

What's included with the Kyoritsu 6050

  • Kyoritsu 6050 Combi Tester LOOP plus RCD

More Kyoritsu Products