Kyoritsu 3126 High Voltage Insulation Tester

Model: 3126 | Order No: KEW3126

Kyoritsu 3126 High Voltage Insulation Tester

Model: 3126 | Order No: KEW3126

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

Kyoritsu 3127 High Voltage Insulation Tester, 250V to 5000V-

Kyoritsu 3127 High Voltage Insulation Tester, 250V to 5000V

Model: 3127 | Order No: KEW3127

Features 5mA short circuit current. Test Voltage range of 250V to 5000V. Advanced diagnosis function including Ramp Test (Breakdown and Burn modes) and tests for capacitance and leakage current.


Kyoritsu 3126 High Voltage Insulation Tester

The Kyoritsu 3126 High Voltage Insulation Tester Features a filter function that reduces noise interference for obtaining stable measurement.

  • Short-Circuit Current up to 5mA
  • Wide range measurements from 500V to 5000V and up to 1TΩ
  • Large digital display with Bar Graph indication and white LED back light
  • Polarization Index measurement (PI), Dielectric Absorption Ratio (DAR)
  • Indication of Output voltage and Discharge voltage
  • Auto-discharge function and Output voltage warning function
  • Auto power off and Battery Indicator
  • Safety standard IEC 61010-1 CAT.III 600V
Specification:

Measuring range 500V : 0.0~99.9MΩ/100~999MΩ 1000V : 0.0~99.9MΩ/100~999MΩ/1.00~1.99GΩ 2500V : 0.0~99.9MΩ/100~999MΩ/1.00~9.99GΩ/10.0~99.9GΩ 5000V : 0.0~99.9MΩ/100~999MΩ/1.00~9.99GΩ/10.0~99.9GΩ/100~1000GΩ/(1TΩ)

Accuracy 500V : ±5%rdg/±3dgt 1000V : ±5%rdg/±3dgt 2500V : ±5%rdg /±3dgt 5000V : ±5%rdg / ±3dgt /±20%(100GΩ or more)

Short Circuit Current : Max. 5mA

Rated test Current 500V : 1mA to 1.2mA at 0.5MΩ load 1000V : 1mA to 1.2mA at 1MΩ load 2500V : 1mA to 1.2mA at 2.5MΩ load 5000V : 1mA to 1.2mA at 5MΩ load

Open circuit voltage 500VDC : +30% , -0% 1000VDC : +20% , -0% 2500VDC : +20% , -0% 5000VDC : +20% , -0%

Maximum display: 999 Counts (1000 counts only at 1000GΩ)

Current consumption : 1000mA approx. (During measurement)

Withstand Voltage Safety standard 5320V AC for 5 seconds IEC 61010-1 CAT.III 600V, pollution Degree 2 /IEC 61010-031, IEC 61326

Power supply DC12V : LR14×8 pcs.

Dimensions 205(L) × 152(W) × 94(D)mm

Weight 1.8kg approx.

Accessories:

  • 7165A (Line probe), 7224A (Earth cord), 7225A (Guard cord)
  • 8019 (Hook type prod), 8254 (Extension prod), 9159 (Hard case)
  • LR14 (Alkaline battery size C) × 8,
  • Instruction manual, Calibration certificate
Optional:
  • 7168A (Line probe with alligator clip)
  • 7253 (Longer Line probe with alligator clip)
  • 8302 (Adaptor for recorder)

What's included with the Kyoritsu 3126

  • Kyoritsu 3126 High Voltage Insulation Tester

Kyoritsu 3126 High Voltage Insulation Tester

The Kyoritsu 3126 High Voltage Insulation Tester Features a filter function that reduces noise interference for obtaining stable measurement.

  • Short-Circuit Current up to 5mA
  • Wide range measurements from 500V to 5000V and up to 1TΩ
  • Large digital display with Bar Graph indication and white LED back light
  • Polarization Index measurement (PI), Dielectric Absorption Ratio (DAR)
  • Indication of Output voltage and Discharge voltage
  • Auto-discharge function and Output voltage warning function
  • Auto power off and Battery Indicator
  • Safety standard IEC 61010-1 CAT.III 600V
Specification:

Measuring range 500V : 0.0~99.9MΩ/100~999MΩ 1000V : 0.0~99.9MΩ/100~999MΩ/1.00~1.99GΩ 2500V : 0.0~99.9MΩ/100~999MΩ/1.00~9.99GΩ/10.0~99.9GΩ 5000V : 0.0~99.9MΩ/100~999MΩ/1.00~9.99GΩ/10.0~99.9GΩ/100~1000GΩ/(1TΩ)

Accuracy 500V : ±5%rdg/±3dgt 1000V : ±5%rdg/±3dgt 2500V : ±5%rdg /±3dgt 5000V : ±5%rdg / ±3dgt /±20%(100GΩ or more)

Short Circuit Current : Max. 5mA

Rated test Current 500V : 1mA to 1.2mA at 0.5MΩ load 1000V : 1mA to 1.2mA at 1MΩ load 2500V : 1mA to 1.2mA at 2.5MΩ load 5000V : 1mA to 1.2mA at 5MΩ load

Open circuit voltage 500VDC : +30% , -0% 1000VDC : +20% , -0% 2500VDC : +20% , -0% 5000VDC : +20% , -0%

Maximum display: 999 Counts (1000 counts only at 1000GΩ)

Current consumption : 1000mA approx. (During measurement)

Withstand Voltage Safety standard 5320V AC for 5 seconds IEC 61010-1 CAT.III 600V, pollution Degree 2 /IEC 61010-031, IEC 61326

Power supply DC12V : LR14×8 pcs.

Dimensions 205(L) × 152(W) × 94(D)mm

Weight 1.8kg approx.

Accessories:

  • 7165A (Line probe), 7224A (Earth cord), 7225A (Guard cord)
  • 8019 (Hook type prod), 8254 (Extension prod), 9159 (Hard case)