This product features an elegant and easy-to-use design and has an enhanced current measuring function that uses an external clamp sensor. It has two detachable holders: flat and wing type.
This product features an elegant and easy-to-use design and has an enhanced current measuring function that uses an external clamp sensor. It has two detachable holders: flat and wing type.
Features:
| AC/DC V | |
| Range | AC: 6.000/60.00/600.0V DC: 6.000/60.00/600.0V |
| Accuracy | AC: ±1.0%rdg±3dgt [40 - 500Hz] DC: ±0.5%rdg±3dgt |
AC/DC mV |
| Range | AC: 600.0mV DC: 600.0mV |
| Accuracy | AC: ±2.0%rdg±3dgt [40 - 500Hz] DC: ±1.5%rdg±3dgt |
AC/DC A |
| Range | AC: 6.000/10.00A DC: 6.000/10.00A |
| Accuracy | AC: ±1.5%rdg±3dgt [40 - 500Hz] DC: ±1.5%rdg±3dgt |
General Specifications |
| Continuity buzzer | 600Ω (Buzzer sounds below 90Ω) |
| Diode test | Open-loop voltage: <3.0V |
| Capacitance | 60.00/600.0nF/6.000/60.00/600.0/1000μF ±2.0%rdg±5dgt(60/600nF), ±5.0%rdg±5dgt(6/60/600/1000μF) |
| Dimensions | 155(L) x 75(W) x 35(D) mm |
| AC/DC V | |
| Range | AC: 6.000/60.00/600.0V DC: 6.000/60.00/600.0V |
| Accuracy | AC: ±1.0%rdg±3dgt [40 - 500Hz] DC: ±0.5%rdg±3dgt |
AC/DC mV |
| Range | AC: 600.0mV DC: 600.0mV |
| Accuracy | AC: ±2.0%rdg±3dgt [40 - 500Hz] DC: ±1.5%rdg±3dgt |
AC/DC A |
| Range | AC: 6.000/10.00A DC: 6.000/10.00A |
| Accuracy | AC: ±1.5%rdg±3dgt [40 - 500Hz] DC: ±1.5%rdg±3dgt |
General Specifications |
| Continuity buzzer | 600Ω (Buzzer sounds below 90Ω) |
| Diode test | Open-loop voltage: <3.0V |
| Capacitance | 60.00/600.0nF/6.000/60.00/600.0/1000μF ±2.0%rdg±5dgt(60/600nF), ±5.0%rdg±5dgt(6/60/600/1000μF) |
| Dimensions | 155(L) x 75(W) x 35(D) mm |