INOR R130 TC Digital 2-Wire Transmitter for thermocouple with wireless communication

Model: R130 TC | Order No: 70R1300211

INOR R130 TC Digital 2-Wire Transmitter for thermocouple with wireless communication

Model: R130 TC | Order No: 70R1300211

The APAQ R130 TC is a modern transmitter with high reliability and great performance. External influences such as ambient temperature, vibration, moisture and EMC interference have minimal influence on the measurement result, thanks to the robust design.

The APAQ R130 TC is a modern transmitter with high reliability and great performance. External influences such as ambient temperature, vibration, moisture and EMC interference have minimal influence on the measurement result, thanks to the robust design.

Your Price $102.00 USD
Availability 4 to 5 Weeks
Quantity

INOR R130 TC Specifications

Type Rail mounted
Input Thermocouple: B, E, J, K, N, R, S and T
Type of Transmitter Digital
Output 4-20 mA
Measuring Range Type J: -346 to 2192°F (-210 to 1200°C)
Type K, N: -454 to 2372°F (-270 to 1300°C)
Type R, S: -58 to 3182°F (-50 to 1750°C)
Type B, E, T: See data sheet
Sensor Error NAMUR NE43
Adjustments - Zero Point Any value within range limits
Adjustments - Minimum Span 36°F (20°C)
Ambient Temperature -40 to 185°F (-40 to 85°C)
Humidity 0 to 98% RH (non-condensing)
Vibration IEC 60068-2-6.5 g
EMC EN 61326-1 and EN 61326-2-3
Isolation Unisolated
Power Supply 6 to 32 VDC
Long-Term Stability Max. drift ±0.05% of span/year
Typical Accuracy Type E, J, K, N: ±1 K or ±0.2% of span
Type B, R, S, T: ±2 K or ±0.2% of span
Adjustable Filtering Level 0.4 to 26 s
Configuration App: INOR Connect*
Wireless Communication NFCTM

What's included with the INOR R130 TC

  • INOR R130 TC Digital 2-Wire Transmitter for thermocouple with wireless communication

INOR R130 TC Specifications

Type Rail mounted
Input Thermocouple: B, E, J, K, N, R, S and T
Type of Transmitter Digital
Output 4-20 mA
Measuring Range Type J: -346 to 2192°F (-210 to 1200°C)
Type K, N: -454 to 2372°F (-270 to 1300°C)
Type R, S: -58 to 3182°F (-50 to 1750°C)
Type B, E, T: See data sheet
Sensor Error NAMUR NE43
Adjustments - Zero Point Any value within range limits
Adjustments - Minimum Span 36°F (20°C)
Ambient Temperature -40 to 185°F (-40 to 85°C)
Humidity 0 to 98% RH (non-condensing)
Vibration IEC 60068-2-6.5 g
EMC EN 61326-1 and EN 61326-2-3
Isolation Unisolated
Power Supply 6 to 32 VDC
Long-Term Stability Max. drift ±0.05% of span/year
Typical Accuracy Type E, J, K, N: ±1 K or ±0.2% of span
Type B, R, S, T: ±2 K or ±0.2% of span
Adjustable Filtering Level 0.4 to 26 s
Configuration App: INOR Connect*
Wireless Communication NFCTM