It features a universal signal converter adapted for measurement with Pt100, thermocouple, voltage or potentiometer to minimize inventory and the number of installed product variants. The IPAQ C330 is available with ATEX, IECEx and cFMus certifications, making it a safe choice for a large number of applications.
It features a universal signal converter adapted for measurement with Pt100, thermocouple, voltage or potentiometer to minimize inventory and the number of installed product variants. The IPAQ C330 is available with ATEX, IECEx and cFMus certifications, making it a safe choice for a large number of applications.
The IPAQ C330 is a modern signal converter developed to meet high demands on flexibility, accuracy and reliability. It supports wireless communication via NFC® and Bluetooth® which makes it possible to configure and monitor the signal converter via a smartphone or tablet.
| Type | Head mounted |
| Entrance | RTD, TC, mV, ohm |
| Input RTD | Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10 |
| Input Thermocouple | Type B, C, D, E, J, K, N, R, S, T |
| Type of Signal Converter | Digital |
| Output | 4-20 mA |
| Galvanic Isolation | 1500 VAC |
| Number of Measurement Channels | 1 channel |
| Sensor Connection | 2, 3, 4-conductor coupling |
| Connection Voltage | IPAQ-C330: 8 to 36 VDC IPAQ-C330X: 8 to 30 VDC |
| Approval | ATEX, IECEx, cFMus |
| Typical Inaccuracy | 0.08% of the measuring range |
| Stability Over Time | Max. operation ±0.02% of the measurement range/year |
| Vibration | IEC 60068-2-6, 10g |
| Operating Time Meter | Counts the number of hours in operation |
| Simulated Output | Fixed output current for max. 15 min |
| Configuration | ConSoft or INOR Connect |
| Wireless Communication | NFC® and Bluetooth® * * Bluetooth® communication is only supported together with ICON-BT |
| Type | Head mounted |
| Entrance | RTD, TC, mV, ohm |
| Input RTD | Pt100, Pt1000, Ni100, Ni120, Ni1000, Cu10 |
| Input Thermocouple | Type B, C, D, E, J, K, N, R, S, T |
| Type of Signal Converter | Digital |
| Output | 4-20 mA |
| Galvanic Isolation | 1500 VAC |
| Number of Measurement Channels | 1 channel |
| Sensor Connection | 2, 3, 4-conductor coupling |
| Connection Voltage | IPAQ-C330: 8 to 36 VDC IPAQ-C330X: 8 to 30 VDC |
| Approval | ATEX, IECEx, cFMus |
| Typical Inaccuracy | 0.08% of the measuring range |
| Stability Over Time | Max. operation ±0.02% of the measurement range/year |
| Vibration | IEC 60068-2-6, 10g |
| Operating Time Meter | Counts the number of hours in operation |
| Simulated Output | Fixed output current for max. 15 min |
| Configuration | ConSoft or INOR Connect |
| Wireless Communication | NFC® and Bluetooth® * * Bluetooth® communication is only supported together with ICON-BT |