Hioki CT6872 AC/DC Current Sensor with 9.8-feet cable, 50 A

Model: CT6872

Hioki CT6872 AC/DC Current Sensor with 9.8-feet cable, 50 A

Model: CT6872

Low-current Model of 50 A rating, with Wideband and High AccuracyHioki's pass-through type AC/DC current sensors can be connected directly to Hioki Power Analyzers and Memory HiCorders. Also, it can be connected to Power Meters, Oscilloscopes, DMMs, etc. by using an optional sensor unit. The CT6872 has a frequency bandwidth of DC to 10 MHz and a rated current of 50 A. It is used for R&D, quality evaluation, manufacturing, and maintenance in markets such as wireless charging systems, inverter motors for industrial equipment, power conditioners for PV, and quick charging facilities for EVs.

Low-current Model of 50 A rating, with Wideband and High AccuracyHioki's pass-through type AC/DC current sensors can be connected directly to Hioki Power Analyzers and Memory HiCorders. Also, it can be connected to Power Meters, Oscilloscopes, DMMs, etc. by using an optional sensor unit. The CT6872 has a frequency bandwidth of DC to 10 MHz and a rated current of 50 A. It is used for R&D, quality evaluation, manufacturing, and maintenance in markets such as wireless charging systems, inverter motors for industrial equipment, power conditioners for PV, and quick charging facilities for EVs.

Your Price $1733.00 USD
Availability 2 to 3 Weeks
Quantity

Hioki CT6872 Offers

Hioki's pass-through type AC/DC current sensors can be connected directly to Hioki Power Analyzers and Memory HiCorders. Also, it can be connected to Power Meters, Oscilloscopes, DMMs, etc. by using an optional sensor unit.

The CT6872 has a frequency bandwidth of DC to 10 MHz and a rated current of 50 A. It is used for R&D, quality evaluation, manufacturing, and maintenance in markets such as wireless charging systems, inverter motors for industrial equipment, power conditioners for PV, and quick charging facilities for EVs.

Features

  • Combined accuracy with HIOKI power analyzer PW8001, PW6001 and PW3390 is specified. For details of combined accuracy, refer to the instruction manual.
  • Wide-bandwidth DC to 10 MHz excellent frequency characteristics
  • Applications in the fields of electric and hybrid electric vehicles
  • Wide operating temperature range -40 to 185°F (-40 to 85°C) fit for automobile applications
  • Ideal for evaluation of solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters
  • For observing waveforms to be used with the oscilloscopes or Memory HiCorders (use with Sensor Unit)
  • Accuracy guaranteed for one year

Flux gate detection

Flux gate detection delivers outstanding linear properties, and can measure currents of a wide range of magnitudes with high accuracy.

The fluxgate components used for DC detection have very low offset over a wide temperature range due to their operating principle, resulting in high accuracy and excellent temperature stability. It is ideal for measurements that require high accuracy, such as Power analyzers and Power meters. It can be used for measurement such as inverter efficiency, inverter output power, reactor/transformer loss, and long-term DC measurements.

Automatic Phase Correction function

To accurately measure high frequency and low power factor, it is important to correct phase errors. The PW8001 automatically acquires and corrects the phase of the current sensor with 0.001°resolution, bringing out the best performance of the current sensor without any effort.

Automatic current sensor detection by Power Analyzer PW8001

The current sensor is equipped with a memory (I2C-EEPROM).

When the current sensor is connected to the Power Analyzer PW8001, the phase correction data, rated current, sensor's model name, and serial number are automatically recognized by the instrument.

In the past, phase correction values had to be entered manually.

However, thanks to the automatic detection system of current sensor information, forgetting settings and typing errors are eliminated, allowing for more accurate power calculations.

Hioki CT6872 Specifications

Rated Current 50 A AC/DC
Frequency Bandwidth Amplitude: DC to 10 MHz
Phase: DC to 1 MHz
Output Voltage 40 mV/A rated (This device outputs AC+DC voltage via the Sensor Unit)
Basic Accuracy DC (±0.03% rdg. ±0.002% f.s., no phase specification)
45 Hz ≤ f ≤ 66 Hz (±0.03% rdg. ±0.007% f.s., ±0.05°)
Specified up to 1 MHz

What's included with the Hioki CT6872

  • AC/DC Current Sensor
  • 6 x Mark Bands
  • Instruction Manual
  • Operating Precautions

Hioki CT6872 Offers

Hioki's pass-through type AC/DC current sensors can be connected directly to Hioki Power Analyzers and Memory HiCorders. Also, it can be connected to Power Meters, Oscilloscopes, DMMs, etc. by using an optional sensor unit.

The CT6872 has a frequency bandwidth of DC to 10 MHz and a rated current of 50 A. It is used for R&D, quality evaluation, manufacturing, and maintenance in markets such as wireless charging systems, inverter motors for industrial equipment, power conditioners for PV, and quick charging facilities for EVs.

Features

  • Combined accuracy with HIOKI power analyzer PW8001, PW6001 and PW3390 is specified. For details of combined accuracy, refer to the instruction manual.
  • Wide-bandwidth DC to 10 MHz excellent frequency characteristics
  • Applications in the fields of electric and hybrid electric vehicles
  • Wide operating temperature range -40 to 185°F (-40 to 85°C) fit for automobile applications
  • Ideal for evaluation of solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters
  • For observing waveforms to be used with the oscilloscopes or Memory HiCorders (use with Sensor Unit)
  • Accuracy guaranteed for one year

Flux gate detection

Flux gate detection delivers outstanding linear properties, and can measure currents of a wide range of magnitudes with high accuracy.

The fluxgate components used for DC detection have very low offset over a wide temperature range due to their operating principle, resulting in high accuracy and excellent temperature stability. It is ideal for measurements that require high accuracy, such as Power analyzers and Power meters. It can be used for measurement such as inverter efficiency, inverter output power, reactor/transformer loss, and long-term DC measurements.

Automatic Phase Correction function

To accurately measure high frequency and low power factor, it is important to correct phase errors. The PW8001 automatically acquires and corrects the phase of the current sensor with 0.001°resolution, bringing out the best performance of the current sensor without any effort.

Automatic current sensor detection by Power Analyzer PW8001

The current sensor is equipped with a memory (I2C-EEPROM).

When the current sensor is connected to the Power Analyzer PW8001, the phase correction data, rated current, sensor's model name, and serial number are automatically recognized by the instrument.

In the past, phase correction values had to be entered manually.

However, thanks to the automatic detection system of current sensor information, forgetting settings and typing errors are eliminated, allowing for more accurate power calculations.

Hioki CT6872 Specifications

Rated Current 50 A AC/DC
Frequency Bandwidth Amplitude: DC to 10 MHz
Phase: DC to 1 MHz
Output Voltage 40 mV/A rated (This device outputs AC+DC voltage via the Sensor Unit)
Basic Accuracy DC (±0.03% rdg. ±0.002% f.s., no phase specification)
45 Hz ≤ f ≤ 66 Hz (±0.03% rdg. ±0.007% f.s., ±0.05°)
Specified up to 1 MHz