Slim Clamp Design, Measure AC/DC Current with High Accuracy. Ideal for Vehicle Power TestingThe AC/DC Current Probe CT6833 features a 50% smaller size while delivering precise and reliable performance across a wide temperature range. Perfect for automotive testing, it simplifies installation in tight spaces, enhances measurement accuracy, and improves testing efficiency. Experience innovation that saves time and increases accuracy! Half the Size, Maximum Precision The slim design ensures easy installation even in tight spaces.
Slim Clamp Design, Measure AC/DC Current with High Accuracy. Ideal for Vehicle Power TestingThe AC/DC Current Probe CT6833 features a 50% smaller size while delivering precise and reliable performance across a wide temperature range. Perfect for automotive testing, it simplifies installation in tight spaces, enhances measurement accuracy, and improves testing efficiency. Experience innovation that saves time and increases accuracy! Half the Size, Maximum Precision The slim design ensures easy installation even in tight spaces.
The AC/DC Current Probe CT6833 features a 50% smaller size while delivering precise and reliable performance across a wide temperature range. Perfect for automotive testing, it simplifies installation in tight spaces, enhances measurement accuracy, and improves testing efficiency. Experience innovation that saves time and increases accuracy!
Features
Half the Size, Maximum Precision
The slim design ensures easy installation even in tight spaces.
Complex tasks in the engine room become simple and efficient, dramatically reducing preparation time for fuel efficiency and performance testing. Not only does it reduce setup time, but it also minimizes the risk of sensor damage from forced clamping between narrow spaces.
Fully compliant with the WLTP and SAE J1634 standards, it provides precise AC/DC current measurements up to 200 A with an impressive DC accuracy of 0.07%.
Current probes for automotive certification testing
The CT6833 and CT6834 offer industry-leading DC accuracy of ±0.07% rdg., meeting stringent standards such as WLTP and SAE J1634.
The current sensor minimizes the impact of conductor position, ensuring stable and reliable data under various connection conditions.
Operating temperature range: -40 to 185°F
The CT6833 can measure AC/DC currents rated up to 200 A rms.
With an operating temperature range from -40 to 185°F, it delivers exceptional temperature stability and low drift, enabling accurate measurements even in demanding temperature conditions for vehicle testing.
| Rated Current | 200 A AC/DC |
| Frequency Bandwidth | DC to 50 kHz |
| Diameter of Measurable Conductor | Maximum φ0.79" (20 mm) |
| Maximum Peak Current | Up to ±600 A peak are permitted at a temperature of ±104°F (40°C) or less and within 1 period of a periodic waveform of 10 ms or more (design value, out of guaranteed accuracy range) |
| Output Voltage | 10 mV/A |
| Measurement Accuracy | DC : ±0.07% rdg. ±0.01% f.s. 16 Hz ≤ f ≤ 66 Hz : ±0.07% rdg. ±0.007% f.s. Up to 20 kHz specified |
| Operating Temperature and Humidity Range | Sensor: -40 to 185°F (-40 to 85°C), 80% RH or less (non-condensing) Relay box: -13 to 122°F (-25 to 50°C), 80% RH or less (non-condensing) |
| Temperature Coefficient | The following numerical values are added to the measurement accuracy according to the temperature difference with the upper and lower limits of the guaranteed accuracy temperature range (64 or 82°F [18 or 28°C]) if operating temperatures are outside the guaranteed accuracy temperature range (73°F±9°F [23°C±5°C]). Sensor Amplitude accuracy: ±4 ppm of reading/°C (±0.8 ppm of reading/°C Typical) Offset voltage: ±3 ppm of full scale/°C (±0.5 ppm of full scale/°C Typical) Relay box Amplitude accuracy: ±15 ppm of reading/°C (±5 ppm of reading/°C Typical) Offset voltage: ±1 ppm of full scale/°C (±0.3 ppm of full scale/°C Typical) |
| Effects of Conductor Position | (For a conductor with an outer diameter of 10 mm) DC: ±0.03% of reading or less (±0.01% of reading Typical) 50 Hz/60 Hz: ±0.04% of reading or less (±0.015% of reading Typical) 1 kHz: ±0.1% of reading or less (±0.04% of reading Typical) 10 kHz: ±1% of reading or less (±0.3% of reading Typical) |
| Power Supply | Use Hioki instruments with an ME15W connector |
| Dimensions | Output cable length: Approximately 32.8' (10 m), including relay box Sensor: Approximately 5.9 x 1.8 x 0.6" (149 x 46 x 16.5 mm) Relay box: Approximately 5.0 x 2.2 x 0.8" (126 x 57 x 20.5 mm), excluding protrusions and cable |
| Weight | 25 oz. (710 g), approximately |
| Rated Current | 200 A AC/DC |
| Frequency Bandwidth | DC to 50 kHz |
| Diameter of Measurable Conductor | Maximum φ0.79" (20 mm) |
| Maximum Peak Current | Up to ±600 A peak are permitted at a temperature of ±104°F (40°C) or less and within 1 period of a periodic waveform of 10 ms or more (design value, out of guaranteed accuracy range) |
| Output Voltage | 10 mV/A |
| Measurement Accuracy | DC : ±0.07% rdg. ±0.01% f.s. 16 Hz ≤ f ≤ 66 Hz : ±0.07% rdg. ±0.007% f.s. Up to 20 kHz specified |
| Operating Temperature and Humidity Range | Sensor: -40 to 185°F (-40 to 85°C), 80% RH or less (non-condensing) Relay box: -13 to 122°F (-25 to 50°C), 80% RH or less (non-condensing) |
| Temperature Coefficient | The following numerical values are added to the measurement accuracy according to the temperature difference with the upper and lower limits of the guaranteed accuracy temperature range (64 or 82°F [18 or 28°C]) if operating temperatures are outside the guaranteed accuracy temperature range (73°F±9°F [23°C±5°C]). Sensor Amplitude accuracy: ±4 ppm of reading/°C (±0.8 ppm of reading/°C Typical) Offset voltage: ±3 ppm of full scale/°C (±0.5 ppm of full scale/°C Typical) Relay box Amplitude accuracy: ±15 ppm of reading/°C (±5 ppm of reading/°C Typical) Offset voltage: ±1 ppm of full scale/°C (±0.3 ppm of full scale/°C Typical) |
| Effects of Conductor Position | (For a conductor with an outer diameter of 10 mm) DC: ±0.03% of reading or less (±0.01% of reading Typical) 50 Hz/60 Hz: ±0.04% of reading or less (±0.015% of reading Typical) 1 kHz: ±0.1% of reading or less (±0.04% of reading Typical) 10 kHz: ±1% of reading or less (±0.3% of reading Typical) |
| Power Supply | Use Hioki instruments with an ME15W connector |
| Dimensions | Output cable length: Approximately 32.8' (10 m), including relay box Sensor: Approximately 5.9 x 1.8 x 0.6" (149 x 46 x 16.5 mm) Relay box: Approximately 5.0 x 2.2 x 0.8" (126 x 57 x 20.5 mm), excluding protrusions and cable |
| Weight | 25 oz. (710 g), approximately |