Eliminate the need for metallic contact with a live conductor with this electrical tester that allows quick and safe current measurements by simply sliding its open fork over a conductor. In addition, this kit comes equipped with a breaker finder.
Eliminate the need for metallic contact with a live conductor with this electrical tester that allows quick and safe current measurements by simply sliding its open fork over a conductor. In addition, this kit comes equipped with a breaker finder.
The FLK-BK120-T5-600 is a bundle that includes both the Fluke T5-600 Electrical Tester and BK120 SmartTrace™ Breaker Finder. The BK120 is a tool for identifying circuit breakers in electrical panels and detecting voltage with the NCV mode.
Features
BK120:
T5-600 Electrical Tester:
Applications
Transmitter | |
Safety Rating | CAT III 150 V |
Rated Operating Voltage | 110 V AC to 125 V AC at 6 mA |
Rated Frequency | 50/60 Hz |
GFCI Test | Yes |
Wiring Check | Yes |
Wiring Indication | 1 red, 2 green |
Power Supply | Line powered |
Receiver | |
Safety Rating | CAT III 150 V |
Breaker Finder Indication | Visual and audio |
NCV Detection | 90 V AC to 240 V AC, 50/60 Hz Dual sensitivity Visual and audio indications |
Flashlight | Yes |
Auto Power Off | Yes |
Low Battery Indication | Yes |
Power Supply | 2 AAA |
Electrical Tester | |
Jaw Opening | 0.5" (12.9 mm) |
Max Wire Size | 1/0 THHN Cable |
Current Range AC rms | 0 to 100 A |
Accuracy AC Current (50/60 Hz) | 3% ± 3 counts |
AC Response | Averaging |
Voltage | Range AC/DC: 0 to 600 V Accuracy: AC: 1.5% ± 2 counts DC: 1% ± 1 count |
Resistance Range | 0 to 1000 Ω |
Continuity Beeper Threshold | On at < 25 Ω, off at > 400 Ω |
Volts Indicator LED Threshold | Guaranteed on by 30 V AC |
Safety Rating | IEC 61010-2-032, IEC61010-2-033: CAT III 600 V, 100 A ac |
BK120
T5-600 Electrical Tester
Transmitter | |
Safety Rating | CAT III 150 V |
Rated Operating Voltage | 110 V AC to 125 V AC at 6 mA |
Rated Frequency | 50/60 Hz |
GFCI Test | Yes |
Wiring Check | Yes |
Wiring Indication | 1 red, 2 green |
Power Supply | Line powered |
Receiver | |
Safety Rating | CAT III 150 V |
Breaker Finder Indication | Visual and audio |
NCV Detection | 90 V AC to 240 V AC, 50/60 Hz Dual sensitivity Visual and audio indications |
Flashlight | Yes |
Auto Power Off | Yes |
Low Battery Indication | Yes |
Power Supply | 2 AAA |
Electrical Tester | |
Jaw Opening | 0.5" (12.9 mm) |
Max Wire Size | 1/0 THHN Cable |
Current Range AC rms | 0 to 100 A |
Accuracy AC Current (50/60 Hz) | 3% ± 3 counts |
AC Response | Averaging |
Voltage | Range AC/DC: 0 to 600 V Accuracy: AC: 1.5% ± 2 counts DC: 1% ± 1 count |
Resistance Range | 0 to 1000 Ω |
Continuity Beeper Threshold | On at < 25 Ω, off at > 400 Ω |
Volts Indicator LED Threshold | Guaranteed on by 30 V AC |
Safety Rating | IEC 61010-2-032, IEC61010-2-033: CAT III 600 V, 100 A ac |
BK120