Fluke Networks OFP2-100-S OptiFiber Pro Singlemode OTDR kit

Model: OFP2-100-S | UPC: 754082144540

Fluke Networks OFP2-100-S OptiFiber Pro Singlemode OTDR kit

Model: OFP2-100-S | UPC: 754082144540

Single Mode Module OTDR Kit.

Single Mode Module OTDR Kit.

Your Price $12688.00 USD
Availability 3 to 4 Weeks
Quantity
Add Gold Support to your OFP-100-S/INTL

Choose any one of these options

Clear selected options

Add Gold Support to your OFP-100-S/INTL

Choose any one of these options

Clear selected options


Fluke Networks OFP2-100-S Specifications

OTDR Specifications
  Multimode moduleSinglemode moduleQuad module
Wavelengths 850 nm ± 10 nm
1300 nm +35/-15 nm
1310 nm ± 25 nm
1550 nm ± 30 nm
850 nm ± 10 nm
1300 nm +35/-15 nm
1310 nm ± 25 nm
1550 nm ± 30 nm
Compatible Fiber Types 50/125 µm
62.5/125 µm
Singlemode50/125 µm
62.5/125 µm
Singlemode
Event Dead Zone 1 850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
Attenuation Dead Zone 2 850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
Dynamic Range 3, 5, 6 850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
Max Distance Range Setting 40 km130 kmMM: 40 km
SM: 130 km
Distance Measurement Range 4, 5, 7, 8, 9, 10 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance Range 4, 5 850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical)
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65dB (typical)
1550 nm: -14 dB to -65 dB (typical)
Sample Resolution 3 cm to 400 cm3 cm to 400 cm3 cm to 400 cm
Pulse Widths (nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
Test Rime (per wavelength) Auto setting: 5 sec (typical)Auto setting: 10 sec (typical)Auto setting:
MM – 5 sec (typical)
SM – 10 sec (typical)
Quick test setting:
2 sec (typical)
Quick test setting:
5 sec (typical)
Quick test setting:
MM – 2 sec (typical)
SM – 5 sec (typical)
Best resolution setting:
2 to 180 sec
Best resolution setting:
5 to 180 sec
Best resolution setting:
MM – 2 to 180 sec M
SM – 5 to 180 sec
FaultMap setting:
2 sec (typical), 180 sec (max)
FaultMap setting:
10 sec (typical), 180 sec (max)
FaultMap setting:
MM - 2 sec (typical), MM - 180 sec (max)
SM - 10 sec (typical), SM - 180 sec (max)
DataCenter OTDR setting:
1 sec (typical at 850 nm), 7 sec (max)
DataCenter OTDR setting:
20 sec (typical), 40 sec (max)
DataCenter OTDR setting:
MM – 1 sec (typical at 850 nm) MM – 7 sec (max)
SM – 20 sec (typical) SM – 40 sec (max)
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
-3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
FiberInspector Probe Specifications
Magnification~ 200X with OptiFiber Pro Display
Light sourceBlue LED
Power sourceTFS mainframe
Field of View (FOV)Horizontal: 425 µm
Vertical: 320 µm
Minimum detectable particle size0.5 µm
DimensionsApproximately 6.75 x 1.5 in (1175 x 35 mm) without adapter tip
Weight200 g
Temperature rangeOperating: 32 to 122°F (0 to 50 °C)
Storage: -4 to 158°F (-20 to 70°C)
CertificationsCE (when used with the mainframe)
VFL Specifications
On/Off controlMechanical switch and a button on the touch screen
Output power316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating wavelength650 nm nominal
Spectral width (RMS)±3 nm
Output modesContinuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector adapter2.5 mm universal
Laser safety (classification)Class II CDRH Complies to EN 60825-2
General Specifications
Weight3lbs, 5 oz (1.28 kg)
Dimensions2.625 x 5.25 x 11.0 in (6.67 x 13.33 x 27.94 cm)
BatteryLithium ion battery pack, 7.2 volts
Battery lifeEight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Charge TimeTester Off: Four hours to charge from 10% to 90% capacity
Tester On: Six hours to charge from 10% to 90% capacity with the tester on
Environmental Specifications
Operating temperature*-18 to 45°C
Non-operating temperature-30 to 60°C
Operating altitude4,000 m (13123 ft)
3200 m (10,500 ft) with AC adapter
Storage altitude12,000 m
EMCEN 61326-1
* Using battery power. With AC power: 0°C to 45°C. Real Time Trace function used for no more than 5 minutes in a 15-minute period. Maximum ambient temperature is 35°C for continuous use of the Real Time Trace function.
* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.
Click here for complete specifications on the Fluke Networks OFP2-100-S

What's Included:

  • OptiFiber Pro with SM OTDR Module
  • Carrying Strap
  • AC Adapter/Charger
  • USB Interface Cable - Standard A to Micro B
  • User Guide CD
  • LinkWare Software CD
  • Getting Started Guide
  • Registration Card
  • Factory-Based Warranty
  • Carrying Case

Fluke Networks OFP2-100-S Specifications

OTDR Specifications
  Multimode moduleSinglemode moduleQuad module
Wavelengths 850 nm ± 10 nm
1300 nm +35/-15 nm
1310 nm ± 25 nm
1550 nm ± 30 nm
850 nm ± 10 nm
1300 nm +35/-15 nm
1310 nm ± 25 nm
1550 nm ± 30 nm
Compatible Fiber Types 50/125 µm
62.5/125 µm
Singlemode50/125 µm
62.5/125 µm
Singlemode
Event Dead Zone 1 850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
Attenuation Dead Zone 2 850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
850 nm: 2.5 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
Dynamic Range 3, 5, 6 850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
850 nm: 28 dB typical
1300 nm: 30 dB typical
1310 nm: 32 dB typical
1550 nm: 30 dB typical
Max Distance Range Setting 40 km130 kmMM: 40 km
SM: 130 km
Distance Measurement Range 4, 5, 7, 8, 9, 10 850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance Range 4, 5 850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical)
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65dB (typical)
1550 nm: -14 dB to -65 dB (typical)
Sample Resolution 3 cm to 400 cm3 cm to 400 cm3 cm to 400 cm
Pulse Widths (nominal) 850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
Test Rime (per wavelength) Auto setting: 5 sec (typical)Auto setting: 10 sec (typical)Auto setting:
MM – 5 sec (typical)
SM – 10 sec (typical)
Quick test setting:
2 sec (typical)
Quick test setting:
5 sec (typical)
Quick test setting:
MM – 2 sec (typical)
SM – 5 sec (typical)
Best resolution setting:
2 to 180 sec
Best resolution setting:
5 to 180 sec
Best resolution setting:
MM – 2 to 180 sec M
SM – 5 to 180 sec
FaultMap setting:
2 sec (typical), 180 sec (max)
FaultMap setting:
10 sec (typical), 180 sec (max)
FaultMap setting:
MM - 2 sec (typical), MM - 180 sec (max)
SM - 10 sec (typical), SM - 180 sec (max)
DataCenter OTDR setting:
1 sec (typical at 850 nm), 7 sec (max)
DataCenter OTDR setting:
20 sec (typical), 40 sec (max)
DataCenter OTDR setting:
MM – 1 sec (typical at 850 nm) MM – 7 sec (max)
SM – 20 sec (typical) SM – 40 sec (max)
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
3, 5, 10, 20, 40, 60, 90, 120, 180 sec
Manual setting:
-3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
FiberInspector Probe Specifications
Magnification~ 200X with OptiFiber Pro Display
Light sourceBlue LED
Power sourceTFS mainframe
Field of View (FOV)Horizontal: 425 µm
Vertical: 320 µm
Minimum detectable particle size0.5 µm
DimensionsApproximately 6.75 x 1.5 in (1175 x 35 mm) without adapter tip
Weight200 g
Temperature rangeOperating: 32 to 122°F (0 to 50 °C)
Storage: -4 to 158°F (-20 to 70°C)
CertificationsCE (when used with the mainframe)
VFL Specifications
On/Off controlMechanical switch and a button on the touch screen
Output power316 µW (-5 dBm) = peak power = 1.0 mW (0 dBm)
Operating wavelength650 nm nominal
Spectral width (RMS)±3 nm
Output modesContinuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector adapter2.5 mm universal
Laser safety (classification)Class II CDRH Complies to EN 60825-2
General Specifications
Weight3lbs, 5 oz (1.28 kg)
Dimensions2.625 x 5.25 x 11.0 in (6.67 x 13.33 x 27.94 cm)
BatteryLithium ion battery pack, 7.2 volts
Battery lifeEight hour Auto OTDR operation, dual wavelength, no video probe connected, 150 m of fiber
Charge TimeTester Off: Four hours to charge from 10% to 90% capacity
Tester On: Six hours to charge from 10% to 90% capacity with the tester on
Environmental Specifications
Operating temperature*-18 to 45°C
Non-operating temperature-30 to 60°C
Operating altitude4,000 m (13123 ft)
3200 m (10,500 ft) with AC adapter
Storage altitude12,000 m
EMCEN 61326-1
* Using battery power. With AC power: 0°C to 45°C. Real Time Trace function used for no more than 5 minutes in a 15-minute period. Maximum ambient temperature is 35°C for continuous use of the Real Time Trace function.
* Do not keep battery at temperatures below -20°C (-4°F) or above 50°C (122°F) for periods longer than one week to maintain battery capacity.
Click here for complete specifications on the Fluke Networks OFP2-100-S

What's Included:

  • OptiFiber Pro with SM OTDR Module
  • Carrying Strap
  • AC Adapter/Charger
  • USB Interface Cable - Standard A to Micro B
  • User Guide CD
  • LinkWare Software CD
  • Getting Started Guide
  • Registration Card
  • Factory-Based Warranty
  • Carrying Case

More Fluke Networks Products