Accelerate every step of the copper certification process with this Versiv Professional Kit, which comes with the integrated Wi-Fi function pre-disabled. This kit comes with the DSX2-8000 wired CableAnalyzer, CertiFiber Pro, OptiFiber Pro, Fiber Inspection, and a full complement of product accessories.
Accelerate every step of the copper certification process with this Versiv Professional Kit, which comes with the integrated Wi-Fi function pre-disabled. This kit comes with the DSX2-8000 wired CableAnalyzer, CertiFiber Pro, OptiFiber Pro, Fiber Inspection, and a full complement of product accessories.
The DSX CableAnalyzer Series copper cable certifiers enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down – setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand.
As part of the Versiv cabling certification product family, the DSX CableAnalyzer Series copper cable certifiers provides accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements. The difference between being profitable or not is just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy, making jobs easier to manage, and getting to system acceptance faster. It’s not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.
Features
| Copper Certifications | |
| Category 6A / Class EA Test Time | 8 Seconds |
| Category 8 / Class I/II Test Time | 16 Seconds |
| HDTDX/HDTDR Diagnostic Test Times | ~3 Seconds |
| Internal Memory | ~5,000 Cat 8 with plots ~12,000 Cat 6A with plots |
| Level V Accuracy | 1 GHz |
| Level VI Accuracy | 2 GHz |
| Resistance Unbalance Measurement | Yes |
| Shield Integrity Check | Yes |
| TCL Measurement | Yes |
| ELTCTL Measurement | Yes |
| CDNEXT Measurement | Yes |
| CMRL Measurement | Yes |
| Built in Alien XTalk Module | Yes |
| Channel Adapter | 2 GHz Range |
| Permanent Link Adapter | 2 GHz Range |
| Environmental | |
| Operating Temperature | 32°F to 113°F (0°C to 45°C) |
| Storage Temperature | -22°F to 140°F (-30°C to 60°C) |
| Operating Relative Humidity (% RH Without Condensation) | 0% to 90%, 32°F to 95°F (0°C to 35°C) 0% to 70%, 95°F to 113°F (35°C to 45°C) |
| Vibration | Random, 2 g, 5 Hz-500 Hz |
| Shock | 1 m drop test with and without module and adapter |
| Safety | CSA 22.2 No. 61010, IEC 61010-1 3rd Edition |
| Operating Altitude | 13,123" (4,000 m) 10,500" (3,200 m) with AC Adapter |
| EMC | EN 61326-1 |
| General Specifications | |
| Autotest Time | Full 2-way Autotest of Cat 5e or 6/Class D or E: 7 seconds Full 2-way Autotest of Cat 6A/Class EA: 8 seconds Full 2-way Autotest of Cat 8: 16 seconds |
| Support Test Parameters | Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F) |
| Input Protection | Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
| Display | 5.7 in LCD display with a projected capacitance touchscreen |
| Case | High impact plastic with show absorbing overmold |
| Dimensions | Main Versiv unit with DSX module and battery installed: 2.625 x 5.25 x 11.0" (6.67 x 13.33 x 27.94 cm) |
| Weight | Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg) |
| Main Unit and Remote | Lithium ion battery pack, 7.2 V |
| Typical Battery Life | 8 hours |
| Charge time | Tester off: 4 hours to charge from 10 % capacity to 90 % capacity |
| Languages Supported | English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Traditional Chinese, Czech, Polish, Swedish, Hungarian |
| Calibration | Service center calibration period is 1 year |
Versiv mainframe and Accessories:
(2) Versiv Mainframes, (2) Headsets, (2) Hand Straps, (2) Shoulder Straps, Hard sided Carry Case, (2) Large Duffle Bags, (1) Backpack straps for Versiv Duffle Bag, (2) Versiv stands, USB Interface Cable, (2) AC Chargers, (2) Universal Couplers, Statement of Calibration, and Getting Started Guide
DSX CableAnalyzer:
(2) DSX-8000 CableAnalyzer Modules, (2) AxTalk Terminators, Set of Cat 8/Class I Permanent Link Adaptors, Set of Cat 8/Class I Channel Adaptors, DSX Series Coaxial Adapter Set, DSX Patch Cord Test Adapter Set for Category 5e patch cords, DSX Patch Cord Test Adapter Set for Category 6 patch cords, DSX Patch Cord Test Adapter Set for Category 6A patch cords, DSX M12 4-position Channel Adapter Set
CertiFiber Pro Quad OLTS:
(2) CertiFiber Pro Quad OLTS Modules, (4) Sets of 50 µm Multimode EF TRC kits: SC/LC (2 SC/LC, 2 LC/LC), SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC), 4 Sets of 62.5 µm Multimode EF TRC kits: SC/LC (2 SC/LC, 2 LC/LC), SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC), 6 Sets of 9 µm Singlemode TRC kits: SC/SCAPC (2 SC/SCAPC, 2 SCAPC/SCAPC), SC/LCAPC (2 SC/LCAPC, 2 LCAPC/LCAPC), SC/LC (2 SC/LC, 2 LC/LC), SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC), 4 TRC Carry Cases, 4 Sets of Interchange Adapters (LC – installed on units, SC, ST and FC)
OptiFiber Pro Quad OTDR:
OptiFiber Pro Quad OTDR Module, 50 µm Multimode Launch Cords (2 SC/LC, 3 SC/SC, 2 SC/ST, 2 SC/FC, 1 LC/LC, 1 ST/ST, 1 FC/FC), 62.5 µm Multimode Launch Cords (2 SC/LC, 2 SC/SC, 2 SC/ST, 2 SC/FC), 9 µm Singlemode Launch Cords (2 SC/LC, 3 SC/SC, 2 SC/ST, 2 SC/FC, 1 LC/LC, 1 ST/ST, 1 FC/FC, 2 SC/SCAPC, 2 SC/LCAPC), 50 µm Multimode TRC OTDR port saver (SC/SC, LC/LC), 62.5 µm Multimode TRC OTDR port saver (SC/SC, LC/LC), 9 µm Singlemode TRC OTDR port saver (SC/SC, LC/LC), OTDR Source Port Interchange Adapter Sets (LC – installed on unit, SC/ST, FC), (2) OTDR Hanging straps and magnets
Fiber Inspection and Cleaning:
(2) Versiv USB inspection cameras and tips sets, (2) Quick Clean Cleaners (1.25 mm), (2) Quick Clean Cleaners (2.50 mm), Enhanced Fiber Optic Cleaning Kit with Quick Clean cleaners
| Copper Certifications | |
| Category 6A / Class EA Test Time | 8 Seconds |
| Category 8 / Class I/II Test Time | 16 Seconds |
| HDTDX/HDTDR Diagnostic Test Times | ~3 Seconds |
| Internal Memory | ~5,000 Cat 8 with plots ~12,000 Cat 6A with plots |
| Level V Accuracy | 1 GHz |
| Level VI Accuracy | 2 GHz |
| Resistance Unbalance Measurement | Yes |
| Shield Integrity Check | Yes |
| TCL Measurement | Yes |
| ELTCTL Measurement | Yes |
| CDNEXT Measurement | Yes |
| CMRL Measurement | Yes |
| Built in Alien XTalk Module | Yes |
| Channel Adapter | 2 GHz Range |
| Permanent Link Adapter | 2 GHz Range |
| Environmental | |
| Operating Temperature | 32°F to 113°F (0°C to 45°C) |
| Storage Temperature | -22°F to 140°F (-30°C to 60°C) |
| Operating Relative Humidity (% RH Without Condensation) | 0% to 90%, 32°F to 95°F (0°C to 35°C) 0% to 70%, 95°F to 113°F (35°C to 45°C) |
| Vibration | Random, 2 g, 5 Hz-500 Hz |
| Shock | 1 m drop test with and without module and adapter |
| Safety | CSA 22.2 No. 61010, IEC 61010-1 3rd Edition |
| Operating Altitude | 13,123" (4,000 m) 10,500" (3,200 m) with AC Adapter |
| EMC | EN 61326-1 |
| General Specifications | |
| Autotest Time | Full 2-way Autotest of Cat 5e or 6/Class D or E: 7 seconds Full 2-way Autotest of Cat 6A/Class EA: 8 seconds Full 2-way Autotest of Cat 8: 16 seconds |
| Support Test Parameters | Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F) |
| Input Protection | Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
| Display | 5.7 in LCD display with a projected capacitance touchscreen |
| Case | High impact plastic with show absorbing overmold |
| Dimensions | Main Versiv unit with DSX module and battery installed: 2.625 x 5.25 x 11.0" (6.67 x 13.33 x 27.94 cm) |
| Weight | Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg) |
| Main Unit and Remote | Lithium ion battery pack, 7.2 V |
| Typical Battery Life | 8 hours |
| Charge time | Tester off: 4 hours to charge from 10 % capacity to 90 % capacity |
| Languages Supported | English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Traditional Chinese, Czech, Polish, Swedish, Hungarian |
| Calibration | Service center calibration period is 1 year |
Versiv mainframe and Accessories:
(2) Versiv Mainframes, (2) Headsets, (2) Hand Straps, (2) Shoulder Straps, Hard sided Carry Case, (2) Large Duffle Bags, (1) Backpack straps for Versiv Duffle Bag, (2) Versiv stands, USB Interface Cable, (2) AC Chargers, (2) Universal Couplers, Statement of Calibration, and Getting Started Guide
DSX CableAnalyzer:
(2) DSX-8000 CableAnalyzer Modules, (2) AxTalk Terminators, Set of Cat 8/Class I Permanent Link Adaptors, Set of Cat 8/Class I Channel Adaptors, DSX Series Coaxial Adapter Set, DSX Patch Cord Test Adapter Set for Category 5e patch cords, DSX Patch Cord Test Adapter Set for Category 6 patch cords, DSX Patch Cord Test Adapter Set for Category 6A patch cords, DSX M12 4-position Channel Adapter Set
CertiFiber Pro Quad OLTS:
(2) CertiFiber Pro Quad OLTS Modules, (4) Sets of 50 µm Multimode EF TRC kits: SC/LC (2 SC/LC, 2 LC/LC), SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC), 4 Sets of 62.5 µm Multimode EF TRC kits: SC/LC (2 SC/LC, 2 LC/LC), SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC), 6 Sets of 9 µm Singlemode TRC kits: SC/SCAPC (2 SC/SCAPC, 2 SCAPC/SCAPC), SC/LCAPC (2 SC/LCAPC, 2 LCAPC/LCAPC), SC/LC (2 SC/LC, 2 LC/LC), SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC), 4 TRC Carry Cases, 4 Sets of Interchange Adapters (LC – installed on units, SC, ST and FC)
OptiFiber Pro Quad OTDR:
OptiFiber Pro Quad OTDR Module, 50 µm Multimode Launch Cords (2 SC/LC, 3 SC/SC, 2 SC/ST, 2 SC/FC, 1 LC/LC, 1 ST/ST, 1 FC/FC), 62.5 µm Multimode Launch Cords (2 SC/LC, 2 SC/SC, 2 SC/ST, 2 SC/FC), 9 µm Singlemode Launch Cords (2 SC/LC, 3 SC/SC, 2 SC/ST, 2 SC/FC, 1 LC/LC, 1 ST/ST, 1 FC/FC, 2 SC/SCAPC, 2 SC/LCAPC), 50 µm Multimode TRC OTDR port saver (SC/SC, LC/LC), 62.5 µm Multimode TRC OTDR port saver (SC/SC, LC/LC), 9 µm Singlemode TRC OTDR port saver (SC/SC, LC/LC), OTDR Source Port Interchange Adapter Sets (LC – installed on unit, SC/ST, FC), (2) OTDR Hanging straps and magnets
Fiber Inspection and Cleaning:
(2) Versiv USB inspection cameras and tips sets, (2) Quick Clean Cleaners (1.25 mm), (2) Quick Clean Cleaners (2.50 mm), Enhanced Fiber Optic Cleaning Kit with Quick Clean cleaners