Fluke Networks DSX2-8-PRO-NW Versiv Pro Kit with DSX, CFP, OFP, and INSCP, no Wi-Fi

Model: DSX2-8-PRO-NW | UPC: 754082147053

Fluke Networks DSX2-8-PRO-NW Versiv Pro Kit with DSX, CFP, OFP, and INSCP, no Wi-Fi

Model: DSX2-8-PRO-NW | UPC: 754082147053

Accelerate every step of the copper certification process with this Versiv Professional Kit, which comes with the integrated Wi-Fi function pre-disabled. This kit comes with the DSX2-8000 wired CableAnalyzer, CertiFiber Pro, OptiFiber Pro, Fiber Inspection, and a full complement of product accessories.

Accelerate every step of the copper certification process with this Versiv Professional Kit, which comes with the integrated Wi-Fi function pre-disabled. This kit comes with the DSX2-8000 wired CableAnalyzer, CertiFiber Pro, OptiFiber Pro, Fiber Inspection, and a full complement of product accessories.

Your Price $81402.00 USD
Availability 2 to 3 Weeks
Quantity

Fluke Networks DSX2-8-PRO-NW Offers

The DSX CableAnalyzer Series copper cable certifiers enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down – setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand.

As part of the Versiv cabling certification product family, the DSX CableAnalyzer Series copper cable certifiers provides accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements. The difference between being profitable or not is just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy, making jobs easier to manage, and getting to system acceptance faster. It’s not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.

Features

  • Versiv enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
  • LinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even location from any smart device
  • ProjX™ management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive™ user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  • LinkWare PC management software provides unmatched analysis of test results and professional test reports
  • The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple test that locates the problem

Fluke Networks DSX2-8-PRO-NW Specifications

Copper Certifications
Category 6A / Class EA Test Time 8 Seconds
Category 8 / Class I/II Test Time 16 Seconds
HDTDX/HDTDR Diagnostic Test Times ~3 Seconds
Internal Memory ~5,000 Cat 8 with plots
~12,000 Cat 6A with plots
Level V Accuracy 1 GHz
Level VI Accuracy 2 GHz
Resistance Unbalance Measurement Yes
Shield Integrity Check Yes
TCL Measurement Yes
ELTCTL Measurement Yes
CDNEXT Measurement Yes
CMRL Measurement Yes
Built in Alien XTalk Module Yes
Channel Adapter 2 GHz Range
Permanent Link Adapter 2 GHz Range
Environmental
Operating Temperature 32°F to 113°F (0°C to 45°C)
Storage Temperature -22°F to 140°F (-30°C to 60°C)
Operating Relative Humidity (% RH Without Condensation) 0% to 90%, 32°F to 95°F (0°C to 35°C)
0% to 70%, 95°F to 113°F (35°C to 45°C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Operating Altitude 13,123" (4,000 m)
10,500" (3,200 m) with AC Adapter
EMC EN 61326-1
General Specifications
Autotest Time Full 2-way Autotest of Cat 5e or 6/Class D or E: 7 seconds
Full 2-way Autotest of Cat 6A/Class EA: 8 seconds
Full 2-way Autotest of Cat 8: 16 seconds
Support Test Parameters Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End
Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input Protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with show absorbing overmold
Dimensions Main Versiv unit with DSX module and battery installed: 2.625 x 5.25 x 11.0" (6.67 x 13.33 x 27.94 cm)
Weight Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
Main Unit and Remote Lithium ion battery pack, 7.2 V
Typical Battery Life 8 hours
Charge time Tester off: 4 hours to charge from 10 % capacity to 90 % capacity
Languages Supported English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Traditional Chinese, Czech, Polish, Swedish, Hungarian
Calibration Service center calibration period is 1 year
Click here for complete specifications on the Fluke Networks DSX2-8-PRO-NW

What's included with the Fluke Networks DSX2-8-PRO-NW

Versiv mainframe and Accessories:

(2) Versiv Mainframes, (2) Headsets, (2) Hand Straps, (2) Shoulder Straps, Hard sided Carry Case, (2) Large Duffle Bags, (1) Backpack straps for Versiv Duffle Bag, (2) Versiv stands, USB Interface Cable, (2) AC Chargers, (2) Universal Couplers, Statement of Calibration, and Getting Started Guide

DSX CableAnalyzer:

(2) DSX-8000 CableAnalyzer Modules, (2) AxTalk Terminators, Set of Cat 8/Class I Permanent Link Adaptors, Set of Cat 8/Class I Channel Adaptors, DSX Series Coaxial Adapter Set, DSX Patch Cord Test Adapter Set for Category 5e patch cords, DSX Patch Cord Test Adapter Set for Category 6 patch cords, DSX Patch Cord Test Adapter Set for Category 6A patch cords, DSX M12 4-position Channel Adapter Set

CertiFiber Pro Quad OLTS:

(2) CertiFiber Pro Quad OLTS Modules, (4) Sets of 50 µm Multimode EF TRC kits: SC/LC (2 SC/LC, 2 LC/LC), SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC), 4 Sets of 62.5 µm Multimode EF TRC kits: SC/LC (2 SC/LC, 2 LC/LC), SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC), 6 Sets of 9 µm Singlemode TRC kits: SC/SCAPC (2 SC/SCAPC, 2 SCAPC/SCAPC), SC/LCAPC (2 SC/LCAPC, 2 LCAPC/LCAPC), SC/LC (2 SC/LC, 2 LC/LC), SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC), 4 TRC Carry Cases, 4 Sets of Interchange Adapters (LC – installed on units, SC, ST and FC)

OptiFiber Pro Quad OTDR:

OptiFiber Pro Quad OTDR Module, 50 µm Multimode Launch Cords (2 SC/LC, 3 SC/SC, 2 SC/ST, 2 SC/FC, 1 LC/LC, 1 ST/ST, 1 FC/FC), 62.5 µm Multimode Launch Cords (2 SC/LC, 2 SC/SC, 2 SC/ST, 2 SC/FC), 9 µm Singlemode Launch Cords (2 SC/LC, 3 SC/SC, 2 SC/ST, 2 SC/FC, 1 LC/LC, 1 ST/ST, 1 FC/FC, 2 SC/SCAPC, 2 SC/LCAPC), 50 µm Multimode TRC OTDR port saver (SC/SC, LC/LC), 62.5 µm Multimode TRC OTDR port saver (SC/SC, LC/LC), 9 µm Singlemode TRC OTDR port saver (SC/SC, LC/LC), OTDR Source Port Interchange Adapter Sets (LC – installed on unit, SC/ST, FC), (2) OTDR Hanging straps and magnets

Fiber Inspection and Cleaning:

(2) Versiv USB inspection cameras and tips sets, (2) Quick Clean Cleaners (1.25 mm), (2) Quick Clean Cleaners (2.50 mm), Enhanced Fiber Optic Cleaning Kit with Quick Clean cleaners

Fluke Networks DSX2-8-PRO-NW Offers

The DSX CableAnalyzer Series copper cable certifiers enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you’ll be. Unfortunately, there are a lot of things that slow the process down – setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand.

As part of the Versiv cabling certification product family, the DSX CableAnalyzer Series copper cable certifiers provides accurate, error-free certification. In the installation business there are multiple teams, varying media types and multiple testing requirements. The difference between being profitable or not is just a few percentage points. The DSX certifies copper cabling, complies with all standards including Level VI/2G accuracy, making jobs easier to manage, and getting to system acceptance faster. It’s not just for the expert technicians and Project Managers. Individuals of various skill levels can improve the set-up, operation, test reporting, and simultaneously manage diverse projects.

Features

  • Versiv enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
  • LinkWare Live cloud service lets the Project Manager remotely set up the testers, monitor job progress and even location from any smart device
  • ProjX™ management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive™ user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  • LinkWare PC management software provides unmatched analysis of test results and professional test reports
  • The DSX reduces the time required to fix cabling faults with dedicated diagnostics, a simple test that locates the problem

Fluke Networks DSX2-8-PRO-NW Specifications

Copper Certifications
Category 6A / Class EA Test Time 8 Seconds
Category 8 / Class I/II Test Time 16 Seconds
HDTDX/HDTDR Diagnostic Test Times ~3 Seconds
Internal Memory ~5,000 Cat 8 with plots
~12,000 Cat 6A with plots
Level V Accuracy 1 GHz
Level VI Accuracy 2 GHz
Resistance Unbalance Measurement Yes
Shield Integrity Check Yes
TCL Measurement Yes
ELTCTL Measurement Yes
CDNEXT Measurement Yes
CMRL Measurement Yes
Built in Alien XTalk Module Yes
Channel Adapter 2 GHz Range
Permanent Link Adapter 2 GHz Range
Environmental
Operating Temperature 32°F to 113°F (0°C to 45°C)
Storage Temperature -22°F to 140°F (-30°C to 60°C)
Operating Relative Humidity (% RH Without Condensation) 0% to 90%, 32°F to 95°F (0°C to 35°C)
0% to 70%, 95°F to 113°F (35°C to 45°C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Operating Altitude 13,123" (4,000 m)
10,500" (3,200 m) with AC Adapter
EMC EN 61326-1
General Specifications
Autotest Time Full 2-way Autotest of Cat 5e or 6/Class D or E: 7 seconds
Full 2-way Autotest of Cat 6A/Class EA: 8 seconds
Full 2-way Autotest of Cat 8: 16 seconds
Support Test Parameters Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End
Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input Protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with show absorbing overmold
Dimensions Main Versiv unit with DSX module and battery installed: 2.625 x 5.25 x 11.0" (6.67 x 13.33 x 27.94 cm)
Weight Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
Main Unit and Remote Lithium ion battery pack, 7.2 V
Typical Battery Life 8 hours
Charge time Tester off: 4 hours to charge from 10 % capacity to 90 % capacity
Languages Supported English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Traditional Chinese, Czech, Polish, Swedish, Hungarian
Calibration Service center calibration period is 1 year
Click here for complete specifications on the Fluke Networks DSX2-8-PRO-NW

What's included with the Fluke Networks DSX2-8-PRO-NW

Versiv mainframe and Accessories:

(2) Versiv Mainframes, (2) Headsets, (2) Hand Straps, (2) Shoulder Straps, Hard sided Carry Case, (2) Large Duffle Bags, (1) Backpack straps for Versiv Duffle Bag, (2) Versiv stands, USB Interface Cable, (2) AC Chargers, (2) Universal Couplers, Statement of Calibration, and Getting Started Guide

DSX CableAnalyzer:

(2) DSX-8000 CableAnalyzer Modules, (2) AxTalk Terminators, Set of Cat 8/Class I Permanent Link Adaptors, Set of Cat 8/Class I Channel Adaptors, DSX Series Coaxial Adapter Set, DSX Patch Cord Test Adapter Set for Category 5e patch cords, DSX Patch Cord Test Adapter Set for Category 6 patch cords, DSX Patch Cord Test Adapter Set for Category 6A patch cords, DSX M12 4-position Channel Adapter Set

CertiFiber Pro Quad OLTS:

(2) CertiFiber Pro Quad OLTS Modules, (4) Sets of 50 µm Multimode EF TRC kits: SC/LC (2 SC/LC, 2 LC/LC), SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC), 4 Sets of 62.5 µm Multimode EF TRC kits: SC/LC (2 SC/LC, 2 LC/LC), SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC), 6 Sets of 9 µm Singlemode TRC kits: SC/SCAPC (2 SC/SCAPC, 2 SCAPC/SCAPC), SC/LCAPC (2 SC/LCAPC, 2 LCAPC/LCAPC), SC/LC (2 SC/LC, 2 LC/LC), SC/SC (4 SC/SC), SC/ST (2 SC/ST, 2 ST/ST), SC/FC (2 SC/FC, 2 FC/FC), 4 TRC Carry Cases, 4 Sets of Interchange Adapters (LC – installed on units, SC, ST and FC)

OptiFiber Pro Quad OTDR:

OptiFiber Pro Quad OTDR Module, 50 µm Multimode Launch Cords (2 SC/LC, 3 SC/SC, 2 SC/ST, 2 SC/FC, 1 LC/LC, 1 ST/ST, 1 FC/FC), 62.5 µm Multimode Launch Cords (2 SC/LC, 2 SC/SC, 2 SC/ST, 2 SC/FC), 9 µm Singlemode Launch Cords (2 SC/LC, 3 SC/SC, 2 SC/ST, 2 SC/FC, 1 LC/LC, 1 ST/ST, 1 FC/FC, 2 SC/SCAPC, 2 SC/LCAPC), 50 µm Multimode TRC OTDR port saver (SC/SC, LC/LC), 62.5 µm Multimode TRC OTDR port saver (SC/SC, LC/LC), 9 µm Singlemode TRC OTDR port saver (SC/SC, LC/LC), OTDR Source Port Interchange Adapter Sets (LC – installed on unit, SC/ST, FC), (2) OTDR Hanging straps and magnets

Fiber Inspection and Cleaning:

(2) Versiv USB inspection cameras and tips sets, (2) Quick Clean Cleaners (1.25 mm), (2) Quick Clean Cleaners (2.50 mm), Enhanced Fiber Optic Cleaning Kit with Quick Clean cleaners

More Fluke Networks Products