Fluke Networks DSX-5000Oi Cable Analyzer with OptiFiber Quad OTDR Inspection

Model: DSX-5000Oi | Order No: DSX-5000OI INTL | UPC: 754082138624

Fluke Networks DSX-5000Oi Cable Analyzer with OptiFiber Quad OTDR Inspection

Model: DSX-5000Oi | Order No: DSX-5000OI INTL | UPC: 754082138624

Versiv modular design supports copper certification, fiber loss, OTDR testing and Wi-Fi analysis. Unmatched speed for Cat 6A, Class FA and all current standards. ProjX System manages job requirements making sure tests are completed correctly. The OptiFiber Quad OTDR Inspection has a simple smartphone user interface and powerful features. It can turn anyone into an efficient fiber troubleshooter or installer. Quad Modules with Inspection Kit.

Versiv modular design supports copper certification, fiber loss, OTDR testing and Wi-Fi analysis. Unmatched speed for Cat 6A, Class FA and all current standards. ProjX System manages job requirements making sure tests are completed correctly. The OptiFiber Quad OTDR Inspection has a simple smartphone user interface and powerful features. It can turn anyone into an efficient fiber troubleshooter or installer. Quad Modules with Inspection Kit.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Fluke Networks DSX2-5000QI Cable Analyzer with Quad OLTS-

Fluke Networks DSX2-5000QI Cable Analyzer with Quad OLTS

Model: DSX2-5000QI

Provides error-free copper cable certification for testing Cat6A, Class FA and QUAD OLTS certification. ProjX management system easily manages complex jobs. Versiv platform supports modules for fiber testing and Ethernet troubleshooting.


Fluke Networks DSX2-5000QI/G CableAnalyzer Copper Certifier with WiFi, 1 GHz, Quad OLTS, fiber inspection-

Fluke Networks DSX2-5000QI/G CableAnalyzer Copper Certifier with WiFi, 1 GHz, Quad OLTS, fiber inspection

Model: DSX2-5000QI/GLD

Certifies copper cable up to CAT 6A / Class FA / 1 GHz in just 8 seconds featuring ProjX™ management system and Taptive™ for an accelerated copper cable certification pocess. This tester set includes the Versive mainframe, cable analyzer modules, Quad OLTS modules and fiber inspection kit.


Not what you're looking for? Let’s do a search and help you find what you need.


Fluke Networks DSX-5000Oi Offers

The DSX-5000 CableAnalyzer improves the efficiency of copper certification with unmatched speed for testing Cat 6A and Class FA while meeting draft IEC Level V – the most stringent accuracy requirement. The ProjX Management System helps ensure jobs are done correctly the first time and helps tracks progress from set-up to systems acceptance. Versiv platform supports modules for fiber testing (Both OLTS and OTDR) and Wi-Fi Analysis and Ethernet troubleshooting. The platform is easily upgradeable to support future standards. Troubleshoot faults faster with the Taptive user interface which graphically displays the source of failures including crosstalk, return loss and shield faults. Analyze test results and create professional test reports using LinkWare™ Management Software.

Fluke Networks' DSX-5000 CableAnalyzer is Intertek (ETL) Verified in accordance with the IEC-61935-1 specifications for accuracy Level IV, and draft accuracy Level V, and in accordance with the ANSI/TIA-1152 specifications for Level IIIe.

Features

  • Versiv enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
  • ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  • LinkWare management software provides unmatched analysis of test results and professional test reports
  • The DSX reduces the time required to fix cabling faults with Dedicated Diagnostics, a simple test that locates the problem
  • Compliant with proposed ISO (IEC WG9 Standard IEC61935-1) Level V accuracy requirements to 1000 MHz
  • Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) – IEC61935-1 & 11801-1-4, IEEE 802.3af, IEEE 802.3at, ANSI/TIA-568-C.2
  • Next generation balance drafts – IEEE 802.3, TIA TR42.7

Fluke Networks DSX-5000Oi Specifications

Cable Types
Shielded and Unshielded Pair LAN Cabling TIA Category 3, 4, 5, 5e, 6, 6A: 100 Ω ISO/IEC Class C, D, E, EA, F, and FA: 100 Ω and 120 Ω
Standard Link Interface Adapters
Permanent Link Adapters Plug type: shielded RJ45
Optional Plug type: Tera
Channel Adapters Jack type: shielded RJ45
Optional Jack type: Tera
Test Standards
TIA Category 3, 4, 5, 5e, 6, 6A per TIA 568-C.2
ISO/IEC Class C and D, E, Ea, F, FA certification per ISO/IEC 11801:2002 and amendments
Maximum Frequency 1200 MHz
General Specifications
Speed of Autotest Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds
Full 2-way Autotest of Category 6A/Class EA: 10 seconds
Support Test Parameters (The selected test standard determines the test parameters and the frequency range of the tests) Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input Protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with show absorbing overmold
Dimensions Main Versiv unit with DSX-5000 module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Weight Main Versiv unit with DSX-5000 module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote Lithium ion battery pack, 7.2 V
Typical battery life 8 hours
Charge time* Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supported English, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese
Calibration Service center calibration period is 1 year
Environment Specifications
Operating Temperature 32 to 113°F (0 to 45°C)
Storage Temperature -4 to 122°F (-20 to 50°C)
Operating relative humidity 0% to 90%, 32 to 95°F (0 to 35°C)
0% to 70%, 95 to 113°F (35 to 45°C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 2nd Edition + Amendments 1, 2
Operating altitude 13,123 ft (4,000 m)
EMC EN 61326-1
Performance Specifications
Category 6A/Class EA test modes (or lower link categories) DSX-5000 CableAnalyzer modules exceed with Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Class FA test modes DSX-5000 CableAnalyzer modules exceed Level V requirements as in the draft 4th edition of IEC 61935-1.
Length of Twisted Pair Cabling Without Remote
Range 800 m (2600 ft)
Resolution 0.1 m or 1 ft
Accuracy ± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m
Range 150 m (490 ft)
Resolution 0.1 m or 1 ft
Accuracy ± (0.3 m + 2 %)
Propagation Delay Without Remote
Range 4000 ns
Resolution 1 ns
Accuracy ± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns
Propagation Delay With Remote
Range 750 ns
Resolution 1 ns
Accuracy ± (2 ns + 2 %)
Delay Skew
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy ± 10 ns
DC Loop Resistance Test
Range 0 Ω to 540 Ω
Resolution 0.1 Ω
Accuracy ± (1 Ω + 1 %)
Overload recovery time Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.
Click here for complete specifications on the Fluke Networks DSX-5000Oi

What's included with the Fluke Networks DSX-5000Oi

  • Versiv Mainframe & Remote
  • OptiFiber Pro Quad OTDR module
  • CertiFiber Pro Quad OLTS modules (2)
  • HandStraps (2)
  • Shoulder Straps (2)
  • Carry Cases (2)
  • USB Interface Cable
  • Versiv Open Source Software CD
  • AC Chargers (2)
  • OneClick Cleaners (1.25/2.50 mm) (2)
  • SC/LC Multimode Launch Cables—50 µm (2)
  • SC/LC Singlemode Launch Cables—9 µm (2)
  • OTDR source port interchangeable LC adapters (2)
  • USB Fiber Inspection Video Probe with 4 Tips
  • SC/SC Simplex Adaptor
  • LC/LC Simplex Adaptor (2)
  • SC/LC EF-compliant MM TRC Kit 50 µm
  • TRC Carry Case
  • Launch Fiber Hanging straps and magnets (2)
  • Getting Started Guide

Click on a category to view a selection of compatible accessories with the Fluke Networks DSX-5000Oi Cable Analyzer with OptiFiber Quad OTDR Inspection.

Fluke Networks DSX-CHA004S Cat 6A/Class EA Channel Adapter Set DSX-CHA004S
DSX Cat 6A/Class EA channel adapter set.




Fluke Networks DSX-PLA004S Cat 6A/Class EA Permanent Link Adapter Set DSX-PLA004S
DSX Cat 6A/Class EA permanent link adapter set.




Fluke Networks DSX-PLA011S Cat 7A/Class FA Permanent Link Adapter Set DSX-PLA011S
DSX TERA, Cat 7/Class FA permanent link adapter set.





Fluke Networks DSX-REFMOD Reference Modules DSX-REFMOD
Set of 2 Reference Modules for the DSX-5000 Cable Analyzer.




Fluke Networks DSX-5000Oi Offers

The DSX-5000 CableAnalyzer improves the efficiency of copper certification with unmatched speed for testing Cat 6A and Class FA while meeting draft IEC Level V – the most stringent accuracy requirement. The ProjX Management System helps ensure jobs are done correctly the first time and helps tracks progress from set-up to systems acceptance. Versiv platform supports modules for fiber testing (Both OLTS and OTDR) and Wi-Fi Analysis and Ethernet troubleshooting. The platform is easily upgradeable to support future standards. Troubleshoot faults faster with the Taptive user interface which graphically displays the source of failures including crosstalk, return loss and shield faults. Analyze test results and create professional test reports using LinkWare™ Management Software.

Fluke Networks' DSX-5000 CableAnalyzer is Intertek (ETL) Verified in accordance with the IEC-61935-1 specifications for accuracy Level IV, and draft accuracy Level V, and in accordance with the ANSI/TIA-1152 specifications for Level IIIe.

Features

  • Versiv enables users to accomplish more than ever before with a cable tester, by accelerating every step of the testing process
  • ProjX management system eases tasks from initial set-up of a job to system acceptance. It eliminates redundant steps, and ensures that all tests are completed correctly the first time, and every time
  • Taptive user interface puts advanced data analysis and easy set-up and operation at the fingertips of technicians of all skill levels
  • LinkWare management software provides unmatched analysis of test results and professional test reports
  • The DSX reduces the time required to fix cabling faults with Dedicated Diagnostics, a simple test that locates the problem
  • Compliant with proposed ISO (IEC WG9 Standard IEC61935-1) Level V accuracy requirements to 1000 MHz
  • Supports the complete suite of Resistance Unbalance standards needed for Power over Ethernet (PoE) – IEC61935-1 & 11801-1-4, IEEE 802.3af, IEEE 802.3at, ANSI/TIA-568-C.2
  • Next generation balance drafts – IEEE 802.3, TIA TR42.7

Fluke Networks DSX-5000Oi Specifications

Cable Types
Shielded and Unshielded Pair LAN Cabling TIA Category 3, 4, 5, 5e, 6, 6A: 100 Ω ISO/IEC Class C, D, E, EA, F, and FA: 100 Ω and 120 Ω
Standard Link Interface Adapters
Permanent Link Adapters Plug type: shielded RJ45
Optional Plug type: Tera
Channel Adapters Jack type: shielded RJ45
Optional Jack type: Tera
Test Standards
TIA Category 3, 4, 5, 5e, 6, 6A per TIA 568-C.2
ISO/IEC Class C and D, E, Ea, F, FA certification per ISO/IEC 11801:2002 and amendments
Maximum Frequency 1200 MHz
General Specifications
Speed of Autotest Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds
Full 2-way Autotest of Category 6A/Class EA: 10 seconds
Support Test Parameters (The selected test standard determines the test parameters and the frequency range of the tests) Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input Protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with show absorbing overmold
Dimensions Main Versiv unit with DSX-5000 module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Weight Main Versiv unit with DSX-5000 module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote Lithium ion battery pack, 7.2 V
Typical battery life 8 hours
Charge time* Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supported English, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese
Calibration Service center calibration period is 1 year
Environment Specifications
Operating Temperature 32 to 113°F (0 to 45°C)
Storage Temperature -4 to 122°F (-20 to 50°C)
Operating relative humidity 0% to 90%, 32 to 95°F (0 to 35°C)
0% to 70%, 95 to 113°F (35 to 45°C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 2nd Edition + Amendments 1, 2
Operating altitude 13,123 ft (4,000 m)
EMC EN 61326-1
Performance Specifications
Category 6A/Class EA test modes (or lower link categories) DSX-5000 CableAnalyzer modules exceed with Level IIIe requirements of TIA 1152 and Level IV of IEC 61935-1.
Class FA test modes DSX-5000 CableAnalyzer modules exceed Level V requirements as in the draft 4th edition of IEC 61935-1.
Length of Twisted Pair Cabling Without Remote
Range 800 m (2600 ft)
Resolution 0.1 m or 1 ft
Accuracy ± (0.3 m + 2 %); 0 m to 150 m
± (0.3 m + 4 %); 150 m to 800 m
Range 150 m (490 ft)
Resolution 0.1 m or 1 ft
Accuracy ± (0.3 m + 2 %)
Propagation Delay Without Remote
Range 4000 ns
Resolution 1 ns
Accuracy ± (2 ns + 2 %); 0 ns to 750 ns
± (2 ns + 4 %); 750 ns to 4000 ns
Propagation Delay With Remote
Range 750 ns
Resolution 1 ns
Accuracy ± (2 ns + 2 %)
Delay Skew
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy ± 10 ns
DC Loop Resistance Test
Range 0 Ω to 540 Ω
Resolution 0.1 Ω
Accuracy ± (1 Ω + 1 %)
Overload recovery time Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.
Click here for complete specifications on the Fluke Networks DSX-5000Oi

What's included with the Fluke Networks DSX-5000Oi

  • Versiv Mainframe & Remote
  • OptiFiber Pro Quad OTDR module
  • CertiFiber Pro Quad OLTS modules (2)
  • HandStraps (2)
  • Shoulder Straps (2)
  • Carry Cases (2)
  • USB Interface Cable
  • Versiv Open Source Software CD
  • AC Chargers (2)
  • OneClick Cleaners (1.25/2.50 mm) (2)
  • SC/LC Multimode Launch Cables—50 µm (2)
  • SC/LC Singlemode Launch Cables—9 µm (2)
  • OTDR source port interchangeable LC adapters (2)
  • USB Fiber Inspection Video Probe with 4 Tips
  • SC/SC Simplex Adaptor
  • LC/LC Simplex Adaptor (2)
  • SC/LC EF-compliant MM TRC Kit 50 µm
  • TRC Carry Case
  • Launch Fiber Hanging straps and magnets (2)
  • Getting Started Guide

Click on a category to view a selection of compatible accessories with the Fluke Networks DSX-5000Oi Cable Analyzer with OptiFiber Quad OTDR Inspection.

Fluke Networks DSX-CHA004S Cat 6A/Class EA Channel Adapter Set DSX-CHA004S
DSX Cat 6A/Class EA channel adapter set.




Fluke Networks DSX-PLA004S Cat 6A/Class EA Permanent Link Adapter Set DSX-PLA004S
DSX Cat 6A/Class EA permanent link adapter set.




Fluke Networks DSX-PLA011S Cat 7A/Class FA Permanent Link Adapter Set DSX-PLA011S
DSX TERA, Cat 7/Class FA permanent link adapter set.





Fluke Networks DSX-REFMOD Reference Modules DSX-REFMOD
Set of 2 Reference Modules for the DSX-5000 Cable Analyzer.




More Fluke Networks Products