EV Charger Test Kit with EV45-NACS, DM286 Multimeter and Test Leads.
EV Charger Test Kit with EV45-NACS, DM286 Multimeter and Test Leads.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Chargers and Power Adapters category for similar products.
Or let's do a search and help you find what you need:
Features
Applications
Electrical Measurement | |
PE Pre-Test | Pass / Fault (>50 V AC/DC between PE conductor and touch sensor) |
PP State Indication | Open, 13 A, 20 A, 32 A, 63 A |
CP State Simulation | A (Disconnected) , B (Connected) , C (Charging), D (Charging w/ ventilation), E (Error) |
Voltage Phase Indication | L1, L2 |
CP Error (E State) Simulation | Pass / Fault (CP signal short-circuited to PE) |
PE Error Simulation | Pass / Fault (Interruption of PE conductor) |
RCD/CCID Trip Test | Pass / Fault (Test RCD/CCID activation once tripped) |
Outputs (For Test Purpose Only) | |
Measuring Terminals L1, PE, N | Maximum 250 V (Single Phase), 50/60 Hz, CAT II 300 V, Maximum 10 A |
Outputs (Optional Meters) | |
Connect to CMM (DM286) | CP State C / D for AC Voltage with Hz measurement |
Connect to Insulation Tester (IM75-2) | CP State B for EV cable Insulation Test |
Power System | |
Battery | 4 × AA Alkaline batteries |
Battery Life | Approximately 100 hours, with alkaline batteries |
General Information | |
NACS Connector (Built-In) | Connector for NACS Station |
Accessory Converter | NACS to SAE J1772 Type 1 |
Category Rating | CAT II-300 V |
Warranty | Limited 3-Year Warranty |
Certifications | |
Certifications | ETL, CE |
Safety Standards | IEC 61010-1 CAT II-300 V |
EMC Standards | EN61326-1 |
Environmental Data | |
Operating Ambient Temperatures and Relative Humidity | −10°C to 30°C (14°F to 86°F), <85% RH 30°C to 40°C (86°F to 104°F), <75% RH 40°C to 50°C (104°F to 122°F), <45% RH |
Storage Temperature and RH | −20°C to 60°C (−4°F to 140°F), 0 to 80% RH (without batteries) |
Operating Altitude | 2000 m (6560') |
Pollution Degree | 2 |
Meter Physcial Data | |
Dimensions | 237 mm × 65 mm × 56 mm (9.33" × 2.56" × 2.20") |
Weight | 600 g (1.32 lbs) |
Electrical Measurement | |
PE Pre-Test | Pass / Fault (>50 V AC/DC between PE conductor and touch sensor) |
PP State Indication | Open, 13 A, 20 A, 32 A, 63 A |
CP State Simulation | A (Disconnected) , B (Connected) , C (Charging), D (Charging w/ ventilation), E (Error) |
Voltage Phase Indication | L1, L2 |
CP Error (E State) Simulation | Pass / Fault (CP signal short-circuited to PE) |
PE Error Simulation | Pass / Fault (Interruption of PE conductor) |
RCD/CCID Trip Test | Pass / Fault (Test RCD/CCID activation once tripped) |
Outputs (For Test Purpose Only) | |
Measuring Terminals L1, PE, N | Maximum 250 V (Single Phase), 50/60 Hz, CAT II 300 V, Maximum 10 A |
Outputs (Optional Meters) | |
Connect to CMM (DM286) | CP State C / D for AC Voltage with Hz measurement |
Connect to Insulation Tester (IM75-2) | CP State B for EV cable Insulation Test |
Power System | |
Battery | 4 × AA Alkaline batteries |
Battery Life | Approximately 100 hours, with alkaline batteries |
General Information | |
NACS Connector (Built-In) | Connector for NACS Station |
Accessory Converter | NACS to SAE J1772 Type 1 |
Category Rating | CAT II-300 V |
Warranty | Limited 3-Year Warranty |
Certifications | |
Certifications | ETL, CE |
Safety Standards | IEC 61010-1 CAT II-300 V |
EMC Standards | EN61326-1 |
Environmental Data | |
Operating Ambient Temperatures and Relative Humidity | −10°C to 30°C (14°F to 86°F), <85% RH 30°C to 40°C (86°F to 104°F), <75% RH 40°C to 50°C (104°F to 122°F), <45% RH |
Storage Temperature and RH | −20°C to 60°C (−4°F to 140°F), 0 to 80% RH (without batteries) |
Operating Altitude | 2000 m (6560') |
Pollution Degree | 2 |
Meter Physcial Data | |
Dimensions | 237 mm × 65 mm × 56 mm (9.33" × 2.56" × 2.20") |
Weight | 600 g (1.32 lbs) |