HS36 Expandable True RMS HVAC/R Multimeter with backlight takes readings for Continuity, Capacitance, Alternating Current/Direct Current Volts, Direct Current, Frequency, Resistance, and Temperature. This multimeter has a bright backlit LCD screen and magnetic holster for hands-free operation. It has Non-contact voltage capabilities as well as an Auto-off function and is packed with the features HVAC/R technicians need.
HS36 Expandable True RMS HVAC/R Multimeter with backlight takes readings for Continuity, Capacitance, Alternating Current/Direct Current Volts, Direct Current, Frequency, Resistance, and Temperature. This multimeter has a bright backlit LCD screen and magnetic holster for hands-free operation. It has Non-contact voltage capabilities as well as an Auto-off function and is packed with the features HVAC/R technicians need.
Features
| Frequency | |
| Ranges | 4k, 40k, 400k, 4M, 40MHz |
| Resolution | 1Hz |
| Accuracy | ±(0.1% rdg + 3 dgts) |
| Sensitivity | 10Hz ~ 4MHz: > 1Vrms 4MHz ~ 40MHz: > 2Vrms, <5Vrms |
| Minimum pulse width | > 25ns |
| Duty cycle limits | > 30% and < 70% |
| Overload protection | 500V DC or AC rms |
| Continuity | |
| Audible indication | Less than 40Ω |
| Response time | 500ms (Green LED will be on continuously) |
| Overload protection | 500V DC or AC rms |
| Capacitance | |
| Range | 400μF |
| Resolution | 0.1μF |
| Accuracy | ±(3% rdg + 5 dgts) |
| Overload protection | 500V DC or AC rms |
| DC Volts | |
| Ranges | 400mV, 4000mV, 40V, 400V, 600V |
| Resolution | 0.1mV |
| Accuracy | ±(0.5% rdg + 2 dgt) |
| Input impedance | 3MΩ on V inputs, 10MΩ on mV input |
| Overload protection | 600V DC or AC rms |
| Transient protection | 6kV for 10μ sec |
| AC Volts (50Hz to 500Hz) |
|
| Ranges | 400mV, 4V, 40V, 400V, 600V |
| Conversion | True RMS |
| Resolution | 0.1mV |
| Accuracy | ±(1.2% rdg + 5 dgts) 50Hz ~ 60Hz on 400mV range ±1.5% rdg + 5 dgts) ±(2% rdg + 5 dgts) on 600V range |
| Input impedance | 3MΩ |
| Overload protection | 600V DC or AC rms |
| Transient protection | 6kV for 10μ sec |
| Resistance | |
| Ranges | 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ |
| Resolution | 0.1Ω |
| Accuracy | ±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges ±(1.5% rdg + 4 dgts) on 4MΩ range ±(3.0% rdg + 5 dgts) on 40MΩ range |
| Open circuit volts | -0.45 V DC typical, (-1.2 V DC on 400Ω range) |
| Overload protection | 500 V DC or AC rms |
| Temperature | |
| Range | -30 to 1000°F (-34 to 538°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±1°F, 32 to 120°F (0 to 49°C) ±1% + 1.5°F, -4 to 750°F (-20 to 399°C) ±2% + 4°F, -30 to -4°F (-34 to -20°C) ±2% + 4°F, 750 to 1000°F (399 to 538°C) |
| Sensor type | K-type thermocouple |
| Overload protection | 60 V DC or 30 V AC rms |
| DC current | |
| Ranges | 400μA, 4000μA |
| Resolution | 0.1μA |
| Accuracy | ±(1.0% rdg + 2 dgt) |
| Voltage burden | 1V, (8V on 4000μA range) |
| Overload protection | 500V DC or AC rms |
| General Specifications | |
| Display | 3-3/4 digit liquid crystal display (LCD) with a maximum reading of 3999 |
| Analog bar graph | 41 segments with measurements 20 times per second |
| Overrange | "OL" mark indication |
| Auto power off | 30 minutes |
| Operating enviroment | 32 to 122°F (0 to 50°C) at <70% R.H. |
| Storage temperature | -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed |
| Accuracy | Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°C), <75% relative humidity |
| Temperature Coefficient | 0.1x(specified accuracy) per °F/°C. 32 to 64°F (0 to 18°C) 82 to 122°F (28 to 50°C) |
| Power | Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
| Battery life | 300 hours typical with alkaline |
| Accessories | One pair test leads, one pair alligator clips, k-type thermocouple, 9V battery (installed), and operating instructions |
| Safety | UL, CE, Cat III 600V, UL61010-1, IEC/EN61010-1 |
Click on a category to view a selection of compatible accessories with the Fieldpiece HS36 HVAC/R Expandable True RMS Stick Multimeter.
| Frequency | |
| Ranges | 4k, 40k, 400k, 4M, 40MHz |
| Resolution | 1Hz |
| Accuracy | ±(0.1% rdg + 3 dgts) |
| Sensitivity | 10Hz ~ 4MHz: > 1Vrms 4MHz ~ 40MHz: > 2Vrms, <5Vrms |
| Minimum pulse width | > 25ns |
| Duty cycle limits | > 30% and < 70% |
| Overload protection | 500V DC or AC rms |
| Continuity | |
| Audible indication | Less than 40Ω |
| Response time | 500ms (Green LED will be on continuously) |
| Overload protection | 500V DC or AC rms |
| Capacitance | |
| Range | 400μF |
| Resolution | 0.1μF |
| Accuracy | ±(3% rdg + 5 dgts) |
| Overload protection | 500V DC or AC rms |
| DC Volts | |
| Ranges | 400mV, 4000mV, 40V, 400V, 600V |
| Resolution | 0.1mV |
| Accuracy | ±(0.5% rdg + 2 dgt) |
| Input impedance | 3MΩ on V inputs, 10MΩ on mV input |
| Overload protection | 600V DC or AC rms |
| Transient protection | 6kV for 10μ sec |
| AC Volts (50Hz to 500Hz) |
|
| Ranges | 400mV, 4V, 40V, 400V, 600V |
| Conversion | True RMS |
| Resolution | 0.1mV |
| Accuracy | ±(1.2% rdg + 5 dgts) 50Hz ~ 60Hz on 400mV range ±1.5% rdg + 5 dgts) ±(2% rdg + 5 dgts) on 600V range |
| Input impedance | 3MΩ |
| Overload protection | 600V DC or AC rms |
| Transient protection | 6kV for 10μ sec |
| Resistance | |
| Ranges | 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ |
| Resolution | 0.1Ω |
| Accuracy | ±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges ±(1.5% rdg + 4 dgts) on 4MΩ range ±(3.0% rdg + 5 dgts) on 40MΩ range |
| Open circuit volts | -0.45 V DC typical, (-1.2 V DC on 400Ω range) |
| Overload protection | 500 V DC or AC rms |
| Temperature | |
| Range | -30 to 1000°F (-34 to 538°C) |
| Resolution | 0.1°F/°C |
| Accuracy | ±1°F, 32 to 120°F (0 to 49°C) ±1% + 1.5°F, -4 to 750°F (-20 to 399°C) ±2% + 4°F, -30 to -4°F (-34 to -20°C) ±2% + 4°F, 750 to 1000°F (399 to 538°C) |
| Sensor type | K-type thermocouple |
| Overload protection | 60 V DC or 30 V AC rms |
| DC current | |
| Ranges | 400μA, 4000μA |
| Resolution | 0.1μA |
| Accuracy | ±(1.0% rdg + 2 dgt) |
| Voltage burden | 1V, (8V on 4000μA range) |
| Overload protection | 500V DC or AC rms |
| General Specifications | |
| Display | 3-3/4 digit liquid crystal display (LCD) with a maximum reading of 3999 |
| Analog bar graph | 41 segments with measurements 20 times per second |
| Overrange | "OL" mark indication |
| Auto power off | 30 minutes |
| Operating enviroment | 32 to 122°F (0 to 50°C) at <70% R.H. |
| Storage temperature | -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed |
| Accuracy | Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°C), <75% relative humidity |
| Temperature Coefficient | 0.1x(specified accuracy) per °F/°C. 32 to 64°F (0 to 18°C) 82 to 122°F (28 to 50°C) |
| Power | Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 |
| Battery life | 300 hours typical with alkaline |
| Accessories | One pair test leads, one pair alligator clips, k-type thermocouple, 9V battery (installed), and operating instructions |
| Safety | UL, CE, Cat III 600V, UL61010-1, IEC/EN61010-1 |