Fieldpiece CAT85 Combustion Analyzer HydroCycle Kit

Model: CAT85 | UPC: 872641005115

Fieldpiece CAT85 Combustion Analyzer HydroCycle Kit

Model: CAT85 | UPC: 872641005115

CAT85 is an innovative residential/commercial combustion analyzer for HVAC/R professionals to assess heating systems, draft pressure, and temperatures to support the overall fuel efficiency and safety of furnaces. The CAT85 gas analyzer accurately measures O2, CO, CO2, flue temperature, air temperature, and draft/gas pressure. Fieldpiece's combustion analyzer with improved combustion analysis through optimized thermal processes helps technicians assess and monitor combustion data during installation, maintenance, and repairs.

CAT85 is an innovative residential/commercial combustion analyzer for HVAC/R professionals to assess heating systems, draft pressure, and temperatures to support the overall fuel efficiency and safety of furnaces. The CAT85 gas analyzer accurately measures O2, CO, CO2, flue temperature, air temperature, and draft/gas pressure. Fieldpiece's combustion analyzer with improved combustion analysis through optimized thermal processes helps technicians assess and monitor combustion data during installation, maintenance, and repairs.

Sale Price $1997.50 USD
Regular Price $2350.00 USD
Availability 1 in Stock
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your CAT85 Combustion Analyzer HydroCycle Kit

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your CAT85 Combustion Analyzer HydroCycle Kit

Fieldpiece CAT85 Offers

The CAT85K2 flue analyzer features Fieldpiece patent pending SensorVault™ technology that offers a lower cost of ownership. This patent pending feature extends sensor life by sealing the sensor from oxygen in the air during storage. These sensors are warrantied for four years and are field replaceable.
A built-in dual-port manometer is included on the Fieldpiece CAT85K2 commercial combustion analyzer to measure gas pressures, a gas regulator operation, and even measure total external static pressure of a heating appliance.
The CAT85K2 also features live draft pressure measurements allowing the HVAC Professional to view the effects adjustments have on the draft pressure in real-time.
The patent pending HydroCycle™ Pump technology is included on Fieldpiece CAT85K2 flue probe that automatically separates and returns accumulated water to the flue.
The Fieldpiece CAT85K2 utilizes a convenient one-touch power on-button; pressing the power button initializes the short start-up period and unlocks the new SensorVault™ technology. The combustion testing starts automatically after the startup is complete.
The Fieldpiece combustion analyzer is intuitive, user-friendly, and makes data simple to scan. HVAC professionals will appreciate the clear view of all information on a single screen, the easy-to-navigate touchscreen display design, and the simple user interface.
The CAT85K2 combustion analyzer features a large, high-contrast 5.5” touchscreen display for viewing measurements. Save your customer data with dedicated fields for client information, and a live trend report is available with O2, CO, and CO2 readings, for more advanced diagnosis.
The Fieldpiece combustion analyzer is designed to handle the rigors of any job site with its thick over-molded construction, a long flexible hose/cord, and a padded hardline carrying case with multiple inserts for accessories. Plus, the magnetic back lets you work hands-free. The combustion analyzer comes with a rechargeable battery that lasts up to seven hours and enables charges in trucks between jobs and overnight.
The CAT85K2 is compatible with the Fieldpiece Job Link System App featuring its industry-leading 1000-foot wireless range. The Fieldpiece Job Link App allows technicians to view trends, draft pressure, and customer details seamlessly and conveniently.
A wireless printer (CATPR) is included with the Fieldpiece CAT85K2 for jobsites that require documentation printouts. If you would like the combustion analyzer without a printer, check out the Fieldpiece CAT85.

Features

  • Accurately measure O2, CO, CO2, draft pressure
  • Built-in dual manometer ports
  • HydroCycle Pump technology
  • Real-time live draft pressure
  • Large 5.5 touchscreen display with one-touch power on
  • SensorVault™ Technology
  • One-touch power button
  • Rechargeable Battery
  • In-use USB-C Charging
  • Field Replaceable Smart Sensors
  • Durable Hard Lined Case
  • Lower cost of ownership with four-year sensor warranty
  • Patent pending SensorVault™ Technology prolongs sensor life
  • Built-in manometer
  • HydroCycle™ Pump technology
  • Dual Manometer Ports
  • Large Intuitive Touchscreen
  • Powerful Trending
  • Inline Water Trap
  • Job Link® System App Compatible industry-leading 1000' wireless range
  • Wireless Printer (CATPR) Compatible (not included)

Top 5 Reasons to Own Fieldpiece CAT85 Combustion Analyzer:

  • SensorVault technology seals off sensors when not in use and extends sensor life
  • Sensors are warrantied for 4-years and are field replaceable
  • HydroCycle pump automatically returns water to the flue, eliminating the water trap
  • Built-in, dual-port manometer means one less tool to carry

Applications

  • Residential / Commercial HVAC/R

Fieldpiece CAT85 Specifications

Sensors
Temperature Type K rod thermocouple (fixed), < 30 seconds (T90)
Oxygen % Electrochemical (replaceable), < 30 seconds (T90), 30% Oxygen
Carbon Monoxide PPM Electrochemical (replaceable), < 90 seconds (T90), 10000 ppm Carbon Monoxide
Pressure (Probe) Piezoresistive pressure sensor, < 10 seconds (T90), 4.0 inWC will cause damage
Pressure (Ports) Silicon pressure sensors, < 10 seconds (T90), 11.6 psig (321 inWC) causes damage
Test Parameters
Stack Temperature 0.1°F (0.1°C): 32 to 752°F (0 to 400°C)
±2.5°F: 32 to 212°F
±(3.6°F or 1.5%rdg): 213 to 752°F
±1.4°C: 0 to 100°C
±(2.0°C or 1.5%rdg): 101 to 400°C
Oxygen O2 0 to 21 vol.%, 0.1 vol.%, ±0.3 vol.%
Carbon Monoxide CO 0 to 4000 ppm, 1 ppm, ±20 ppm [0 to 400 ppm], ±5%rdg [401 to 2000 ppm], ±10%rdg [2001 to 4000 ppm]
Draft Pressure 0 to ±0.8 inWC, 0.01 inWC, ±0.02 inWC
CO Air Free (Calculated) 0 to 4000 ppm, 1 ppm
CO2 (Calculated) 0 to CO2max vol.%, 0.1 vol.%
Excess Air (Calculated) 0 to 999%, ±0.1 vol.%
Efficiency (Calculated) 0 to 100%, 0.1%
qA (Calculated) 0 to 25%, 0.1%
Dew Point (Calculated) 32 to 212°F; 0 to 100°C, 0.1°F; 0.1°C
Primary Air Temp 0.1°F (0.1°C): 32 to 212°F (0 to 100°C)
±2.5°F: 32 to 212°F
±1.4°C: 0 to 100°C
Ambient CO 0 to 200 ppm, 1 ppm, ±20 ppm
Manometer 0.01 inWC: 0 to ±40 inWC
±0.2 inWC: 0 to ±20 inWC
±1%rdg: ±(20.1 to 40.0 inWC)
Fuel Pressures 0.01 inWC: 0 to 40 inWC
±0.2 inWC: 0 to 20 inWC
±1%rdg: 20.1 to 40.0 inWC
General Technical Data
Display Touchscreen TFT LCD (5.5 in diagonal)
Probe Size 10.7 in (272 mm) length, 0.32 in (8.0 mm) diameter
Accuracy Stated accuracies at 23°C ±5°C, <75% R.H.
Battery Type 3.7 VDC (nominal), 6400mAh, non-replaceable
Battery Life 7 hours typical (pump running 80% of the time)
Charge Time < 7 hours typical at 5V/2A DC power
Charging Port USB-C (Usable when connected to power.)
Memory 1000 jobs (approx.)
Warm Up Time 45 seconds (90 seconds near freezing)
Operating Environment 14°F to 104°F (-10°C to 40°C); < 75% RH (non-condensing)
Storage Temperature -4°F to 140°F (-20°C to 60°C); < 80% RH
Weight 39.5 oz (1120 g) with probe
Wireless Range 1000 feet (305 meters)
Fuel Types Natural Gas, Propane (LPG), Oil #2 (Light), Oil #6 (Heavy), Biofuel, Coal, Coal Town Gas, Coking Oven Gas, KOKS, Custom (x3)
Warranty 1 year (4 years sensors only)
Job Link® System Minimum BLE 4.0 devices running iOS 7.1 or Android™ Kitkat 4.4
Printer Fieldpiece Wireless Thermal Printer (model CATPR) (not included)
Certifications FCC ID: 2ALHRCATX5, IC: Industry Canada, IC: 22518-CATX5, Waste Electrical and Electronic Equipment

What's included with the Fieldpiece CAT85

  • CAT85 Combustion Analyzer (including probe)
  • 2 x Cones - RCONE3
  • 10 x Filters - RFC10
  • USB-C Charging Cable
  • Hard-Lined Carrying Case - ANC85
  • Operator's Manual
  • One-Year Device Warranty
  • Four-Year Sensor Warranty

Click on a category to view a selection of compatible accessories with the Fieldpiece CAT85 Combustion Analyzer HydroCycle Kit.

Fieldpiece BG36 Inspection Tool Bag BG36
Designed to carry every tool a technician needs for everyday call, the Fieldpiece BG36 is easy to carry and has an easy open pop top to protect your tools during rainy weather. The base of the bag is also weather-protected and keeps the bag standing upright during use.




Fieldpiece BG44 Tool Bag for HVAC/R Technician BG44
For the most common HVAC/R tools used in the field every day, BG44 has a place for everything. Fieldpiece BG44 Tool Bag for HVAC/R Technicians is the ultimate tool bag designed for HVAC/R professionals and general handymen. It features padded pockets for more sensitive equipment, a magnetic tray for quick and easy storage, straps for electrical tape and water bottles, and single strap carrying for convenience and speed. It also has a tough, elevated rack with slots to hold meters, screwdrivers, wrenches, etc. The elevated rack keeps everything in place and helps keep everything visible so nothing is ever lost.




Fieldpiece CATPR Wireless Thermal Printer CATPR
CATPR Wireless Thermal PrinterThe Fieldpiece CATPR is an easy-to-use, compact, wireless thermal printer compatible with the combustion analyzers CAT45 and CAT85.




Fieldpiece CAT85 Offers

The CAT85K2 flue analyzer features Fieldpiece patent pending SensorVault™ technology that offers a lower cost of ownership. This patent pending feature extends sensor life by sealing the sensor from oxygen in the air during storage. These sensors are warrantied for four years and are field replaceable.
A built-in dual-port manometer is included on the Fieldpiece CAT85K2 commercial combustion analyzer to measure gas pressures, a gas regulator operation, and even measure total external static pressure of a heating appliance.
The CAT85K2 also features live draft pressure measurements allowing the HVAC Professional to view the effects adjustments have on the draft pressure in real-time.
The patent pending HydroCycle™ Pump technology is included on Fieldpiece CAT85K2 flue probe that automatically separates and returns accumulated water to the flue.
The Fieldpiece CAT85K2 utilizes a convenient one-touch power on-button; pressing the power button initializes the short start-up period and unlocks the new SensorVault™ technology. The combustion testing starts automatically after the startup is complete.
The Fieldpiece combustion analyzer is intuitive, user-friendly, and makes data simple to scan. HVAC professionals will appreciate the clear view of all information on a single screen, the easy-to-navigate touchscreen display design, and the simple user interface.
The CAT85K2 combustion analyzer features a large, high-contrast 5.5” touchscreen display for viewing measurements. Save your customer data with dedicated fields for client information, and a live trend report is available with O2, CO, and CO2 readings, for more advanced diagnosis.
The Fieldpiece combustion analyzer is designed to handle the rigors of any job site with its thick over-molded construction, a long flexible hose/cord, and a padded hardline carrying case with multiple inserts for accessories. Plus, the magnetic back lets you work hands-free. The combustion analyzer comes with a rechargeable battery that lasts up to seven hours and enables charges in trucks between jobs and overnight.
The CAT85K2 is compatible with the Fieldpiece Job Link System App featuring its industry-leading 1000-foot wireless range. The Fieldpiece Job Link App allows technicians to view trends, draft pressure, and customer details seamlessly and conveniently.
A wireless printer (CATPR) is included with the Fieldpiece CAT85K2 for jobsites that require documentation printouts. If you would like the combustion analyzer without a printer, check out the Fieldpiece CAT85.

Features

  • Accurately measure O2, CO, CO2, draft pressure
  • Built-in dual manometer ports
  • HydroCycle Pump technology
  • Real-time live draft pressure
  • Large 5.5 touchscreen display with one-touch power on
  • SensorVault™ Technology
  • One-touch power button
  • Rechargeable Battery
  • In-use USB-C Charging
  • Field Replaceable Smart Sensors
  • Durable Hard Lined Case
  • Lower cost of ownership with four-year sensor warranty
  • Patent pending SensorVault™ Technology prolongs sensor life
  • Built-in manometer
  • HydroCycle™ Pump technology
  • Dual Manometer Ports
  • Large Intuitive Touchscreen
  • Powerful Trending
  • Inline Water Trap
  • Job Link® System App Compatible industry-leading 1000' wireless range
  • Wireless Printer (CATPR) Compatible (not included)

Top 5 Reasons to Own Fieldpiece CAT85 Combustion Analyzer:

  • SensorVault technology seals off sensors when not in use and extends sensor life
  • Sensors are warrantied for 4-years and are field replaceable
  • HydroCycle pump automatically returns water to the flue, eliminating the water trap
  • Built-in, dual-port manometer means one less tool to carry

Applications

  • Residential / Commercial HVAC/R

Fieldpiece CAT85 Specifications

Sensors
Temperature Type K rod thermocouple (fixed), < 30 seconds (T90)
Oxygen % Electrochemical (replaceable), < 30 seconds (T90), 30% Oxygen
Carbon Monoxide PPM Electrochemical (replaceable), < 90 seconds (T90), 10000 ppm Carbon Monoxide
Pressure (Probe) Piezoresistive pressure sensor, < 10 seconds (T90), 4.0 inWC will cause damage
Pressure (Ports) Silicon pressure sensors, < 10 seconds (T90), 11.6 psig (321 inWC) causes damage
Test Parameters
Stack Temperature 0.1°F (0.1°C): 32 to 752°F (0 to 400°C)
±2.5°F: 32 to 212°F
±(3.6°F or 1.5%rdg): 213 to 752°F
±1.4°C: 0 to 100°C
±(2.0°C or 1.5%rdg): 101 to 400°C
Oxygen O2 0 to 21 vol.%, 0.1 vol.%, ±0.3 vol.%
Carbon Monoxide CO 0 to 4000 ppm, 1 ppm, ±20 ppm [0 to 400 ppm], ±5%rdg [401 to 2000 ppm], ±10%rdg [2001 to 4000 ppm]
Draft Pressure 0 to ±0.8 inWC, 0.01 inWC, ±0.02 inWC
CO Air Free (Calculated) 0 to 4000 ppm, 1 ppm
CO2 (Calculated) 0 to CO2max vol.%, 0.1 vol.%
Excess Air (Calculated) 0 to 999%, ±0.1 vol.%
Efficiency (Calculated) 0 to 100%, 0.1%
qA (Calculated) 0 to 25%, 0.1%
Dew Point (Calculated) 32 to 212°F; 0 to 100°C, 0.1°F; 0.1°C
Primary Air Temp 0.1°F (0.1°C): 32 to 212°F (0 to 100°C)
±2.5°F: 32 to 212°F
±1.4°C: 0 to 100°C
Ambient CO 0 to 200 ppm, 1 ppm, ±20 ppm
Manometer 0.01 inWC: 0 to ±40 inWC
±0.2 inWC: 0 to ±20 inWC
±1%rdg: ±(20.1 to 40.0 inWC)
Fuel Pressures 0.01 inWC: 0 to 40 inWC
±0.2 inWC: 0 to 20 inWC
±1%rdg: 20.1 to 40.0 inWC
General Technical Data
Display Touchscreen TFT LCD (5.5 in diagonal)
Probe Size 10.7 in (272 mm) length, 0.32 in (8.0 mm) diameter
Accuracy Stated accuracies at 23°C ±5°C, <75% R.H.
Battery Type 3.7 VDC (nominal), 6400mAh, non-replaceable
Battery Life 7 hours typical (pump running 80% of the time)
Charge Time < 7 hours typical at 5V/2A DC power
Charging Port USB-C (Usable when connected to power.)
Memory 1000 jobs (approx.)
Warm Up Time 45 seconds (90 seconds near freezing)
Operating Environment 14°F to 104°F (-10°C to 40°C); < 75% RH (non-condensing)
Storage Temperature -4°F to 140°F (-20°C to 60°C); < 80% RH
Weight 39.5 oz (1120 g) with probe
Wireless Range 1000 feet (305 meters)
Fuel Types Natural Gas, Propane (LPG), Oil #2 (Light), Oil #6 (Heavy), Biofuel, Coal, Coal Town Gas, Coking Oven Gas, KOKS, Custom (x3)
Warranty 1 year (4 years sensors only)
Job Link® System Minimum BLE 4.0 devices running iOS 7.1 or Android™ Kitkat 4.4
Printer Fieldpiece Wireless Thermal Printer (model CATPR) (not included)
Certifications FCC ID: 2ALHRCATX5, IC: Industry Canada, IC: 22518-CATX5, Waste Electrical and Electronic Equipment

What's included with the Fieldpiece CAT85

  • CAT85 Combustion Analyzer (including probe)
  • 2 x Cones - RCONE3
  • 10 x Filters - RFC10
  • USB-C Charging Cable
  • Hard-Lined Carrying Case - ANC85
  • Operator's Manual
  • One-Year Device Warranty
  • Four-Year Sensor Warranty

Click on a category to view a selection of compatible accessories with the Fieldpiece CAT85 Combustion Analyzer HydroCycle Kit.

Fieldpiece BG36 Inspection Tool Bag BG36
Designed to carry every tool a technician needs for everyday call, the Fieldpiece BG36 is easy to carry and has an easy open pop top to protect your tools during rainy weather. The base of the bag is also weather-protected and keeps the bag standing upright during use.




Fieldpiece BG44 Tool Bag for HVAC/R Technician BG44
For the most common HVAC/R tools used in the field every day, BG44 has a place for everything. Fieldpiece BG44 Tool Bag for HVAC/R Technicians is the ultimate tool bag designed for HVAC/R professionals and general handymen. It features padded pockets for more sensitive equipment, a magnetic tray for quick and easy storage, straps for electrical tape and water bottles, and single strap carrying for convenience and speed. It also has a tough, elevated rack with slots to hold meters, screwdrivers, wrenches, etc. The elevated rack keeps everything in place and helps keep everything visible so nothing is ever lost.




Fieldpiece CATPR Wireless Thermal Printer CATPR
CATPR Wireless Thermal PrinterThe Fieldpiece CATPR is an easy-to-use, compact, wireless thermal printer compatible with the combustion analyzers CAT45 and CAT85.




More Fieldpiece Products