Optimize production yield for thermal processing with this programmable controller. Providing repeatable control and measurement performance, this controller features a 3.62 x 3.62" (92 x 92 mm) panel cut out, a current transformer, a 24 V transmitter power supply, and up to three freely selectable I/O modules.
Optimize production yield for thermal processing with this programmable controller. Providing repeatable control and measurement performance, this controller features a 3.62 x 3.62" (92 x 92 mm) panel cut out, a current transformer, a 24 V transmitter power supply, and up to three freely selectable I/O modules.
Maintain high standards with this programmable controller that provides efficient, consistent production quality.
Features
Applications
Reduce equipment costs and increase efficiency
Improve quality, reduce scrap and increase profits
Adaptable, scalable and digitized
World class certification
| Précision PV | <0.1% faible dérive thermique |
| Altitude | < 2000 mètres (< 6562 pi) |
| Panel size (DIN) | ¼ |
| PV Accuracy | <0.1% low thermal drift |
| Altitude | <6562' (2000 m) |
| Display Type | High Visibility LCD three color multifunction display 4.5, 5 digit PV, 2 starburst |
| Supply Voltage | 24 V DC/AC 85 to 264 V AC |
| Input Type | TC, PT100/PT1000 RTD, mV, mA, zirconia |
| Control Types | On/Off, PID, VP, carbon potential |
| Special Features | Dual input control, recipes, text messaging |
| SP Programmer | Up to 20 programmes of 8 segments or 10 programmes of 24 segments |
| Analogue IP/OP | 2 PV, 1 CT, 3 isolated DC OP |
| Digital Comms | BACNet, EIA-485, EtherNet/IP, Modbus RTU, Modbus TCP |
| Alarm Types | Hi, Lo, Dev, Sensor fault, Heater fail, Rate of Change, Event |
| IP Rating | Washdown: IP66, NEMA4x (indoor use) Standard: IP65, NEMA 12 |
| Temperature | Operating: 0 to 55°C (32 to 131°F) Storage: -20 to 70°C (-4 to 158°F) |
| Operating/Storage Humidity | 5 to 90% RH non-condensing |
| Atmosphere | Non-corrosive, non-explosive |
| Vibration and Shock | EN 61131-2 (5 to 11.9 Hz at 7 mm peak to peak displacement, 11.9 to 150 Hz at 2 g, 0.5 octave min.) EN 60068-2-6 Test FC, vibration. EN 60068-2-27 Test Ea and guidance, shock |
| Dimension | 3.62 x 3.62" (92 x 92 mm) |
| Weight | 14.81 oz (420 g) |
| Précision PV | <0.1% faible dérive thermique |
| Altitude | < 2000 mètres (< 6562 pi) |
| Panel size (DIN) | ¼ |
| PV Accuracy | <0.1% low thermal drift |
| Altitude | <6562' (2000 m) |
| Display Type | High Visibility LCD three color multifunction display 4.5, 5 digit PV, 2 starburst |
| Supply Voltage | 24 V DC/AC 85 to 264 V AC |
| Input Type | TC, PT100/PT1000 RTD, mV, mA, zirconia |
| Control Types | On/Off, PID, VP, carbon potential |
| Special Features | Dual input control, recipes, text messaging |
| SP Programmer | Up to 20 programmes of 8 segments or 10 programmes of 24 segments |
| Analogue IP/OP | 2 PV, 1 CT, 3 isolated DC OP |
| Digital Comms | BACNet, EIA-485, EtherNet/IP, Modbus RTU, Modbus TCP |
| Alarm Types | Hi, Lo, Dev, Sensor fault, Heater fail, Rate of Change, Event |
| IP Rating | Washdown: IP66, NEMA4x (indoor use) Standard: IP65, NEMA 12 |
| Temperature | Operating: 0 to 55°C (32 to 131°F) Storage: -20 to 70°C (-4 to 158°F) |
| Operating/Storage Humidity | 5 to 90% RH non-condensing |
| Atmosphere | Non-corrosive, non-explosive |
| Vibration and Shock | EN 61131-2 (5 to 11.9 Hz at 7 mm peak to peak displacement, 11.9 to 150 Hz at 2 g, 0.5 octave min.) EN 60068-2-6 Test FC, vibration. EN 60068-2-27 Test Ea and guidance, shock |
| Dimension | 3.62 x 3.62" (92 x 92 mm) |
| Weight | 14.81 oz (420 g) |