Dwyer MSXP-W11-PA Differential Pressure Transmitter Pro Unit, range 1

Model: MSXP-W11-PA

Dwyer MSXP-W11-PA Differential Pressure Transmitter Pro Unit, range 1

Model: MSXP-W11-PA

Simplifies the ordering process to deliver the desired configuration, which reduces product setup time with range 1 (100, 150, 160, 250 PA).

Simplifies the ordering process to deliver the desired configuration, which reduces product setup time with range 1 (100, 150, 160, 250 PA).

Sale Price $189.91 USD
Regular Price $207.55 USD
Availability 2 to 3 Weeks
Quantity

Dwyer MSXP-W11-PA Offers

The differential pressure transmitter pro unit has tamper resistant cover for added security and protection.

Features

  • Flip-lid provides easy access to the unit's wiring
  • Electronics shielded from installation eliminating accidental damage to the unit
  • UL94 V-0 and plenum ratings that add safety to a variety of applications needing to meet municipal and building code standards

Applications

  • High performance building applications for critical environments
  • Filter monitoring in air handler units
  • Building pressure in pharmaceutical/semiconductor clean rooms
  • Duct static pressure in commercial and specialized buildings
  • Air velocity/flow in VAV systems

Dwyer MSXP-W11-PA Specifications

Service Air and non-combustible, compatible gases
Wetted Materials Consult factory
Accuracy ±0.5% FSO for all ranges except unidirectional 0.5 in. @ ±1% FSO
Stability ±1% FSO/year
Temperature Limits -4 to 158°F (-20 to 70°C)
Pressure Limits Ranges 0 and 1: 3.6 psi max operation, 6 psi burst; Ranges 2 and 3: 6 psi max operation, 6 psi burst
Power Requirements 10-36 VDC (2-wire), 17-36 VDC or isolated 21.6-33 VAC (3-wire)
Output Signals 4-20 mA (2-wire); 0-10 V, 0-5 V (3-wire)
Response Time Instantaneous (default) or 3 s (selectable)
Zero and Span Adjustments Digital push-button
Loop Resistance Current output: 0-1250 Ω max; Voltage output: min. load resistance 1 kΩ
Current Consumption 21 mA max continuous
Electrical Connections 4-wire removable European style terminal block for 16 to 26 AWG
Electrical Entry ½" NPS thread. Cable gland included
Display (optional) 4 digit LCD
Process Connections ⅛", 3/16", ¼", 5 mm, and 6 mm ID flexible tubing
Enclosure Rating NEMA 4X (IP66); UL 2043 (Plenum); UL94 V-0
Mounting Orientation Pressure sensor measurement unaffected by orientation
Weight 8.0 oz (230 g)
Agency Approvals CE
Click here for complete specifications on the Dwyer MSXP-W11-PA

What's included with the Dwyer MSXP-W11-PA

  • Differential Pressure Transmitter Pro Unit
  • Liquid tight cable gland fitting for when there are liquids or moisture near the cable egress point
  • A tool less terminal block that allows for quick and easy wiring, reducing installation time

Dwyer MSXP-W11-PA Offers

The differential pressure transmitter pro unit has tamper resistant cover for added security and protection.

Features

  • Flip-lid provides easy access to the unit's wiring
  • Electronics shielded from installation eliminating accidental damage to the unit
  • UL94 V-0 and plenum ratings that add safety to a variety of applications needing to meet municipal and building code standards

Applications

  • High performance building applications for critical environments
  • Filter monitoring in air handler units
  • Building pressure in pharmaceutical/semiconductor clean rooms
  • Duct static pressure in commercial and specialized buildings
  • Air velocity/flow in VAV systems

Dwyer MSXP-W11-PA Specifications

Service Air and non-combustible, compatible gases
Wetted Materials Consult factory
Accuracy ±0.5% FSO for all ranges except unidirectional 0.5 in. @ ±1% FSO
Stability ±1% FSO/year
Temperature Limits -4 to 158°F (-20 to 70°C)
Pressure Limits Ranges 0 and 1: 3.6 psi max operation, 6 psi burst; Ranges 2 and 3: 6 psi max operation, 6 psi burst
Power Requirements 10-36 VDC (2-wire), 17-36 VDC or isolated 21.6-33 VAC (3-wire)
Output Signals 4-20 mA (2-wire); 0-10 V, 0-5 V (3-wire)
Response Time Instantaneous (default) or 3 s (selectable)
Zero and Span Adjustments Digital push-button
Loop Resistance Current output: 0-1250 Ω max; Voltage output: min. load resistance 1 kΩ
Current Consumption 21 mA max continuous
Electrical Connections 4-wire removable European style terminal block for 16 to 26 AWG
Electrical Entry ½" NPS thread. Cable gland included
Display (optional) 4 digit LCD
Process Connections ⅛", 3/16", ¼", 5 mm, and 6 mm ID flexible tubing
Enclosure Rating NEMA 4X (IP66); UL 2043 (Plenum); UL94 V-0
Mounting Orientation Pressure sensor measurement unaffected by orientation
Weight 8.0 oz (230 g)
Agency Approvals CE
Click here for complete specifications on the Dwyer MSXP-W11-PA

What's included with the Dwyer MSXP-W11-PA

  • Differential Pressure Transmitter Pro Unit
  • Liquid tight cable gland fitting for when there are liquids or moisture near the cable egress point
  • A tool less terminal block that allows for quick and easy wiring, reducing installation time

More Dwyer Products