Dwyer DM-2005-LCD Differential Pressure Transmitter (2"w.c.) with LCD

Model: DM-2005-LCD

Dwyer DM-2005-LCD Differential Pressure Transmitter (2"w.c.) with LCD

Model: DM-2005-LCD

Senses the pressure of air and compatible gases and sends a standard 4-20 mA output signal. Housing is specifically designed to mount in the same diameter cutout as a standard Magnehelic® gage.

Senses the pressure of air and compatible gases and sends a standard 4-20 mA output signal. Housing is specifically designed to mount in the same diameter cutout as a standard Magnehelic® gage.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

Dwyer DM-005 DigiMag Differential Pressure Transmitter, 2 inWC-

Dwyer DM-005 DigiMag Differential Pressure Transmitter, 2 inWC

Model: DM-005

Senses the pressure of air and compatible gases, this differential pressure transmitter features a pressure range of 2 inWC and has a 4 to 20 mA output. Fast and easy to set up, this transmitter is suitable for fan control, static pressures in ducts or buildings, room pressurization monitoring, and differential pressure across filters.


Dwyer DM-2005-LCD Offers

  • A wide range of models are available factory calibrated to specific ranges.
  • Pressure connections are inherent to the glass filled plastic molded housing making installation quick and easy.
  • Digital push-button zero and span simplify calibration over typical turn-potentiometers
  • An optional 3.5 digit LCD shows process and engineering units.
  • A single bush button allows field selection of 4 to 6 engineering units depending on range on LCD models.

Specifications

Service: Air and non-combustible, compatible gases.

Wetted Materials: Consult Factory.

Accuracy: ±1% F.S. at 70°F.

Stability: +1% F.S./yr.

Temperature Limits: 20 to 120°F (-6.67 to 48.9°C).

Pressure Limits: 10 psig (0.69 bar).

Thermal Effect: ±0.055% F.S./°F (0.099% F.S./°C).

Power Requirements: 10-35 VDC (2 wire).

Output Signal: 4 to 20 mA.

Zero and Span Adjustments: Digital push-button zero and span.

Loop Resistance: DC: 0-1250 ohms maximum.

Current Consumption: DC: 38 mA maximum.

Electrical Connections: Screw-type terminal block.

Display: 3.5 digit LCD, 0.7" height.

Process Connections: 1/8" I.D. tubing.

Mounting Orientation: Vertical.

Weight: 4.8 oz (136 g).

Features

  • Zero and span controls provide easy calibration checks and shorter installation time to get device running and monitoring
  • Quick response to pressure changes means no delay in signalling and alerting to critical situations
  • Easy to read LCD display provides immediate local alerts allowing corrective action to be taken quicker to eliminate the problem from becoming widespread
  • Same size as Magnehelic simplifies field upgrade to digital pressure gauge by reducing install steps
  • Tamper proof button configuration to prevent accidental changes to the settings

Applications

  • Filter monitoring
  • Fan pressure indication
  • Static pressures in ducts or buildings
  • Bi-direction ranges ideal for sensing fluctuating building pressure

Dwyer DM-2005-LCD Specifications

Service Air and non-combustible, compatible gases
Accuracy ±1% FS at 70°F
Stability ±1% FS/yr
Temperature Limits 20 to 120°F (-6.67 to 48.9°C)
Pressure Limits 10 psig (0.69 bar)
Thermal Effect ±0.055% F.S./°F (0.099% F.S./°C)
Power Requirements 10 to 35 VDC (2 wire)
Output Signal 4 to 20 mA
Zero and Span Adjustments Digital push-button zero and span
Loop Resistance DC: 0 to 1250 Ω maximum
Current Consumption DC: 38 mA maximum
Electrical Connections Screw-type terminal block
Display 3.5 digit LCD, 0.7" height
Process Connections ⅛" I.D. tubing
Mounting Orientation Vertical
Weight 4.8 oz (136 g)
Click here for complete specifications on the Dwyer DM-2005-LCD

What's included with the Dwyer DM-2005-LCD

  • Dwyer DM-2005-LCD Differential Pressure Transmitter (2"w.c.) with LCD

Dwyer DM-2005-LCD Offers

  • A wide range of models are available factory calibrated to specific ranges.
  • Pressure connections are inherent to the glass filled plastic molded housing making installation quick and easy.
  • Digital push-button zero and span simplify calibration over typical turn-potentiometers
  • An optional 3.5 digit LCD shows process and engineering units.
  • A single bush button allows field selection of 4 to 6 engineering units depending on range on LCD models.

Specifications

Service: Air and non-combustible, compatible gases.

Wetted Materials: Consult Factory.

Accuracy: ±1% F.S. at 70°F.

Stability: +1% F.S./yr.

Temperature Limits: 20 to 120°F (-6.67 to 48.9°C).

Pressure Limits: 10 psig (0.69 bar).

Thermal Effect: ±0.055% F.S./°F (0.099% F.S./°C).

Power Requirements: 10-35 VDC (2 wire).

Output Signal: 4 to 20 mA.

Zero and Span Adjustments: Digital push-button zero and span.

Loop Resistance: DC: 0-1250 ohms maximum.

Current Consumption: DC: 38 mA maximum.

Electrical Connections: Screw-type terminal block.

Display: 3.5 digit LCD, 0.7" height.

Process Connections: 1/8" I.D. tubing.

Mounting Orientation: Vertical.

Weight: 4.8 oz (136 g).

Features

  • Zero and span controls provide easy calibration checks and shorter installation time to get device running and monitoring
  • Quick response to pressure changes means no delay in signalling and alerting to critical situations
  • Easy to read LCD display provides immediate local alerts allowing corrective action to be taken quicker to eliminate the problem from becoming widespread
  • Same size as Magnehelic simplifies field upgrade to digital pressure gauge by reducing install steps
  • Tamper proof button configuration to prevent accidental changes to the settings

Applications

  • Filter monitoring
  • Fan pressure indication
  • Static pressures in ducts or buildings
  • Bi-direction ranges ideal for sensing fluctuating building pressure

Dwyer DM-2005-LCD Specifications

Service Air and non-combustible, compatible gases
Accuracy ±1% FS at 70°F
Stability ±1% FS/yr
Temperature Limits 20 to 120°F (-6.67 to 48.9°C)
Pressure Limits 10 psig (0.69 bar)
Thermal Effect ±0.055% F.S./°F (0.099% F.S./°C)
Power Requirements 10 to 35 VDC (2 wire)
Output Signal 4 to 20 mA
Zero and Span Adjustments Digital push-button zero and span
Loop Resistance DC: 0 to 1250 Ω maximum
Current Consumption DC: 38 mA maximum
Electrical Connections Screw-type terminal block
Display 3.5 digit LCD, 0.7" height
Process Connections ⅛" I.D. tubing
Mounting Orientation Vertical
Weight 4.8 oz (136 g)
Click here for complete specifications on the Dwyer DM-2005-LCD