Dwyer DM-007 DigiMag Differential Pressure Transmitter, 3 inWC

Model: DM-007

Dwyer DM-007 DigiMag Differential Pressure Transmitter, 3 inWC

Model: DM-007

Senses the pressure of air and compatible gases, this differential pressure transmitter features a pressure range of 3 inWC and has a 4 to 20 mA output. Fast and easy to set up, this transmitter is suitable for fan control, static pressures in ducts or buildings, room pressurization monitoring, and differential pressure across filters.

Senses the pressure of air and compatible gases, this differential pressure transmitter features a pressure range of 3 inWC and has a 4 to 20 mA output. Fast and easy to set up, this transmitter is suitable for fan control, static pressures in ducts or buildings, room pressurization monitoring, and differential pressure across filters.

Sale Price $158.71 USD
Regular Price $173.45 USD
Availability 1 to 2 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your Dwyer DM-007 DigiMag Differential Pressure Transmitter

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your Dwyer DM-007 DigiMag Differential Pressure Transmitter

Recommended Accessories


Dwyer DM-007 Offers

Specifically designed to mount in a standard Magnehelic® gauge cutout, this pressure transmitter features a polycarbonate molded housing with integral pressure connections, reducing installation time. In addition, the digital push-button zero and span simplify calibration over typical turn-potentiometers, and a single push-button allows field selection of multiple engineering units.

Features

  • Reduced installation time through zero and span controls that provides quick and easy calibration
  • Fast and easy setup and calibration with push-button zero and span controls
  • Immediate corrective action can be taken by local alerts via the easy-to-read LCD display
  • Reduces upgrade installation costs and simplifies field upgrade from a Magnehelic® gauge, as both use the same diameter cutout

Applications

  • Differential pressure across filters
  • Fan control
  • Static pressures in ducts or buildings
  • Room pressurization monitoring

Dwyer DM-007 Specifications

Service Air and non-combustible, compatible gases
Pressure Range 3 inWC
Accuracy ±1% FSO
Stability <±1%/year FSO
Limits Pressure: 6 psi maximum operation, 6 psi burst
Temperature: -4 to 158°F (-20 to 70°C)
Thermal Effect 0.02% FS/°F (0.036% FS/°C)
Output Signal 4 to 20 mA (2-wire)
Zero and Span Adjustments Push-button
Loop Resistance 0 to 1250 Ω maximum
Current Consumption 21 mA maximum
Connections Electrical: Screw-type terminals
Process: Male ports on side for ⅛", 316", ¼", 0.2" (5 mm), 0.23" (6 mm) ID flexible tubing
Power Requirements 10 to 35 V DC (2-wire)
Enclosure Rating NEMA 4X (IP66)
Mounting Orientation Not sensitive to position
Agency Approvals CE
Housing Material Polycarbonate
Dimensions Ø5 x 1.9" (Ø127 x 48.2 mm)
Weight 7.04 oz (200 g)
Click here for complete specifications on the Dwyer DM-007

What's included with the Dwyer DM-007

  • Dwyer DM-007 DigiMag Differential Pressure Transmitter, 3 inWC

Click on a category to view a selection of compatible accessories with the Dwyer DM-007 DigiMag Differential Pressure Transmitter, 3 inWC.

Dwyer DM-007 Offers

Specifically designed to mount in a standard Magnehelic® gauge cutout, this pressure transmitter features a polycarbonate molded housing with integral pressure connections, reducing installation time. In addition, the digital push-button zero and span simplify calibration over typical turn-potentiometers, and a single push-button allows field selection of multiple engineering units.

Features

  • Reduced installation time through zero and span controls that provides quick and easy calibration
  • Fast and easy setup and calibration with push-button zero and span controls
  • Immediate corrective action can be taken by local alerts via the easy-to-read LCD display
  • Reduces upgrade installation costs and simplifies field upgrade from a Magnehelic® gauge, as both use the same diameter cutout

Applications

  • Differential pressure across filters
  • Fan control
  • Static pressures in ducts or buildings
  • Room pressurization monitoring

Dwyer DM-007 Specifications

Service Air and non-combustible, compatible gases
Pressure Range 3 inWC
Accuracy ±1% FSO
Stability <±1%/year FSO
Limits Pressure: 6 psi maximum operation, 6 psi burst
Temperature: -4 to 158°F (-20 to 70°C)
Thermal Effect 0.02% FS/°F (0.036% FS/°C)
Output Signal 4 to 20 mA (2-wire)
Zero and Span Adjustments Push-button
Loop Resistance 0 to 1250 Ω maximum
Current Consumption 21 mA maximum
Connections Electrical: Screw-type terminals
Process: Male ports on side for ⅛", 316", ¼", 0.2" (5 mm), 0.23" (6 mm) ID flexible tubing
Power Requirements 10 to 35 V DC (2-wire)
Enclosure Rating NEMA 4X (IP66)
Mounting Orientation Not sensitive to position
Agency Approvals CE
Housing Material Polycarbonate
Dimensions Ø5 x 1.9" (Ø127 x 48.2 mm)