Dracal VCP-PTH450-CAL High-Precision USB Temperature, Humidity and Air Pressure Sensor with aluminum probe, -40 to 257°F, ±0.18°F

Model: VCP-PTH450-CAL | Order No: 605081

Dracal VCP-PTH450-CAL High-Precision USB Temperature, Humidity and Air Pressure Sensor with aluminum probe, -40 to 257°F, ±0.18°F

Model: VCP-PTH450-CAL | Order No: 605081

Ideal for environmental atmospheric pressure, temperature, and relative humidity acquisition, this sensor features an aluminum probe that protects against harsh conditions. Moreover, this calibratable ±0.18°F (±0.1°C) accuracy sensor works with the instrument in virtual COM port mode, and the USB port makes it usable in minutes.

Ideal for environmental atmospheric pressure, temperature, and relative humidity acquisition, this sensor features an aluminum probe that protects against harsh conditions. Moreover, this calibratable ±0.18°F (±0.1°C) accuracy sensor works with the instrument in virtual COM port mode, and the USB port makes it usable in minutes.

Your Price $335.99 USD
Availability 2 to 3 Weeks
Quantity

Dracal VCP-PTH450-CAL Offers

The PTH450 allows for the acquisition of temperature, relative humidity, and atmospheric pressure data in a harmonized manner, thanks to its advanced electronics. As a member of the PTH series, it stands out as the most robust, with its anodized aluminum-coated probe capable of withstanding temperatures of up to 257°F (125°C). The compact aluminum probe makes it easy to install in confined spaces, and the integrated filtration membrane provides additional protection against dust.

Furthermore, the probe cable is coated with silicone, making it highly resistant to heat, chemicals, UV radiation, and mechanical stress.

Like all Dracal measurement instruments, the PTH450 works with free software tools, making it an integral part of a DAQ (Data Acquisition) solution. For those looking to integrate the PTH450 into their system, command-line tools and VCP (Virtual COM Port) mode are two possible options. For those who prefer a graphical interface, DracalView is highly recommended.

Features

  • 3-point user calibration mechanism available for each of the three measurements
  • Freely switch between USB and VCP (COM protocol) mode
  • Two levels of particulate filters, improving probe life
  • Convenient remote temperature and humidity probe
  • It provides the user with additional data: dew point, humidex, heat index, and altitude
  • Long-term stability, with a drift of 0.03°C/year maximum
  • Installation time: Less than 10 minutes
  • Free DAQ software: Real-time data visualization and logging
  • Data integration: Command-line tools for direct data access and integration

Applications

  • OEM integration
  • Test chamber
  • GMP and GLP compliance verification
  • Site supervision
  • Greenhouse
  • Server rooms
  • Manufacturing
  • Pre-certification
  • Humidity control
  • Scientific research
  • Building automation
  • Engineering and R&D
  • Environmental chamber

Dracal VCP-PTH450-CAL Specifications

Temperature (probe)
Operating Range -40 to 257°F (-40 to 125°C)
Extended temperature: -49 to 266°F (-45 to 130°C)
Accuracy -40 to 68°F (-40 to 20°C):
Typ.: ±0.36°F (±0.2°C)
Maximum: ±0.54°F (±0.3°C)

68 to 140°F (20 to 60°C):
Typ.: ±0.18°F (±0.1°C)
Maximum: ±0.54°F (±0.3°C)

140 to 257°F (60 to 125°C):
Typ.: ±0.72°F (±0.4°C)
Maximum: ±1.08°F (±0.6°C)

-40 to 257°F (-40 to 125°C):
Typ.: ±0.72°F (±0.4°C)
Maximum: ±1.08°F (±0.6°C)
Resolution Typ.: 0.027°F (0.015°C)
Repeatability Typ.: 0.108°F (0.06°C)
Response Time t63%: 10 seconds
Factory Calibrated Yes, individually
Long-Term Drift Maximum: <0.054°F/year (<0.03°C/year)
Relative Humidity (probe)
Operating Range 0 to 100% RH, non-condensing
Accuracy 0 to 80% RH at 77°F (25°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

80 to 100% RH at 77°F (25°C):
Typ.: ±2% RH
Maximum: ±3% RH

0 to 80% RH from 50 to 122°F (10 to 50°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

0 to 100% RH from 32 to 176°F (0 to 80°C):
Typ.: ±2% RH
Maximum: ±3% RH
Resolution Typ.: 0.01% RH
Hysteresis At 77°F (25°C): 0.8% RH
Factory Calibration Yes, individually
Long-Term Drift -40 to 257°F (-40 to 125°C): Typ.<0.005% RH/year
Atmospheric Pressure
Sensor Location Inside the USB interface housing
Operating Range Temperature: -4 to 158°F (-20 to 70°C)
Pressure: 45 to 110 kPa, for full accuracy
Extended pressure: 1 to 120 kPa, linear range of ADC
Accuracy 70 to 110 kPa at 77°F (25°C): Typ.: ±0.15 kPa
70 to 110 kPa, from 50 to 104°F (10 to 40°C): Typ.: ±0.18 kPa
45 to 110 kPa from 32 to 122°F (0 to 50°C): Typ.: ±0.2 kPa
Overpressure Limit Pmax: 600 kPa
Altitude Resolution Approximately 3.94" (10 cm)
ADC Resolution 24 bits
Response Time 0.5 seconds
Sensor Location Inside the USB interface housing
Factory Calibration Yes, individually
Signal Noise Filter 1st order
Noise ±0.0012 kPa
Long-Term Drift ±0.1 kPa/year
Probe
Cable Material: Silicon
Length: 3' (1 m)
Filters Material:
Layer 1: Punctured Anodized Aluminum
Layer 2: PTFE membrane

Efficiency: 99.99% for particle size ≥200 nm
Housing and USB Cable
Operating Range Temperature: -4 to 158°F (-20 to 70°C)
Humidity: 10 to 90% RH, non-condensing
Material ABS
IP Rating 51
USB Cable Length 3' (1 m)
Power Supply
Voltage Powered through a USB port, 5 V
Current At 5V, 15 mA
Miscellaneous
Temperature Compensated Yes, by the manufacturer
Lifetime 5 years
Certification RoHS3
Click here for complete specifications on the Dracal VCP-PTH450-CAL

What's included with the Dracal VCP-PTH450-CAL

  • Sensor
  • USB Cable
  • Quick Installation Guide
  • Data Acquisition Solution to Download
  • Two-Year Warranty

Dracal VCP-PTH450-CAL Offers

The PTH450 allows for the acquisition of temperature, relative humidity, and atmospheric pressure data in a harmonized manner, thanks to its advanced electronics. As a member of the PTH series, it stands out as the most robust, with its anodized aluminum-coated probe capable of withstanding temperatures of up to 257°F (125°C). The compact aluminum probe makes it easy to install in confined spaces, and the integrated filtration membrane provides additional protection against dust.

Furthermore, the probe cable is coated with silicone, making it highly resistant to heat, chemicals, UV radiation, and mechanical stress.

Like all Dracal measurement instruments, the PTH450 works with free software tools, making it an integral part of a DAQ (Data Acquisition) solution. For those looking to integrate the PTH450 into their system, command-line tools and VCP (Virtual COM Port) mode are two possible options. For those who prefer a graphical interface, DracalView is highly recommended.

Features

  • 3-point user calibration mechanism available for each of the three measurements
  • Freely switch between USB and VCP (COM protocol) mode
  • Two levels of particulate filters, improving probe life
  • Convenient remote temperature and humidity probe
  • It provides the user with additional data: dew point, humidex, heat index, and altitude
  • Long-term stability, with a drift of 0.03°C/year maximum
  • Installation time: Less than 10 minutes
  • Free DAQ software: Real-time data visualization and logging
  • Data integration: Command-line tools for direct data access and integration

Applications

  • OEM integration
  • Test chamber
  • GMP and GLP compliance verification
  • Site supervision
  • Greenhouse
  • Server rooms
  • Manufacturing
  • Pre-certification
  • Humidity control
  • Scientific research
  • Building automation
  • Engineering and R&D
  • Environmental chamber

Dracal VCP-PTH450-CAL Specifications

Temperature (probe)
Operating Range -40 to 257°F (-40 to 125°C)
Extended temperature: -49 to 266°F (-45 to 130°C)
Accuracy -40 to 68°F (-40 to 20°C):
Typ.: ±0.36°F (±0.2°C)
Maximum: ±0.54°F (±0.3°C)

68 to 140°F (20 to 60°C):
Typ.: ±0.18°F (±0.1°C)
Maximum: ±0.54°F (±0.3°C)

140 to 257°F (60 to 125°C):
Typ.: ±0.72°F (±0.4°C)
Maximum: ±1.08°F (±0.6°C)

-40 to 257°F (-40 to 125°C):
Typ.: ±0.72°F (±0.4°C)
Maximum: ±1.08°F (±0.6°C)
Resolution Typ.: 0.027°F (0.015°C)
Repeatability Typ.: 0.108°F (0.06°C)
Response Time t63%: 10 seconds
Factory Calibrated Yes, individually
Long-Term Drift Maximum: <0.054°F/year (<0.03°C/year)
Relative Humidity (probe)
Operating Range 0 to 100% RH, non-condensing
Accuracy 0 to 80% RH at 77°F (25°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

80 to 100% RH at 77°F (25°C):
Typ.: ±2% RH
Maximum: ±3% RH

0 to 80% RH from 50 to 122°F (10 to 50°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

0 to 100% RH from 32 to 176°F (0 to 80°C):
Typ.: ±2% RH
Maximum: ±3% RH
Resolution Typ.: 0.01% RH
Hysteresis At 77°F (25°C): 0.8% RH
Factory Calibration Yes, individually
Long-Term Drift -40 to 257°F (-40 to 125°C): Typ.<0.005% RH/year
Atmospheric Pressure
Sensor Location Inside the USB interface housing
Operating Range Temperature: -4 to 158°F (-20 to 70°C)
Pressure: 45 to 110 kPa, for full accuracy
Extended pressure: 1 to 120 kPa, linear range of ADC
Accuracy 70 to 110 kPa at 77°F (25°C): Typ.: ±0.15 kPa
70 to 110 kPa, from 50 to 104°F (10 to 40°C): Typ.: ±0.18 kPa
45 to 110 kPa from 32 to 122°F (0 to 50°C): Typ.: ±0.2 kPa
Overpressure Limit Pmax: 600 kPa
Altitude Resolution Approximately 3.94" (10 cm)
ADC Resolution 24 bits
Response Time 0.5 seconds
Sensor Location Inside the USB interface housing
Factory Calibration Yes, individually
Signal Noise Filter 1st order
Noise ±0.0012 kPa
Long-Term Drift ±0.1 kPa/year
Probe
Cable Material: Silicon
Length: 3' (1 m)
Filters Material:
Layer 1: Punctured Anodized Aluminum
Layer 2: PTFE membrane

Efficiency: 99.99% for particle size ≥200 nm
Housing and USB Cable
Operating Range Temperature: -4 to 158°F (-20 to 70°C)
Humidity: 10 to 90% RH, non-condensing
Material ABS
IP Rating 51
USB Cable Length 3' (1 m)
Power Supply
Voltage Powered through a USB port, 5 V
Current At 5V, 15 mA
Miscellaneous
Temperature Compensated Yes, by the manufacturer
Lifetime 5 years
Certification RoHS3
Click here for complete specifications on the Dracal VCP-PTH450-CAL

What's included with the Dracal VCP-PTH450-CAL

  • Sensor
  • USB Cable
  • Quick Installation Guide
  • Data Acquisition Solution to Download
  • Two-Year Warranty