Dracal VCP-PTH420-CAL Precision USB Atmospheric Pressure, Temperature and Relative Humidity Sensor with 2-layer filter, -40 to 158°F, ±0.18°F

Model: VCP-PTH420-CAL | Order No: 605080

Dracal VCP-PTH420-CAL Precision USB Atmospheric Pressure, Temperature and Relative Humidity Sensor with 2-layer filter, -40 to 158°F, ±0.18°F

Model: VCP-PTH420-CAL | Order No: 605080

Ideal for environmental atmospheric pressure, temperature, and relative humidity acquisition, this sensor features a 2-layer filter that protects against harsh conditions. Moreover, this calibratable ±0.18°F (±0.1°C) accuracy sensor works with the instrument in virtual COM port mode, and the USB port makes it usable in minutes.

Ideal for environmental atmospheric pressure, temperature, and relative humidity acquisition, this sensor features a 2-layer filter that protects against harsh conditions. Moreover, this calibratable ±0.18°F (±0.1°C) accuracy sensor works with the instrument in virtual COM port mode, and the USB port makes it usable in minutes.

Your Price $304.99 USD
Availability 2 to 3 Weeks
Quantity

Dracal VCP-PTH420-CAL Offers

This instrument, a member of the PTH series, is specially designed for environmental data acquisition where improved precision is required. The units are directly interchangeable thanks to a factory-calibrated, linear, and compensated digital sensor. The PTH420 offers a wide measurement range, capable of operating in environments ranging from -40 to 125°F (-40 to 70°C) for temperature and from 0 to 100% RH for relative humidity, with a long-term drift of less than 0.054°F/year (0.03°C/year) for temperature and 0.25% RH/year for relative humidity, ensuring reliable long-term measurements. With its digital sensor and USB connectivity, the PTH420 can capture and record very small temperature and humidity variations, allowing for detailed data analysis that is always harmonized. Furthermore, with its ability to measure atmospheric pressure with an accuracy of ±0.15 kPa, the PTH420 is a valuable tool for applications requiring precise knowledge of atmospheric pressure.

Like all Dracal measurement instruments, the PTH420 is compatible with free software tools, making it an essential component of a DAQ solution. For those who wish to integrate the PTH420 into their system, there are two options available: command line tools and VCP mode. If you prefer a graphical interface, DracalView is the appropriate choice.

Features

  • 3-point user calibration mechanism available for each of the three measurements
  • Freely switch between USB and VCP (COM protocol) mode
  • Two levels of particulate filters, improving probe life
  • Convenient remote temperature and humidity probe
  • It provides the user with additional data: dew point, humidex, heat index, and altitude
  • Long-term stability, with a drift of 0.03°C/year maximum
  • Installation time: Less than 10 minutes
  • Free DAQ software: Real-time data visualization and logging
  • Data integration: Command-line tools for direct data access and integration

Applications

  • OEM integration
  • Weather station
  • GMP and GLP compliance verification
  • Navigation conditions
  • Greenhouse
  • Server rooms
  • Manufacturing
  • Pre-certification
  • Humidity control
  • Scientific research
  • Building automation
  • Engineering and R&D
  • Environmental chamber

Dracal VCP-PTH420-CAL Specifications

Temperature (probe)
Operating range -40 to 158°F (-40 to 70°C)
Extended temperature: -45 to 80°C
Accuracy -40 to 68°F (-40 to 20°C):
Typ. ±0.36°F (±0.2°C)
Maximum ±0.54°F (±0.3°C)

68 to 140°F (20 to 60°C):
Typ.: ±0.18°F (±0.1°C)
Maximum: ±0.54°F (±0.3°C)

140 to 158°F (60 to 70°C):
Typ.: ±0.27°F (±0.15°C)
Maximum: ±0.54°F (±0.3°C)

-40 to 158°F (-40 to 70°C):
Typ.: ±0.36°F (±0.2°C)
Maximum: ±0.54°F (±0.3°C)
Resolution Typ.: 0.027°F (0.015°C)
Repeatability Typ.: 0.108°F (0.06°C)
Response Time t63%: 10s
Factory Calibrated Yes, individually
Long-Term Drift Maximum: <0.054°F/year (<0.03°C/year)
Relative Humidity (probe)
Operating Range 0 to 100% RH, non-condensing
Accuracy 0 to 80% RH at 77°F (25°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

80 to 100% RH at 77°F (25°C):
Typ.: ±2% RH
Maximum: ±3% RH

0 to 80% RH from 50 to 122°F (10 to 50°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

0 to 100% RH from 32 to 158°F (0 to 70°C):
Typ.: ±2% RH
Maximum: ±3% RH
Resolution Typ.: 0.01% RH
Hysteresis At 77°F (25°C): 0.8% RH
Factory Calibrated Yes, individually
Long-Term Drift Typ. from -40 to 158°F ( -40 to 70°C): <0.25% RH/year
Atmospheric Pressure
Sensor Location Inside the USB interface housing
Operating Range Temperature: -4 to 158°F (-20 to 70°C)
Pressure: 45 to 110 kPa, for full accuracy
Extended pressure: 1 to 120 kPa, linear range of ADC
Accuracy 70 to 110 kPa at 77°F (25°C): Typ.: ±0.15 kPa

70 to 110 kPa from 50 to 104°F (10 to 40°C): Typ.: ±0.18 kPa

45 to 110 kPa from 32 to 122°F (0 to 50°C): Typ.: ±0.2 kPa
Overpressure Limit Pmax: 600 kPa
Altitude Resolution Approximately 3.94" (10 cm)
ADC Resolution 24 bits
Response Time 0.5 seconds
Factory Calibration Yes, individually
Noise ±0.0012 kPa
Long-Term Drift ±0.1 kPa/year
Probe
Cable Material: PVC
Length: 3' (1 m)
Filters Material:
Layer 1: Polyethylene terephthalate (PET) mesh
Layer 2: PTFE membrane

Efficiency: 99.99% for particle size ≥200 nm
Housing and USB cable
Operating Range Temperature : -4 to 158°F (-20 to 70°C)
Humidity: 10 to 90% RH, non-condensing
Material ABS
IP Rating 51
USB Cable Length 3' (1 m)
General Specifications
Voltage Powered through a USB port, 5 V
Current At 5V, 15 mA
Temperature Compensated Yes, by the manufacturer
Lifetime 5 years
Certification RoHS3
Click here for complete specifications on the Dracal VCP-PTH420-CAL

What's included with the Dracal VCP-PTH420-CAL

  • Sensor
  • USB Cable
  • Quick Installation Guide
  • Data Acquisition Solution to Download
  • Two-Year Warranty

Dracal VCP-PTH420-CAL Offers

This instrument, a member of the PTH series, is specially designed for environmental data acquisition where improved precision is required. The units are directly interchangeable thanks to a factory-calibrated, linear, and compensated digital sensor. The PTH420 offers a wide measurement range, capable of operating in environments ranging from -40 to 125°F (-40 to 70°C) for temperature and from 0 to 100% RH for relative humidity, with a long-term drift of less than 0.054°F/year (0.03°C/year) for temperature and 0.25% RH/year for relative humidity, ensuring reliable long-term measurements. With its digital sensor and USB connectivity, the PTH420 can capture and record very small temperature and humidity variations, allowing for detailed data analysis that is always harmonized. Furthermore, with its ability to measure atmospheric pressure with an accuracy of ±0.15 kPa, the PTH420 is a valuable tool for applications requiring precise knowledge of atmospheric pressure.

Like all Dracal measurement instruments, the PTH420 is compatible with free software tools, making it an essential component of a DAQ solution. For those who wish to integrate the PTH420 into their system, there are two options available: command line tools and VCP mode. If you prefer a graphical interface, DracalView is the appropriate choice.

Features

  • 3-point user calibration mechanism available for each of the three measurements
  • Freely switch between USB and VCP (COM protocol) mode
  • Two levels of particulate filters, improving probe life
  • Convenient remote temperature and humidity probe
  • It provides the user with additional data: dew point, humidex, heat index, and altitude
  • Long-term stability, with a drift of 0.03°C/year maximum
  • Installation time: Less than 10 minutes
  • Free DAQ software: Real-time data visualization and logging
  • Data integration: Command-line tools for direct data access and integration

Applications

  • OEM integration
  • Weather station
  • GMP and GLP compliance verification
  • Navigation conditions
  • Greenhouse
  • Server rooms
  • Manufacturing
  • Pre-certification
  • Humidity control
  • Scientific research
  • Building automation
  • Engineering and R&D
  • Environmental chamber

Dracal VCP-PTH420-CAL Specifications

Temperature (probe)
Operating range -40 to 158°F (-40 to 70°C)
Extended temperature: -45 to 80°C
Accuracy -40 to 68°F (-40 to 20°C):
Typ. ±0.36°F (±0.2°C)
Maximum ±0.54°F (±0.3°C)

68 to 140°F (20 to 60°C):
Typ.: ±0.18°F (±0.1°C)
Maximum: ±0.54°F (±0.3°C)

140 to 158°F (60 to 70°C):
Typ.: ±0.27°F (±0.15°C)
Maximum: ±0.54°F (±0.3°C)

-40 to 158°F (-40 to 70°C):
Typ.: ±0.36°F (±0.2°C)
Maximum: ±0.54°F (±0.3°C)
Resolution Typ.: 0.027°F (0.015°C)
Repeatability Typ.: 0.108°F (0.06°C)
Response Time t63%: 10s
Factory Calibrated Yes, individually
Long-Term Drift Maximum: <0.054°F/year (<0.03°C/year)
Relative Humidity (probe)
Operating Range 0 to 100% RH, non-condensing
Accuracy 0 to 80% RH at 77°F (25°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

80 to 100% RH at 77°F (25°C):
Typ.: ±2% RH
Maximum: ±3% RH

0 to 80% RH from 50 to 122°F (10 to 50°C):
Typ.: ±1.5% RH
Maximum: ±2% RH

0 to 100% RH from 32 to 158°F (0 to 70°C):
Typ.: ±2% RH
Maximum: ±3% RH
Resolution Typ.: 0.01% RH
Hysteresis At 77°F (25°C): 0.8% RH
Factory Calibrated Yes, individually
Long-Term Drift Typ. from -40 to 158°F ( -40 to 70°C): <0.25% RH/year
Atmospheric Pressure
Sensor Location Inside the USB interface housing
Operating Range Temperature: -4 to 158°F (-20 to 70°C)
Pressure: 45 to 110 kPa, for full accuracy
Extended pressure: 1 to 120 kPa, linear range of ADC
Accuracy 70 to 110 kPa at 77°F (25°C): Typ.: ±0.15 kPa

70 to 110 kPa from 50 to 104°F (10 to 40°C): Typ.: ±0.18 kPa

45 to 110 kPa from 32 to 122°F (0 to 50°C): Typ.: ±0.2 kPa
Overpressure Limit Pmax: 600 kPa
Altitude Resolution Approximately 3.94" (10 cm)
ADC Resolution 24 bits
Response Time 0.5 seconds
Factory Calibration Yes, individually
Noise ±0.0012 kPa
Long-Term Drift ±0.1 kPa/year
Probe
Cable Material: PVC
Length: 3' (1 m)
Filters Material:
Layer 1: Polyethylene terephthalate (PET) mesh
Layer 2: PTFE membrane

Efficiency: 99.99% for particle size ≥200 nm
Housing and USB cable
Operating Range Temperature : -4 to 158°F (-20 to 70°C)
Humidity: 10 to 90% RH, non-condensing
Material ABS
IP Rating 51
USB Cable Length 3' (1 m)
General Specifications
Voltage Powered through a USB port, 5 V
Current At 5V, 15 mA
Temperature Compensated Yes, by the manufacturer
Lifetime 5 years
Certification RoHS3
Click here for complete specifications on the Dracal VCP-PTH420-CAL

What's included with the Dracal VCP-PTH420-CAL

  • Sensor
  • USB Cable
  • Quick Installation Guide
  • Data Acquisition Solution to Download
  • Two-Year Warranty