Dent PowerScout™ FLEX 48 Series Multi-Circuit Power Submeter with display, enclosure, CTEP certified

Model: PS48FX-C-D-N-C

Dent PowerScout™ FLEX 48 Series Multi-Circuit Power Submeter with display, enclosure, CTEP certified

Model: PS48FX-C-D-N-C

Monitoring 48 individual circuits on any combination of single-phase and three-phase systems, this multi-circuit power submeter delivers revenue-grade Class 0.2 accuracy for tenant billing and facility energy tracking. Its four-line display reports live values at the panel, while a tamper-evident seal switch supports CTEP certified commercial weights and measures installations.

Monitoring 48 individual circuits on any combination of single-phase and three-phase systems, this multi-circuit power submeter delivers revenue-grade Class 0.2 accuracy for tenant billing and facility energy tracking. Its four-line display reports live values at the panel, while a tamper-evident seal switch supports CTEP certified commercial weights and measures installations.

Sale Price $2784.45 USD
Regular Price $2931.00 USD
Availability 2 to 3 Weeks
Quantity

Dent PS48FX-C-D-N-C Offers

PowerScout™ FLEX 48 is Dent's multi-circuit submeter engineered for faster setup, smarter commissioning, and clearer system insight. Replacing the PowerScout™ HD, FLEX simplifies installation, enhances configuration workflows, and delivers accurate, real-time data across a wide range of electrical environments. Whether deploying in the field or overseeing large-scale facilities, FLEX provides the flexibility, performance, and control today's teams need.

FLEXPoint™ configuration software provides a modern interface, guided workflows that reduce setup time, and smarter defaults that eliminate guesswork. FLEXPoint™ GO adds a browser-based web server that configures the meter from any browser with no installation required, suiting quick changes, onsite validation, and field troubleshooting. Virtual Meters assign any CT channel to any load in any combination, so single-phase, split-phase, or three-phase groupings can be created and labelled to match how the site is organized, and those labels follow through to the display, the register data, and the cloud.

Features

  • 48 channels: multi-circuit submeter monitors voltage, current, power, energy, and many other electrical parameters on any combination of single and/or three-phase systems
  • Dual voltage inputs allow the meter to be used on two systems simultaneously
  • Line-powered: 90 to 600 V phase-to-phase power supply
  • Revenue-grade accuracy: meets ANSI C12.1-2024 Class 0.2, dependent on CT selection
  • Flexible hardware options: supplied in a UL 94-V0 rated enclosure (circuit board on a mounting plate also available)
  • High-voltage protection: TouchSaf™ high-voltage cover offers an additional level of protection
  • Dual-protocol communications: uses either BACnet or Modbus protocol and features 2 digital pulse input ports, with both serial and Ethernet on all models
  • Floating point data format: IEEE-754 data format allows for bidirectional monitoring and eliminates scaling factors
  • Universal CT compatibility: mix and match a full range of CTs including solid core, split core or RoCoil Rogowski coils, with revenue-grade options available
  • Real-time display: integrated LCD shows meter status, configuration, and live metered values
  • PhaseChek™ verification: confirms correct CT orientation and phase matching, reducing installation errors
  • Certified and compliant: UL Listed enclosure and CE marked
  • CTEP certified with a tamper-evident seal switch for commercial weights and measures applications

Applications

  • Hospitals
  • Data centers
  • Tenant submetering
  • Bi-directional metering
  • Commercial and industrial monitoring
  • HVAC/R, pumps, motors, and equipment loads

Dent PS48FX-C-D-N-C Specifications

Key Specifications
Service Type Single phase, split phase, three phase-four wire (WYE), three phase-three wire (Delta)
Current Channels 48 channels, 0.525 V AC maximum, 333.3 mV CTs, 0 to 4000 A depending on CT
Voltage Channels 90 to 346 V AC line-to-neutral, 600 V line-to-line, CAT III. Two voltage reference inputs
Accuracy 0.2%, ANSI C12.1-2024 Class 0.2
Measurement Type True RMS using high-speed digital signal processing with continuous sampling
Display 4-line display, tri-color backlight (PhaseChek™)
Electrical
Power From L1 phase to L2 phase. 90 to 600 V AC RMS CAT III, 50/60 Hz, 500 mA AC maximum. Use of the 12 volt auxiliary output requires 100 V AC minimum input voltage
AC Protection 0.5 A fuse, 200 kA interrupt capacity
Power Out Unregulated 12 V DC output, 200 mA, self-resetting fuse
Maximum Current Input 150% of current transducer rating for mV CTs to maintain accuracy. Measure up to 4000 A with RoCoil CTs
Line Frequency 50/60 Hz, 45 to 65 Hz measurable range. Measurement taken L1-N
Waveform Sampling Continuous 7.2 kHz, no blind cycles
Parameter Update Rate 1 second
Measurements Volts, amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, import (delivered) kWh, export (received) kWh, net kWh, import (delivered) kVAh, export (received) kVAh, net kVAh, import (delivered) kVARh, export (received) kVARh, net kVARh, THD, theta, and frequency. All parameters for each phase and virtual meter
Resolution Values in IEEE-754 single precision floating point format, 32 bit
Alarm Output Under voltage, open collector, 30 V DC maximum
Pulse Inputs Two inputs. 3.3 V sourcing voltage, current limited, to customer dry contact pulse output. Maximum pulse rate 10 Hz with 50 milliseconds minimum transition time
Communications
Hardware RS-485, Ethernet, and USB for configuration only
Supported Protocols Modbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP, DENTCloud (optional)
Maximum Communication Length 1200 meters with a data range of 100K bits/second or less
Communication Rate Modbus: 9600, 19200, 38400, 57600, 76800, 115200 baud. BACnet: 9600, 19200, 38400, 76800 baud
Data Bits 8
Parity None, even, odd
Stop Bit 2, 1
Termination None provided
Mechanical
Wire Connections 12 to 28 AWG, 600 V AC. Voltage connection must be #14 AWG or larger and rated 600 V AC
Mounting Panel mount enclosure
High Voltage Cover IP30. Available with PS48 enclosure and plate models
Operating Temperature -4 to 140°F (-20 to 60°C). At -20°C the display could be illegible and meter voltage must exceed 100 V AC to power the meter
Humidity 5% to 95% non-condensing
Enclosure ABS plastic, 94-V0 flammability rating. Connections: 1" EMT conduit
Enclosure Dimensions 13.3 x 9.8 x 3.1" (33.7 x 25.1 x 8.0 cm)
Circuit Board Dimensions 8.5 x 8.5 x 2.5" (21.6 x 21.6 x 6.4 cm)
Seal Switch Tamper-evident seal switch fitted on commercial weights and measures models
Software
Operating System Windows 11, Windows 10. ARM processors are not supported
Communications USB and Ethernet standard. One USB port required on the PC
Security Two levels of PIN protection, read/write or read-only
Certifications
UL Listed (E186827) Applies to the indoor enclosure version. Conforms to UL Std 61010-1 3rd Edition. Certified to CSA Std C22.2 No. 61010-1 3rd Edition
CE LVD (EN61010-1), EMC (EN61326-1), RoHS 3 (IEC 63000:2018)
ANSI C12.1 Class 0.2 NIST traceable calibration
Revenue Certification CTEP certified for commercial weights and measures applications
Click here for complete specifications on the Dent PS48FX-C-D-N-C

What's included with the Dent PS48FX-C-D-N-C

  • Multi-Circuit Power Submeter
  • Certificate of Calibration
  • LCD User Interface
  • Tamper-Evident Seals
  • Pluggable Terminal Connectors
  • USB-C Configuration Cable
  • FLEXPoint Software Access Information
  • Product Documentation
  • Five-Year Warranty

Dent PS48FX-C-D-N-C Offers

PowerScout™ FLEX 48 is Dent's multi-circuit submeter engineered for faster setup, smarter commissioning, and clearer system insight. Replacing the PowerScout™ HD, FLEX simplifies installation, enhances configuration workflows, and delivers accurate, real-time data across a wide range of electrical environments. Whether deploying in the field or overseeing large-scale facilities, FLEX provides the flexibility, performance, and control today's teams need.

FLEXPoint™ configuration software provides a modern interface, guided workflows that reduce setup time, and smarter defaults that eliminate guesswork. FLEXPoint™ GO adds a browser-based web server that configures the meter from any browser with no installation required, suiting quick changes, onsite validation, and field troubleshooting. Virtual Meters assign any CT channel to any load in any combination, so single-phase, split-phase, or three-phase groupings can be created and labelled to match how the site is organized, and those labels follow through to the display, the register data, and the cloud.

Features

  • 48 channels: multi-circuit submeter monitors voltage, current, power, energy, and many other electrical parameters on any combination of single and/or three-phase systems
  • Dual voltage inputs allow the meter to be used on two systems simultaneously
  • Line-powered: 90 to 600 V phase-to-phase power supply
  • Revenue-grade accuracy: meets ANSI C12.1-2024 Class 0.2, dependent on CT selection
  • Flexible hardware options: supplied in a UL 94-V0 rated enclosure (circuit board on a mounting plate also available)
  • High-voltage protection: TouchSaf™ high-voltage cover offers an additional level of protection
  • Dual-protocol communications: uses either BACnet or Modbus protocol and features 2 digital pulse input ports, with both serial and Ethernet on all models
  • Floating point data format: IEEE-754 data format allows for bidirectional monitoring and eliminates scaling factors
  • Universal CT compatibility: mix and match a full range of CTs including solid core, split core or RoCoil Rogowski coils, with revenue-grade options available
  • Real-time display: integrated LCD shows meter status, configuration, and live metered values
  • PhaseChek™ verification: confirms correct CT orientation and phase matching, reducing installation errors
  • Certified and compliant: UL Listed enclosure and CE marked
  • CTEP certified with a tamper-evident seal switch for commercial weights and measures applications

Applications

  • Hospitals
  • Data centers
  • Tenant submetering
  • Bi-directional metering
  • Commercial and industrial monitoring
  • HVAC/R, pumps, motors, and equipment loads

Dent PS48FX-C-D-N-C Specifications

Key Specifications
Service Type Single phase, split phase, three phase-four wire (WYE), three phase-three wire (Delta)
Current Channels 48 channels, 0.525 V AC maximum, 333.3 mV CTs, 0 to 4000 A depending on CT
Voltage Channels 90 to 346 V AC line-to-neutral, 600 V line-to-line, CAT III. Two voltage reference inputs
Accuracy 0.2%, ANSI C12.1-2024 Class 0.2
Measurement Type True RMS using high-speed digital signal processing with continuous sampling
Display 4-line display, tri-color backlight (PhaseChek™)
Electrical
Power From L1 phase to L2 phase. 90 to 600 V AC RMS CAT III, 50/60 Hz, 500 mA AC maximum. Use of the 12 volt auxiliary output requires 100 V AC minimum input voltage
AC Protection 0.5 A fuse, 200 kA interrupt capacity
Power Out Unregulated 12 V DC output, 200 mA, self-resetting fuse
Maximum Current Input 150% of current transducer rating for mV CTs to maintain accuracy. Measure up to 4000 A with RoCoil CTs
Line Frequency 50/60 Hz, 45 to 65 Hz measurable range. Measurement taken L1-N
Waveform Sampling Continuous 7.2 kHz, no blind cycles
Parameter Update Rate 1 second
Measurements Volts, amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, import (delivered) kWh, export (received) kWh, net kWh, import (delivered) kVAh, export (received) kVAh, net kVAh, import (delivered) kVARh, export (received) kVARh, net kVARh, THD, theta, and frequency. All parameters for each phase and virtual meter
Resolution Values in IEEE-754 single precision floating point format, 32 bit
Alarm Output Under voltage, open collector, 30 V DC maximum
Pulse Inputs Two inputs. 3.3 V sourcing voltage, current limited, to customer dry contact pulse output. Maximum pulse rate 10 Hz with 50 milliseconds minimum transition time
Communications
Hardware RS-485, Ethernet, and USB for configuration only
Supported Protocols Modbus RTU, BACnet MS/TP, Modbus TCP or BACnet IP, DENTCloud (optional)
Maximum Communication Length 1200 meters with a data range of 100K bits/second or less
Communication Rate Modbus: 9600, 19200, 38400, 57600, 76800, 115200 baud. BACnet: 9600, 19200, 38400, 76800 baud
Data Bits 8
Parity None, even, odd
Stop Bit 2, 1
Termination None provided
Mechanical
Wire Connections 12 to 28 AWG, 600 V AC. Voltage connection must be #14 AWG or larger and rated 600 V AC
Mounting Panel mount enclosure
High Voltage Cover IP30. Available with PS48 enclosure and plate models
Operating Temperature -4 to 140°F (-20 to 60°C). At -20°C the display could be illegible and meter voltage must exceed 100 V AC to power the meter
Humidity 5% to 95% non-condensing
Enclosure ABS plastic, 94-V0 flammability rating. Connections: 1" EMT conduit
Enclosure Dimensions 13.3 x 9.8 x 3.1" (33.7 x 25.1 x 8.0 cm)
Circuit Board Dimensions 8.5 x 8.5 x 2.5" (21.6 x 21.6 x 6.4 cm)
Seal Switch Tamper-evident seal switch fitted on commercial weights and measures models
Software
Operating System Windows 11, Windows 10. ARM processors are not supported
Communications USB and Ethernet standard. One USB port required on the PC
Security Two levels of PIN protection, read/write or read-only
Certifications
UL Listed (E186827) Applies to the indoor enclosure version. Conforms to UL Std 61010-1 3rd Edition. Certified to CSA Std C22.2 No. 61010-1 3rd Edition
CE LVD (EN61010-1), EMC (EN61326-1), RoHS 3 (IEC 63000:2018)
ANSI C12.1 Class 0.2 NIST traceable calibration
Revenue Certification CTEP certified for commercial weights and measures applications
Click here for complete specifications on the Dent PS48FX-C-D-N-C

What's included with the Dent PS48FX-C-D-N-C

  • Multi-Circuit Power Submeter
  • Certificate of Calibration
  • LCD User Interface
  • Tamper-Evident Seals
  • Pluggable Terminal Connectors
  • USB-C Configuration Cable
  • FLEXPoint Software Access Information
  • Product Documentation
  • Five-Year Warranty

More Dent Products