Measuring tenant loads and building circuits to billing-level accuracy, this revenue grade split-core current transformer opens around a conductor that is already in place, so no circuit has to be disconnected to fit it. The 333 mV output pairs with Dent PowerScout FLEX and HD meters, and rated accuracy holds to ±0.3% for energy and demand submetering. Features a window size of 1.25" and offers a 400A amp rating.
Measuring tenant loads and building circuits to billing-level accuracy, this revenue grade split-core current transformer opens around a conductor that is already in place, so no circuit has to be disconnected to fit it. The 333 mV output pairs with Dent PowerScout FLEX and HD meters, and rated accuracy holds to ±0.3% for energy and demand submetering. Features a window size of 1.25" and offers a 400A amp rating.
Features
Applications
| Key Specifications | |
| Window Size | 1.25" (3.20 cm) |
| Current Rating | 400A |
| Current Range | 4 to 600A |
| Output | 333 mV at rated current |
| Accuracy | ±0.3% at rated current (typical) |
| Phase Error | <0.2° at rated current (typical) |
| Accuracy Class | IEC 61869-2 Class 0.2 IEEE C57.13 Class 0.3 |
| Electrical | |
| Output | 333 mV at rated current |
| Wire Polarity | White = Hi, positive (+) Black = Low, negative (-) |
| Frequency Range | 50 to 400 Hz |
| Mechanical | |
| Case Material | 120°C UL Recognized Plastic |
| Leads | 8' (2.4 m), twisted pair, 18 AWG, 600V rated |
| Operating Temperature | -40 to 158°F (-40 to 70°C) |
| Safety | |
| Working Voltage | 600 VAC, Category III |
| Dielectric Strength | 5400 VAC |
| Certification | UL Listed to UL 2808 CAN/UL 2808 CSA STD C22.2 No. 61010-1 |
| Key Specifications | |
| Window Size | 1.25" (3.20 cm) |
| Current Rating | 400A |
| Current Range | 4 to 600A |
| Output | 333 mV at rated current |
| Accuracy | ±0.3% at rated current (typical) |
| Phase Error | <0.2° at rated current (typical) |
| Accuracy Class | IEC 61869-2 Class 0.2 IEEE C57.13 Class 0.3 |
| Electrical | |
| Output | 333 mV at rated current |
| Wire Polarity | White = Hi, positive (+) Black = Low, negative (-) |
| Frequency Range | 50 to 400 Hz |
| Mechanical | |
| Case Material | 120°C UL Recognized Plastic |
| Leads | 8' (2.4 m), twisted pair, 18 AWG, 600V rated |
| Operating Temperature | -40 to 158°F (-40 to 70°C) |
| Safety | |
| Working Voltage | 600 VAC, Category III |
| Dielectric Strength | 5400 VAC |
| Certification | UL Listed to UL 2808 CAN/UL 2808 CSA STD C22.2 No. 61010-1 |