Features

  • Fast and accurate O2, CO (0-4,000 ppm), T-stack/air temperature and draft/pressure measurements
  • On-screen "hotspot finder" to detect the optimal measurement site
  • Nine user-selectable fuels, plus 2 custom
  • B-Smart® technology enables in-field sensor replacement with pre-calibrated CO sensors, avoiding costly downtime and inconvenience
  • Manual zero/auto-zero (CO) feature
  • High CO shut-off/protection feature
  • 2-year or 3-year O2 sensor warranty
  • As easy as 1-2-3: Select fuel type, select appliance type and then start analysis
  • Exclusive Tune-Rite™ On-Demand HVAC/R Assistant: At the touch of a button, the software monitors the combustion analysis process in real-time to deliver the most accurate analysis every time; make instant troubleshooting suggestions; and provide guidance based on live data plus typical characteristics of the combustion appliance
  • Combustion analysis should be performed only after combustion para-meters indicate that the appliance has reached "steady-state" operating conditions. Steady-state can be gauged by three things: the change in temperature of combustion products in the vent system; the change in the percentage of oxygen in the flue gas mix, which assists in determining if there is excess air or excess fuel in the combustion process; the change in carbon monoxide (CO) over time - CO levels will spike during the initial fire which is normal, but they should normalize to a lower output as steady-state is reached
  • Tune-Rite™ software eliminates the guesswork commonly involved in determining steady-state by showing you a live graphical representation of all combustion parameters as they settle into a steady-state condition
  • Measured values of oxygen, stack temperature and carbon monoxide are compared to typical values for the equipment under optimum conditions
  • Programmed into the Tune-Rite™ software typical ranges for oxygen, stack temperature and carbon monoxide based on the fuel and equipment type which vary depending on the heating equipment and fuel type
  • Typical ranges can be seen in an easy-to-read bar graph format, along with the current values. Green, red and yellow indicators show whether the readings are in range (green), out of range (red), or unstable (yellow)
  • TuneRite™ software recommends possible causes for out-of-range measurements - and it will display a prioritized list of most likely potential issues to investigate
  • Using your saved "As Found" and "As Left" readings, Tune-Rite™ generates a comprehensive leave-behind service report showing the homeowner what was inspected, adjusted or repaired
  • Print stored data (100 records) and data download via USB with Fyrite® User Software

Bacharach 0024-1492 Specifications

-4 to 600°F (-20 to 316°C) -4 to 1202°F (-20 to 650° ) 0.0 to 20.9% 0 to 4,000 ppm -40 to +40 INWC (100 mBar) 0.1 to 100% 0.1 to a fuel dependent max.value in percent 0 to 250% Natural Gas, Oil #2, Oil #4, Oil #6, Propane, Coal, Wood, Kerosene, B5 (+ 2 custom) 4 AA alkaline batteries (incl.), universal power adapter or USB cable 8.0 x 3.6 x 2.3" (203 x 91 x 58mm)/16 oz (0.45kg)
Combustion Air Temp.:
Flue Gas Temperature:
Oxygen (O2):
Carbon Monoxide (CO):
Draft/Differential Pressure:
Calculated Ranges
Combustion Efficiency:
Carbon Dioxide (CO2):
Carbon Monoxide (air free): 0 to 9,999 ppm 0 to 9,999 ppm
Excess Air:
User-Selectable Fuels:
Power Supply:
Dimensions:

What's included with the Bacharach 0024-1492

  • Residential Combustion Analyzer
  • Probe
  • Spare Filters
  • Protective Rubber Boot
  • IrDA Printer
  • USB Cable
  • Fyrite® User Software
  • 8 'AA' Alkaline Batteries
  • Hard Carrying Case

Bacharach 0024-1492 Offers

Features

  • Fast and accurate O2, CO (0-4,000 ppm), T-stack/air temperature and draft/pressure measurements
  • On-screen "hotspot finder" to detect the optimal measurement site
  • Nine user-selectable fuels, plus 2 custom
  • B-Smart® technology enables in-field sensor replacement with pre-calibrated CO sensors, avoiding costly downtime and inconvenience
  • Manual zero/auto-zero (CO) feature
  • High CO shut-off/protection feature
  • 2-year or 3-year O2 sensor warranty
  • As easy as 1-2-3: Select fuel type, select appliance type and then start analysis
  • Exclusive Tune-Rite™ On-Demand HVAC/R Assistant: At the touch of a button, the software monitors the combustion analysis process in real-time to deliver the most accurate analysis every time; make instant troubleshooting suggestions; and provide guidance based on live data plus typical characteristics of the combustion appliance
  • Combustion analysis should be performed only after combustion para-meters indicate that the appliance has reached "steady-state" operating conditions. Steady-state can be gauged by three things: the change in temperature of combustion products in the vent system; the change in the percentage of oxygen in the flue gas mix, which assists in determining if there is excess air or excess fuel in the combustion process; the change in carbon monoxide (CO) over time - CO levels will spike during the initial fire which is normal, but they should normalize to a lower output as steady-state is reached
  • Tune-Rite™ software eliminates the guesswork commonly involved in determining steady-state by showing you a live graphical representation of all combustion parameters as they settle into a steady-state condition
  • Measured values of oxygen, stack temperature and carbon monoxide are compared to typical values for the equipment under optimum conditions
  • Programmed into the Tune-Rite™ software typical ranges for oxygen, stack temperature and carbon monoxide based on the fuel and equipment type which vary depending on the heating equipment and fuel type
  • Typical ranges can be seen in an easy-to-read bar graph format, along with the current values. Green, red and yellow indicators show whether the readings are in range (green), out of range (red), or unstable (yellow)
  • TuneRite™ software recommends possible causes for out-of-range measurements - and it will display a prioritized list of most likely potential issues to investigate
  • Using your saved "As Found" and "As Left" readings, Tune-Rite™ generates a comprehensive leave-behind service report showing the homeowner what was inspected, adjusted or repaired
  • Print stored data (100 records) and data download via USB with Fyrite® User Software

Bacharach 0024-1492 Specifications

-4 to 600°F (-20 to 316°C) -4 to 1202°F (-20 to 650° ) 0.0 to 20.9% 0 to 4,000 ppm -40 to +40 INWC (100 mBar) 0.1 to 100% 0.1 to a fuel dependent max.value in percent 0 to 250% Natural Gas, Oil #2, Oil #4, Oil #6, Propane, Coal, Wood, Kerosene, B5 (+ 2 custom) 4 AA alkaline batteries (incl.), universal power adapter or USB cable 8.0 x 3.6 x 2.3" (203 x 91 x 58mm)/16 oz (0.45kg)
Combustion Air Temp.:
Flue Gas Temperature:
Oxygen (O2):
Carbon Monoxide (CO):
Draft/Differential Pressure:
Calculated Ranges
Combustion Efficiency:
Carbon Dioxide (CO2):
Carbon Monoxide (air free): 0 to 9,999 ppm 0 to 9,999 ppm
Excess Air:
User-Selectable Fuels:
Power Supply:
Dimensions:

What's included with the Bacharach 0024-1492

  • Residential Combustion Analyzer
  • Probe
  • Spare Filters
  • Protective Rubber Boot
  • IrDA Printer
  • USB Cable
  • Fyrite® User Software
  • 8 'AA' Alkaline Batteries
  • Hard Carrying Case