AEMC MN379T AC Current Probe with 10' BNC lead, 0.005 to 5 A, 0.1 to 100 A

Model: MN379T | Order No: 2153.02 | UPC: 685338030440

AEMC MN379T AC Current Probe with 10' BNC lead, 0.005 to 5 A, 0.1 to 100 A

Model: MN379T | Order No: 2153.02 | UPC: 685338030440

Features a current range of 0.005 to 5 A, 0.1 to 100 A, along with a 10' (3 m) lead with BNC output.

Features a current range of 0.005 to 5 A, 0.1 to 100 A, along with a 10' (3 m) lead with BNC output.

Sale Price $312.55 USD
Regular Price $329.00 USD
Availability 2 to 3 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your MN379T AC Current Probe with 10' BNC lead

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your MN379T AC Current Probe with 10' BNC lead

AEMC Instruments MN379T Specifications

Maximum Conductor Size 0.78" (20 mm), bus bar 20 x 5 mm
Current Range 0.005 to 5 A, 0.1 to 100 A
Measurement Range 0.005 to 6 A, 0.1 to 120 A
Output 10' (3 m) lead with BNC output
Output Signal 200 mV/A AC (1 V @ 5 A) & 10 mV/A AC (1 V @ 100 A)
Accuracy 50/60 Hz 1% @ 5 A & 1% @ 100 A
Frequency Range 40 Hz to 10 KHz
Phase Shift at 50 Hz 4° @ 5 A & 2.2° @ 100 A
Load Impedance 1 MΩ
Overload 200 A continuous
Operating Temperature 14 to 122°F (-10 to 55°C)
Storage Temperature -40 to 158°F (-40 to 70°C)
Operating Humidity 90% RH
Pollution Degree 2
Ingress Protection (IP) IP40
EMC EN 61326-1
Safety Compliance Category CAT III, EN/IEC 61010-032
Dimensions 5.37 x 2.00 x 1.18" (139 x 51 x 30 mm)
Weight 6.6 oz (180 g)
Click here for complete specifications on the AEMC Instruments MN379T

What's included with the AEMC Instruments MN379T

  • AEMC MN379T AC Current Probe with 10' BNC lead, 0.005 to 5 A, 0.1 to 100 A

AEMC Instruments MN379T Specifications

Maximum Conductor Size 0.78" (20 mm), bus bar 20 x 5 mm
Current Range 0.005 to 5 A, 0.1 to 100 A
Measurement Range 0.005 to 6 A, 0.1 to 120 A
Output 10' (3 m) lead with BNC output
Output Signal 200 mV/A AC (1 V @ 5 A) & 10 mV/A AC (1 V @ 100 A)
Accuracy 50/60 Hz 1% @ 5 A & 1% @ 100 A
Frequency Range 40 Hz to 10 KHz
Phase Shift at 50 Hz 4° @ 5 A & 2.2° @ 100 A
Load Impedance 1 MΩ
Overload 200 A continuous
Operating Temperature 14 to 122°F (-10 to 55°C)
Storage Temperature -40 to 158°F (-40 to 70°C)
Operating Humidity 90% RH
Pollution Degree 2
Ingress Protection (IP) IP40
EMC EN 61326-1
Safety Compliance Category CAT III, EN/IEC 61010-032
Dimensions 5.37 x 2.00 x 1.18" (139 x 51 x 30 mm)
Weight 6.6 oz (180 g)
Click here for complete specifications on the AEMC Instruments MN379T

What's included with the AEMC Instruments MN379T

  • AEMC MN379T AC Current Probe with 10' BNC lead, 0.005 to 5 A, 0.1 to 100 A

More AEMC Instruments Products