ACR 01-0129 SmartReader Plus 8 Data Logger

Model: ACR 01-0129 | Order No: 01-0129

ACR 01-0129 SmartReader Plus 8 Data Logger

Model: ACR 01-0129 | Order No: 01-0129

Record temperature in up to eight different locations simultaneously with this data logger. Additionally, this logger features eight channels.

Record temperature in up to eight different locations simultaneously with this data logger. Additionally, this logger features eight channels.

Your Price $1384.00 USD
Availability 2 to 3 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your ACR 01-0129 SmartReader Plus 8 Data Logger

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your ACR 01-0129 SmartReader Plus 8 Data Logger

ACR ACR 01-0129 Offers

Features

  • Eight channels
  • Monitor temperature in eight different locations
  • Use with a variety of different temperature probes

Applications

  • Food process verification
  • Pharmaceutical and/or laboratory storage
  • Transportation of temperature-sensitive goods
  • Equipment run time
  • HVAC/R system testing and balancing

ACR ACR 01-0129 Specifications

Sensor Specifications
Type NTC Thermistor - 10,000 Ω at 77°F (25°C)
Range -40 to 158°F (-40 to 70°C)
Accuracy ±0.3°F over the range of 32 to 158°F (±0.2 over the range of 0 to 70°C)
Resolution 0.05°F (0.03°C) at 25°C
Better than 0.12°F (0.07°C) between -13 and 158°F (-25 and 70°C)
Better than 0.23°F (0.13°C) between -40 and -13°F (-40 and -25°C)
General Specifications
Number of Channels Eight
Sampling Rates User selectable rates from 25 per second to once every eight hours
Memory Size 32 KB
128 KB
Software Requirements TrendReader® Standard 2
PC Requirements IBM PC or 100% compatible with at least one free serial port
2 MB of RAM memory
2 MB of hard disk space
Operating Limits -40 to 158°F (-40 to 70°C) and 0 to 95% RH (non-condensing)
Sampling Methods Continuous (First-in, first-out)
Stop when full (Fill-then-stop)
Clock Accuracy ±2 seconds per day
Mounting Magnetic backing or locking eyelet
Resolution 12-bit (1 part in 4096)
Battery 3.6 V Lithium
Case Material Noryl® plastic
Dimensions 4.2 x 2.9 x 0.9" (107 x 74 x 22 mm)
Weight 3.75 oz (110 g)
Click here for complete specifications on the ACR ACR 01-0129

What's included with the ACR ACR 01-0129

  • ACR 01-0129 SmartReader Plus 8 Data Logger

Click on a category to view a selection of compatible accessories with the ACR 01-0129 SmartReader Plus 8 Data Logger.

ACR Fast Sampling Battery Pack BP-101 ACR 01-0078
Portable power supply for SmartReader Plus data loggers to allow them to sample faster than 8 seconds.




ACR 35-0000 Therm Penetration Probe - Low Temp ACR 35-0000
Stainless steel, 3 1/2in penetration probe w/handle. Thermistor type. Range: -60 to 55°C (-75 to 130°F). Length: 10ft (3 meters).




ACR 35-0001 Thermal Probe - General Purpose Temperature ACR 35-0001
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 35-0002 Therm-Probe - GP Tip - 80C - SR SRP ACR 35-0002
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: 10 to 170°C (50 to 335°F). Length: 20ft (6 meters).




ACR 35-0003 Thermal Probe - Oven Temperature ACR 35-0003
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: 70 to 255°C (155 to 490°F). Length: 20ft (6 meters).




ACR 35-0020 Skin Surface Thermal Probe - Human Temperature ACR 35-0020
Stainless steel, 1/3 X 9/64in probe. Thermistor type. Range: 20 to 40°C (68 to 104°F). Length: 5ft (1.5 meters).




ACR 35-0025 Pipe Surface Thermal Probe - General Purpose ACR 35-0025
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 01-0171 SmartReader Plus Display Module ACR 01-0171
Portable Real-time Display Module for any SmartReader Plus Data Logger (2 AA batteries and 1 foot cable included).




ACR 01-0168 Alarm Module - 100 - EU ACR 01-0168
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 240V Cont. Europe power supply for SmartReader Plus loggers.




ACR 01-0098 Network Y Splitter - Stereo (YA-200) ACR 01-0098
Allows a SmartReader Plus logger to be added to an ACR-stereo type network. 1 male and 2 female ends. Includes 1ft male to male adapter cable.




ACR 01-0167 Alarm Module - 100 - NA ACR 01-0167
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 120V NA power supply for SmartReader Plus loggers.




ACR 01-0165 Net Fast Sample Power Supply - 120V N A ACR 01-0165
120V AC to 5V DC power supply for SmartReader Plus networks with a minimum of three loggers or >50ft of network cable. Includes inYin splitter (YA-200).




ACR 01-0057 Weatherproof Logger Box ACR 01-0057
NEMA 4X clear-faced weatherproof box for all ACR loggers, Size: 18 x 13 x 10cm (7 x 5 x 4").




ACR Systems SC-100 General Purpose Logger Storage Case ACR 01-0106
General Purpose Logger Storage Case, Briefcase style, locking, customizable logger and accessory storage case.




ACR 01-0077 Logger-PC Interface Cable (IC-101) ACR 01-0077
9-pin PC serial port to logger interface cable. Compatible with SmartReader and SmartReader Plus loggers.




ACR 01-0088 Logger-PC Interface Cable, 4' ACR 01-0088
Connect the SmartReader Plus data logger to PC computer through a USB port with this interface cable which measures 4' (1.22 m). In addition, this interface cable has a 0.138" (3.5 mm) stereo jack connection.




ACR 29-0004 Terminal Block - 11 Pin ACR 29-0004
11-pin female teminal block for SmartReader/SmartReader Plus sensor inputs.




ACR ACR 01-0129 Offers

Features

  • Eight channels
  • Monitor temperature in eight different locations
  • Use with a variety of different temperature probes

Applications

  • Food process verification
  • Pharmaceutical and/or laboratory storage
  • Transportation of temperature-sensitive goods
  • Equipment run time
  • HVAC/R system testing and balancing

ACR ACR 01-0129 Specifications

Sensor Specifications
Type NTC Thermistor - 10,000 Ω at 77°F (25°C)
Range -40 to 158°F (-40 to 70°C)
Accuracy ±0.3°F over the range of 32 to 158°F (±0.2 over the range of 0 to 70°C)
Resolution 0.05°F (0.03°C) at 25°C
Better than 0.12°F (0.07°C) between -13 and 158°F (-25 and 70°C)
Better than 0.23°F (0.13°C) between -40 and -13°F (-40 and -25°C)
General Specifications
Number of Channels Eight
Sampling Rates User selectable rates from 25 per second to once every eight hours
Memory Size 32 KB
128 KB
Software Requirements TrendReader® Standard 2
PC Requirements IBM PC or 100% compatible with at least one free serial port
2 MB of RAM memory
2 MB of hard disk space
Operating Limits -40 to 158°F (-40 to 70°C) and 0 to 95% RH (non-condensing)
Sampling Methods Continuous (First-in, first-out)
Stop when full (Fill-then-stop)
Clock Accuracy ±2 seconds per day
Mounting Magnetic backing or locking eyelet
Resolution 12-bit (1 part in 4096)
Battery 3.6 V Lithium
Case Material Noryl® plastic
Dimensions 4.2 x 2.9 x 0.9" (107 x 74 x 22 mm)
Weight 3.75 oz (110 g)
Click here for complete specifications on the ACR ACR 01-0129

What's included with the ACR ACR 01-0129

  • ACR 01-0129 SmartReader Plus 8 Data Logger

Click on a category to view a selection of compatible accessories with the ACR 01-0129 SmartReader Plus 8 Data Logger.

ACR Fast Sampling Battery Pack BP-101 ACR 01-0078
Portable power supply for SmartReader Plus data loggers to allow them to sample faster than 8 seconds.




ACR 35-0000 Therm Penetration Probe - Low Temp ACR 35-0000
Stainless steel, 3 1/2in penetration probe w/handle. Thermistor type. Range: -60 to 55°C (-75 to 130°F). Length: 10ft (3 meters).




ACR 35-0001 Thermal Probe - General Purpose Temperature ACR 35-0001
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 35-0002 Therm-Probe - GP Tip - 80C - SR SRP ACR 35-0002
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: 10 to 170°C (50 to 335°F). Length: 20ft (6 meters).




ACR 35-0003 Thermal Probe - Oven Temperature ACR 35-0003
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: 70 to 255°C (155 to 490°F). Length: 20ft (6 meters).




ACR 35-0020 Skin Surface Thermal Probe - Human Temperature ACR 35-0020
Stainless steel, 1/3 X 9/64in probe. Thermistor type. Range: 20 to 40°C (68 to 104°F). Length: 5ft (1.5 meters).




ACR 35-0025 Pipe Surface Thermal Probe - General Purpose ACR 35-0025
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 01-0171 SmartReader Plus Display Module ACR 01-0171
Portable Real-time Display Module for any SmartReader Plus Data Logger (2 AA batteries and 1 foot cable included).




ACR 01-0168 Alarm Module - 100 - EU ACR 01-0168
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 240V Cont. Europe power supply for SmartReader Plus loggers.




ACR 01-0098 Network Y Splitter - Stereo (YA-200) ACR 01-0098
Allows a SmartReader Plus logger to be added to an ACR-stereo type network. 1 male and 2 female ends. Includes 1ft male to male adapter cable.




ACR 01-0167 Alarm Module - 100 - NA ACR 01-0167
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 120V NA power supply for SmartReader Plus loggers.




ACR 01-0165 Net Fast Sample Power Supply - 120V N A ACR 01-0165
120V AC to 5V DC power supply for SmartReader Plus networks with a minimum of three loggers or >50ft of network cable. Includes inYin splitter (YA-200).




ACR 01-0057 Weatherproof Logger Box ACR 01-0057
NEMA 4X clear-faced weatherproof box for all ACR loggers, Size: 18 x 13 x 10cm (7 x 5 x 4").




ACR Systems SC-100 General Purpose Logger Storage Case ACR 01-0106
General Purpose Logger Storage Case, Briefcase style, locking, customizable logger and accessory storage case.




ACR 01-0077 Logger-PC Interface Cable (IC-101) ACR 01-0077
9-pin PC serial port to logger interface cable. Compatible with SmartReader and SmartReader Plus loggers.




ACR 01-0088 Logger-PC Interface Cable, 4' ACR 01-0088
Connect the SmartReader Plus data logger to PC computer through a USB port with this interface cable which measures 4' (1.22 m). In addition, this interface cable has a 0.138" (3.5 mm) stereo jack connection.




ACR 29-0004 Terminal Block - 11 Pin ACR 29-0004
11-pin female teminal block for SmartReader/SmartReader Plus sensor inputs.




More ACR Products