ACI ASENSE-R-LCD-REL Room Carbon Dioxide Sensor, 0 to 2,000 ppm, relay output

Model: ASENSE-R-LCD-REL | Order No: 130530

ACI ASENSE-R-LCD-REL Room Carbon Dioxide Sensor, 0 to 2,000 ppm, relay output

Model: ASENSE-R-LCD-REL | Order No: 130530

Driving demand-controlled ventilation from measured occupancy rather than a fixed schedule, this room carbon dioxide sensor reads 0 to 2,000 ppm and reports over 0-10 V DC and 4-20 mA. An on-board relay switches a fan or damper directly, so a single space can be controlled without a building controller in between, and the LCD shows the current level to anyone in the room.

Driving demand-controlled ventilation from measured occupancy rather than a fixed schedule, this room carbon dioxide sensor reads 0 to 2,000 ppm and reports over 0-10 V DC and 4-20 mA. An on-board relay switches a fan or damper directly, so a single space can be controlled without a building controller in between, and the LCD shows the current level to anyone in the room.

Sale Price $449.29 USD
Regular Price $856.00 USD
Availability 2 to 3 Weeks
Quantity

ACI ASENSE-R-LCD-REL Offers

The ASENSE Room series monitors the carbon dioxide (CO2) levels in commercial, school, and office type environments. The concentration of CO2 is a strong indication of the overall indoor air quality. The ASENSE Series is based on a single beam non-dispersive infrared technology and is a cost-optimized solution for the climate control of buildings and other processes. In addition, ABC software eliminates the need for manual calibration.

Features

  • Drives demand-controlled ventilation from measured occupancy rather than a schedule
  • On-board relay switches a fan or damper directly
  • 0-10 V DC and 4-20 mA outputs
  • LCD shows the current level to anyone in the space
  • Temperature output from the same housing

Applications

  • Commercial office buildings
  • Gymnasiums
  • Shopping malls
  • Auditoriums
  • Theaters
  • Hospitals & schools

ACI ASENSE-R-LCD-REL Specifications

Sensing Range CO2: Temperature: 0 to 2000 ppm | -4 to 140°F (-20 to 60°C)
Accuracy CO21: Temperature: ±30 ppm and ±3% of reading | ±1.8°F (1°C)
Annual Zero Drift <± 0.3% of measurement range
Extended Range Accuracy > 2,000 PPM ± 30 ppm and ± 5% of reading
Relay Deadband/Hysteresis 100 ppm (factory set)
Repeatability ±20 ppm ±1% of measured value
Display (Optional) 4 digits, 7 segments LCD with ppm indicator
Output (Temperature) 0/2 to 10V, 0/4 to 20 mA, 32 to 122°F (0 to 50°C)
Outputs Output 1 (CO2): 0/2 to 10V, 0/4 to 20 mA, 0 to 2000 ppm
Relay (Optional) Output 3: N.O. or N.C. rated 0.5A @ 125 V AC; 1A @ 24 V DC
Relay Durability Mechanical: 5,000,000 operations minimum (at 36,000 operations/hr)
Relay Trip Point 1000 ppm (factory set)
Power Consumption <1W
Supply Voltage 24 V AC/VDC ±20%; 50/60 Hz, 10.5 to 40 V DC maximum (Half-wave rectified)
Wiring Connections 0.00232"2 (1.5 mm2) screw terminals
Calibration Senseair ABC algorithm (Automatic Baseline Correction)
Coverage Area 7500 sq. ft. maximum
Electrical 100,000 operations minimum (under rated load, at 1,800 operations/hr)
Extended CO2 Ranges Up to 10,000 ppm (factory set or programming cable required)
Operating Environment Residential, commercial and industrial spaces
Operating Pressure +1.6% per 0.145 psi (1 kPa) deviation from normal pressure (1 atmosphere = 14.7 psi (101.3 kPa))
Operating RH 0 to 85% RH Non-condensing
Self-Diagnostics Complete function check, yellow LED; LCD error indication (display model only)
Sensing Method Single beam Non-dispersive Infrared (NDIR)
Sensor Life >15 years
Storage Standard Versions: -40 to 158°F (-40 to 70°C) | LCD Versions: -4 to 122°F (-20 to 50°C) 0 to 85% RH Non-condensing
Warm-Up Time <5 minutes (@ full specs 15 minutes)
Operating Temperature 32°F to 122°F (0°C to 50°C)
Enclosure ABS, Flammability Rating UL94-HB
Mounting Height 4 to 6' off the floor
Product Dimensions (L x W x H) 4.70 x 3.20 x 1.20" (119.4 x 81.3 x 30.5 mm)
Product Weight 0.25 lbs (113 g)
Agency Approvals EMC Directive 2014/30/EC, RoHS Directive 2011/65/EU & RoHS 3 Directive 2015/863/EU
Click here for complete specifications on the ACI ASENSE-R-LCD-REL

What's included with the ACI ASENSE-R-LCD-REL

  • Room Carbon Dioxide Sensor
  • Five-Year Warranty

ACI ASENSE-R-LCD-REL Offers

The ASENSE Room series monitors the carbon dioxide (CO2) levels in commercial, school, and office type environments. The concentration of CO2 is a strong indication of the overall indoor air quality. The ASENSE Series is based on a single beam non-dispersive infrared technology and is a cost-optimized solution for the climate control of buildings and other processes. In addition, ABC software eliminates the need for manual calibration.

Features

  • Drives demand-controlled ventilation from measured occupancy rather than a schedule
  • On-board relay switches a fan or damper directly
  • 0-10 V DC and 4-20 mA outputs
  • LCD shows the current level to anyone in the space
  • Temperature output from the same housing

Applications

  • Commercial office buildings
  • Gymnasiums
  • Shopping malls
  • Auditoriums
  • Theaters
  • Hospitals & schools

ACI ASENSE-R-LCD-REL Specifications

Sensing Range CO2: Temperature: 0 to 2000 ppm | -4 to 140°F (-20 to 60°C)
Accuracy CO21: Temperature: ±30 ppm and ±3% of reading | ±1.8°F (1°C)
Annual Zero Drift <± 0.3% of measurement range
Extended Range Accuracy > 2,000 PPM ± 30 ppm and ± 5% of reading
Relay Deadband/Hysteresis 100 ppm (factory set)
Repeatability ±20 ppm ±1% of measured value
Display (Optional) 4 digits, 7 segments LCD with ppm indicator
Output (Temperature) 0/2 to 10V, 0/4 to 20 mA, 32 to 122°F (0 to 50°C)
Outputs Output 1 (CO2): 0/2 to 10V, 0/4 to 20 mA, 0 to 2000 ppm
Relay (Optional) Output 3: N.O. or N.C. rated 0.5A @ 125 V AC; 1A @ 24 V DC
Relay Durability Mechanical: 5,000,000 operations minimum (at 36,000 operations/hr)
Relay Trip Point 1000 ppm (factory set)
Power Consumption <1W
Supply Voltage 24 V AC/VDC ±20%; 50/60 Hz, 10.5 to 40 V DC maximum (Half-wave rectified)
Wiring Connections 0.00232"2 (1.5 mm2) screw terminals
Calibration Senseair ABC algorithm (Automatic Baseline Correction)
Coverage Area 7500 sq. ft. maximum
Electrical 100,000 operations minimum (under rated load, at 1,800 operations/hr)
Extended CO2 Ranges Up to 10,000 ppm (factory set or programming cable required)
Operating Environment Residential, commercial and industrial spaces
Operating Pressure +1.6% per 0.145 psi (1 kPa) deviation from normal pressure (1 atmosphere = 14.7 psi (101.3 kPa))
Operating RH 0 to 85% RH Non-condensing
Self-Diagnostics Complete function check, yellow LED; LCD error indication (display model only)
Sensing Method Single beam Non-dispersive Infrared (NDIR)
Sensor Life >15 years
Storage Standard Versions: -40 to 158°F (-40 to 70°C) | LCD Versions: -4 to 122°F (-20 to 50°C) 0 to 85% RH Non-condensing
Warm-Up Time <5 minutes (@ full specs 15 minutes)
Operating Temperature 32°F to 122°F (0°C to 50°C)
Enclosure ABS, Flammability Rating UL94-HB
Mounting Height 4 to 6' off the floor
Product Dimensions (L x W x H) 4.70 x 3.20 x 1.20" (119.4 x 81.3 x 30.5 mm)
Product Weight 0.25 lbs (113 g)
Agency Approvals EMC Directive 2014/30/EC, RoHS Directive 2011/65/EU & RoHS 3 Directive 2015/863/EU
Click here for complete specifications on the ACI ASENSE-R-LCD-REL

What's included with the ACI ASENSE-R-LCD-REL

  • Room Carbon Dioxide Sensor
  • Five-Year Warranty

More ACI Products