ACI A Series Room Temperature Transmitter, 1,000 ohm RTD, 4-20 mA output

Model: A/TT1K-R2-4 | Order No: 130557

ACI A Series Room Temperature Transmitter, 1,000 ohm RTD, 4-20 mA output

Model: A/TT1K-R2-4 | Order No: 130557

Sending space temperature over a long cable run without signal loss, this room temperature transmitter converts a 1,000 ohm RTD reading into a 4-20 mA current loop. Two-wire termination keeps the field wiring simple, and the current signal stays immune to the voltage drop that limits a bare resistance sensor.

Sending space temperature over a long cable run without signal loss, this room temperature transmitter converts a 1,000 ohm RTD reading into a 4-20 mA current loop. Two-wire termination keeps the field wiring simple, and the current signal stays immune to the voltage drop that limits a bare resistance sensor.

Sale Price $80.55 USD
Regular Price $208.00 USD
Availability 2 to 3 Weeks
Quantity

ACI A/TT1K-R2-4 Offers

The ACI Transmitter Room Series features a two-wire, 4 to 20 mA loop powered output with optional 3-Wire voltage output signals available. All transmitters include Zero and Span adjustments for field calibration and are calibrated using NIST Certified Calibration equipment. ACI recommends the use of an 18 to 22 AWG shielded cable for all temperature transmitter installations to reduce the chances of noise being introduced onto the signal lines. The room transmitters are designed to be mounted over a standard single gang junction box or hole in the wall.

Features

  • Converts the sensor reading to a 4-20 mA loop, immune to cable voltage drop
  • Two-wire termination keeps field wiring simple
  • Suits long runs where a bare resistance sensor would read low

Applications

  • Space temperature sensing
  • Office buildings
  • Schools
  • Gyms
  • Manufacturing plants
  • Pharmaceutical
  • Hospitals
  • Data centers

ACI A/TT1K-R2-4 Specifications

Calibration Temperature Spans Minimum Temp. Span: 50°F (28°C) | Maximum Temp. Span: 200°F (93°C)
Calibrated Transmitter Accuracy | Linearity Temp. Spans < 500°F (260°C): ± 0.2%
RTD Tolerance Class | Sensor Accuracy Where |t| is the absolute valuse of temperature above or below 0°C in °C
Sensor Stability ± 0.03% after 1000 hours @ 300°C (572°F)
Set Point Accuracy 20 mA (Far Left) / 4 mA (Far Right)(RA-Reverse Acting (Optional))
Temperature Drift Temp. Spans < 100°F (38°C): ± 0.04%/°F | Temp. Spans > 100°F (38°C): ± 0.02%
Warm Up Time | Warm Up Drift 10 minutes | ± 0.1%
Output Signals Current: 4 to 20 mA (2-Wire Loop Powered) | Voltage: 1 to 5 V DC or 2 to 10 V DC (3-Wires)
Override Contact Type | Contact Ratings Dry Contact "N/O" Contact | Minimum: 10 uA @ 1 V DC | Maximum: 50 mA @ 24 V DC ± 10% | 4 to 20 mA: 4 mA (Far Left) / 20 mA (Far Right)(DA-Direct Acting (Default))
Maximum Load Resistance (Terminal Voltage - 8.5 V) | 0.020 A
Supply Current 25 mA minimum
Connections | Wire Size Screw Terminal Blocks (Polarity Sensitive) | 16 AWG (1.31 mm2) to 26 AWG (0.129 mm2)
Terminal Block Torque Rating 0.37 ft-lb (0.5 N-3m) nominal
Din Standard | Temperature Coefficient DIN EN 60751 (IEC 751) | 3850 ppm / °C
Operating Humidity Range 5 to 95% RH non-condensing
Operating Temperature Range 35 to 122°F (1.5 to 50°C)
Storage Temperature Range Non-LCD:-40 to 65°C (-40 to 149°F) | LCD Display: -10 to 65°C (14 to 149°F)
Product Dimensions (L x W x H) 4.45 x 2.70 x 1.10" (113.0 x 68.6 x 27.9 mm)
Product Weight 0.13 lbs (59 g)
Agency Approvals RoHS2, WEEE
TTM100/TTM1K Certification Points 3 Point NIST: 20%, 50% & 80% of span | 5 Point NIST: 20%, 35%, 50%, 65% & 80% of span
Click here for complete specifications on the ACI A/TT1K-R2-4

What's included with the ACI A/TT1K-R2-4

  • Room Temperature Transmitter
  • Five-Year Warranty

ACI A/TT1K-R2-4 Offers

The ACI Transmitter Room Series features a two-wire, 4 to 20 mA loop powered output with optional 3-Wire voltage output signals available. All transmitters include Zero and Span adjustments for field calibration and are calibrated using NIST Certified Calibration equipment. ACI recommends the use of an 18 to 22 AWG shielded cable for all temperature transmitter installations to reduce the chances of noise being introduced onto the signal lines. The room transmitters are designed to be mounted over a standard single gang junction box or hole in the wall.

Features

  • Converts the sensor reading to a 4-20 mA loop, immune to cable voltage drop
  • Two-wire termination keeps field wiring simple
  • Suits long runs where a bare resistance sensor would read low

Applications

  • Space temperature sensing
  • Office buildings
  • Schools
  • Gyms
  • Manufacturing plants
  • Pharmaceutical
  • Hospitals
  • Data centers

ACI A/TT1K-R2-4 Specifications

Calibration Temperature Spans Minimum Temp. Span: 50°F (28°C) | Maximum Temp. Span: 200°F (93°C)
Calibrated Transmitter Accuracy | Linearity Temp. Spans < 500°F (260°C): ± 0.2%
RTD Tolerance Class | Sensor Accuracy Where |t| is the absolute valuse of temperature above or below 0°C in °C
Sensor Stability ± 0.03% after 1000 hours @ 300°C (572°F)
Set Point Accuracy 20 mA (Far Left) / 4 mA (Far Right)(RA-Reverse Acting (Optional))
Temperature Drift Temp. Spans < 100°F (38°C): ± 0.04%/°F | Temp. Spans > 100°F (38°C): ± 0.02%
Warm Up Time | Warm Up Drift 10 minutes | ± 0.1%
Output Signals Current: 4 to 20 mA (2-Wire Loop Powered) | Voltage: 1 to 5 V DC or 2 to 10 V DC (3-Wires)
Override Contact Type | Contact Ratings Dry Contact "N/O" Contact | Minimum: 10 uA @ 1 V DC | Maximum: 50 mA @ 24 V DC ± 10% | 4 to 20 mA: 4 mA (Far Left) / 20 mA (Far Right)(DA-Direct Acting (Default))
Maximum Load Resistance (Terminal Voltage - 8.5 V) | 0.020 A
Supply Current 25 mA minimum
Connections | Wire Size Screw Terminal Blocks (Polarity Sensitive) | 16 AWG (1.31 mm2) to 26 AWG (0.129 mm2)
Terminal Block Torque Rating 0.37 ft-lb (0.5 N-3m) nominal
Din Standard | Temperature Coefficient DIN EN 60751 (IEC 751) | 3850 ppm / °C
Operating Humidity Range 5 to 95% RH non-condensing
Operating Temperature Range 35 to 122°F (1.5 to 50°C)
Storage Temperature Range Non-LCD:-40 to 65°C (-40 to 149°F) | LCD Display: -10 to 65°C (14 to 149°F)
Product Dimensions (L x W x H) 4.45 x 2.70 x 1.10" (113.0 x 68.6 x 27.9 mm)
Product Weight 0.13 lbs (59 g)
Agency Approvals RoHS2, WEEE
TTM100/TTM1K Certification Points 3 Point NIST: 20%, 50% & 80% of span | 5 Point NIST: 20%, 35%, 50%, 65% & 80% of span
Click here for complete specifications on the ACI A/TT1K-R2-4

What's included with the ACI A/TT1K-R2-4

  • Room Temperature Transmitter
  • Five-Year Warranty

More ACI Products